Myocardial tissue phase mapping with cine phase-contrast MR imaging: Regional wall motion analysis in healthy volunteers

被引:75
|
作者
Petersen, SE [1 ]
Jung, BA
Wiesmann, F
Selvanayagam, JB
Francis, JM
Hennig, J
Neubauer, S
Robson, MD
机构
[1] Univ Oxford, Ctr Clin Magnet Resonnance Res, Oxford, England
[2] Univ Oxford, John Radcliffe Hosp, Dept Cardiovasc Med, Oxford OX3 9DU, England
[3] Univ Oxford, John Radcliffe Hosp, Dept Biochem, Oxford OX3 9DU, England
[4] Univ Freiburg, Dept Radiol, Sect Med Phys, Freiburg, Germany
关键词
D O I
10.1148/radiol.2383041992
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To establish prospectively a database of normal three-dimensional systolic and diastolic endocardial and epicardial velocity values for all myocardial segments in healthy volunteers by using cine phase-contrast velocity magnetic resonance imaging, also called tissue phase mapping (TPM). Materials and Methods: The study was approved by the institutional ethics commit: tee and was conducted according to principles of the Declaration of Helsinki; each subject provided informed written consent. Ninety-six healthy volunteers (57 [59%] men, 39 [41%] women; mean age, 38 years 12 [standard deviation]) underwent cardiac phase-contrast imaging with a black blood segmented k-space gradient-echo sequence for the analysis of three-dimensional myocardial velocity with high spatial resolution at 1.5 T on basal, midventricular, and apical short-axis views. Eighteen consecutive volunteers were imaged twice to determine interstudy reproducibility, and intra- and interobserver variability values were analyzed. Systolic and diastolic velocity curves were analyzed for peak velocity and time to peak velocity in the radial, circumferential, and longitudinal directions, as well as for torsion rate and longitudinal strain rate. Mixed-effects models with a random intercept for volunteers were used to test differences among the three ventricular sections and the transmural, endocardial, and epicardial parameters. Results: TPM enabled reproducible assessment of myocardial velocity with small intra- and interobserver variability values. Systolic peak radial velocity was lowest at the apical level (P < .001); diastolic peak radial velocity was similar at all three myocardial levels (P = .73). As viewed from the apex, a relative counterclockwise rotation during systole was followed by a relative clockwise rotation of the apex against the base. Diastolic and systolic peak longitudinal velocity values decreased from base to apex (P < .001) - A gradient between endocardium and epicardium. was observed for radial velocity values, with greater endocardial velocity values (P < .001). Conclusion: TPM is a reproducible comprehensive modality for assessment of regional wall motion, and intra- and interobserver variability values are low.
引用
收藏
页码:816 / 826
页数:11
相关论文
共 50 条
  • [31] Influence of the area of the aqueduct and region of interest on quantification of stroke volume in healthy volunteers using phase-contrast cine magnetic resonance imaging
    Zhang, Hongri
    Yang, Haixin
    Duan, Weike
    Li, Xiaopan
    Wang, Yixin
    Cogswell, Petrice M.
    Elder, Benjamin D.
    ACTA RADIOLOGICA, 2023, 64 (04) : 1615 - 1622
  • [32] ELASTIC PROPERTIES OF TENDON AND MYOTENDINOUS TISSUE - MEASUREMENT WITH PHASE-CONTRAST MR IMAGING
    DRACE, JE
    HERFKENS, RJ
    PELC, NJ
    RADIOLOGY, 1992, 185 : 177 - 177
  • [33] HYBRID DANTE AND PHASE-CONTRAST IMAGING TECHNIQUE FOR MEASUREMENT OF 3-DIMENSIONAL MYOCARDIAL WALL-MOTION
    PERMAN, WH
    CRESWELL, LL
    WYERS, SG
    MOULTON, MJ
    PASQUE, MK
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (01): : 101 - 106
  • [34] Phase-contrast optical coherence imaging of tissue
    Jeong, K
    Turek, JJ
    Nolte, DD
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE IX, 2005, 5690 : 412 - 421
  • [35] Functional analysis of third ventriculostomy patency by quantification of CSF stroke volume by using cine phase-contrast MR imaging
    Bargalló, N
    Olondo, L
    Garcia, AI
    Capurro, S
    Caral, L
    Rumia, J
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (10) : 2514 - 2521
  • [36] VOLUMETRIC FLOW-RATES IN THE PORTAL VENOUS SYSTEM - MEASUREMENT WITH CINE PHASE-CONTRAST MR IMAGING
    BURKART, DJ
    JOHNSON, CD
    MORTON, MJ
    WOLF, RL
    EHMAN, RL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (05) : 1113 - 1118
  • [37] PHASE-CONTRAST CINE MR IMAGING FOR MEASURING SUPERIOR MESENTERIC-ARTERY BLOOD-FLOW
    LI, KC
    WHITNEY, WS
    MCDONNELL, CH
    VANDALSEM, WJ
    FREDRICKSON, J
    PELC, NJ
    RADIOLOGY, 1992, 185 : 235 - 235
  • [38] LIVER METASTASES - DETECTION BY PHASE-CONTRAST MR IMAGING
    STARK, DD
    WITTENBERG, J
    MIDDLETON, MS
    FERRUCCI, JT
    RADIOLOGY, 1986, 158 (02) : 327 - 332
  • [39] Identification of a Dural Defect with Cine Phase Contrast MR Imaging
    Fukumoto, Genki
    Kanagaki, Mitsunori
    Ishimoto, Takeshi
    Kitazumi, Kazuya
    Hara, Atsushi
    Kimura, Hiroaki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (02) : 89 - 91
  • [40] Application of phase-contrast cine magnetic resonance imaging in endoscopic aqueductoplasty
    Chen, Guoqiang
    Zheng, Jiaping
    Xiao, Qing
    Liu, Yunsheng
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (06) : 1643 - 1648