Efficient Fault Detection Method for a Degaussing Coil System Based on an Analytical Sensitivity Formula

被引:1
|
作者
Choi, Nak-Sun [1 ]
Kim, Dong-Wook [1 ]
Yang, Chang-Seob [2 ]
Chung, Hyun-Ju [2 ]
Kim, Heung-Geun [1 ]
Kim, Dong-Hun [1 ]
机构
[1] Kyungpook Natl Univ, Dept Elect Engn, Taegu 702701, South Korea
[2] Agcy Def Dev, R&D Inst 2 6, Chang Won 645600, South Korea
关键词
diagnosis; electromagnetics; inverse problem; design sensitivity; MAGNETIZATION;
D O I
10.4283/JMAG.2013.18.2.135
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper proposes an efficient fault detection method for onboard degaussing coils which are installed to minimize underwater magnetic fields due to the ferromagnetic hull. To achieve this, the method basically uses field signals measured at specific magnetic treatment facilities instead of time-consuming numerical field solutions in a three-dimensional analysis space. In addition, an analytical design sensitivity formula and the linear property of degaussing coil fields is being exploited for detecting fault coil positions and assessing individual degaussing coil currents. Such peculiar features make it possible to yield fast and accurate results on the fault detection of degaussing coils. For foreseeable fault conditions, the proposed method is tested with a model ship equipped with 20 degaussing coils.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 50 条
  • [41] A combined method based on neural network for control system fault detection and diagnosis
    Ren, Z
    Chen, F
    Tang, XJ
    Yan, WS
    PROCEEDINGS OF THE 2000 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, 2000, : 104 - 108
  • [42] Model-based fault detection method for yaw system of wind turbine
    Zhao, Hongshan
    Dong, Yeye
    Song, Peng
    Deng, Chun
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (05): : 142 - 149
  • [43] Detection Method of Gradual Fault Signal Based on Wavelet Transform in the Dynamic System
    Du, Hailian
    Wang, Zhanfeng
    Lv, Feng
    Du, Wenxia
    FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE, PTS 1-4, 2011, 44-47 : 3790 - +
  • [44] On Fault Line Detection in Neutral Grounding System via Arc-suppression Coil Based on Fuzzy Theory
    Li, Bo
    PROCEEDINGS OF THE 31ST CHINESE CONTROL CONFERENCE, 2012, : 5250 - 5253
  • [45] Partial cloud-based evolving method for fault detection of HVAC system
    Andonovski, Goran
    Blazic, Saso
    Skrjanc, Igor
    2018 IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS (FUZZ-IEEE), 2018,
  • [46] Fault detection and isolation for output feedback system based on space geometry method
    Yandong Hou
    Ruirui Huang
    Qianshuai Cheng
    Liyang Hou
    Xiaonan Wang
    Cluster Computing, 2019, 22 : 9313 - 9321
  • [47] Fault detection method based on fuzzy comprehensive evaluation for integrated navigation system
    Liu Guo-liang
    Zhang Ying-chun
    Wang Wen-yi
    Sun Zeng-qi
    PROCEEDINGS OF 2005 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1 AND 2, 2005, : 1005 - 1007
  • [48] A New DC System Fault Detection Method Based on Improved Unbalanced Bridge
    Tan, Mingang
    Cui, Han
    Wei, Bangcheng
    Li, Chenlong
    Xu, Yan
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 419 - 423
  • [49] Fault detection and isolation for output feedback system based on space geometry method
    Hou, Yandong
    Huang, Ruirui
    Cheng, Qianshuai
    Hou, Liyang
    Wang, Xiaonan
    CLUSTER COMPUTING-THE JOURNAL OF NETWORKS SOFTWARE TOOLS AND APPLICATIONS, 2019, 22 (Suppl 4): : S9313 - S9321
  • [50] Enzyme amplification: An analytical detection system with zeptomole sensitivity.
    Bates, D
    MOLECULAR BIOLOGY OF THE CELL, 1996, 7 : 3885 - 3885