Myocardial tissue phase mapping with cine phase-contrast MR imaging: Regional wall motion analysis in healthy volunteers

被引:75
|
作者
Petersen, SE [1 ]
Jung, BA
Wiesmann, F
Selvanayagam, JB
Francis, JM
Hennig, J
Neubauer, S
Robson, MD
机构
[1] Univ Oxford, Ctr Clin Magnet Resonnance Res, Oxford, England
[2] Univ Oxford, John Radcliffe Hosp, Dept Cardiovasc Med, Oxford OX3 9DU, England
[3] Univ Oxford, John Radcliffe Hosp, Dept Biochem, Oxford OX3 9DU, England
[4] Univ Freiburg, Dept Radiol, Sect Med Phys, Freiburg, Germany
关键词
D O I
10.1148/radiol.2383041992
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To establish prospectively a database of normal three-dimensional systolic and diastolic endocardial and epicardial velocity values for all myocardial segments in healthy volunteers by using cine phase-contrast velocity magnetic resonance imaging, also called tissue phase mapping (TPM). Materials and Methods: The study was approved by the institutional ethics commit: tee and was conducted according to principles of the Declaration of Helsinki; each subject provided informed written consent. Ninety-six healthy volunteers (57 [59%] men, 39 [41%] women; mean age, 38 years 12 [standard deviation]) underwent cardiac phase-contrast imaging with a black blood segmented k-space gradient-echo sequence for the analysis of three-dimensional myocardial velocity with high spatial resolution at 1.5 T on basal, midventricular, and apical short-axis views. Eighteen consecutive volunteers were imaged twice to determine interstudy reproducibility, and intra- and interobserver variability values were analyzed. Systolic and diastolic velocity curves were analyzed for peak velocity and time to peak velocity in the radial, circumferential, and longitudinal directions, as well as for torsion rate and longitudinal strain rate. Mixed-effects models with a random intercept for volunteers were used to test differences among the three ventricular sections and the transmural, endocardial, and epicardial parameters. Results: TPM enabled reproducible assessment of myocardial velocity with small intra- and interobserver variability values. Systolic peak radial velocity was lowest at the apical level (P < .001); diastolic peak radial velocity was similar at all three myocardial levels (P = .73). As viewed from the apex, a relative counterclockwise rotation during systole was followed by a relative clockwise rotation of the apex against the base. Diastolic and systolic peak longitudinal velocity values decreased from base to apex (P < .001) - A gradient between endocardium and epicardium. was observed for radial velocity values, with greater endocardial velocity values (P < .001). Conclusion: TPM is a reproducible comprehensive modality for assessment of regional wall motion, and intra- and interobserver variability values are low.
引用
收藏
页码:816 / 826
页数:11
相关论文
共 50 条
  • [1] VALIDATION OF CINE PHASE-CONTRAST MR-IMAGING FOR MOTION ANALYSIS
    LINGAMNENI, A
    HARDY, PA
    POWELL, KA
    PELC, NJ
    WHITE, RD
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 331 - 338
  • [2] PHASE-CONTRAST CINE-MR IMAGING OF CSF DYNAMICS
    ALESSANDRINI, F
    PINNA, G
    SANTINO, P
    RIVISTA DI NEURORADIOLOGIA, 1995, 8 (03): : 383 - 398
  • [3] Flow quantification using fast cine phase-contrast MR imaging, conventional cine phase-contrast MR imaging, and Doppler sonography: In vitro and in vivo validation
    Lee, VS
    Spritzer, CE
    Carroll, BA
    Pool, LG
    Bernstein, MA
    Heinle, SK
    MacFall, JR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (04) : 1125 - 1131
  • [4] TRACKING OF CYCLIC MOTION WITH PHASE-CONTRAST CINE MR VELOCITY DATA
    PELC, NJ
    DRANGOVA, M
    PELC, LR
    ZHU, Y
    NOLL, DC
    BOWMAN, BS
    HERFKENS, RJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 339 - 345
  • [5] BRAIN MOTION - MEASUREMENT WITH PHASE-CONTRAST MR IMAGING
    ENZMANN, DR
    PELC, NJ
    RADIOLOGY, 1992, 185 (03) : 653 - 660
  • [6] Vessel wall strain with cine phase contrast MR imaging
    Wedding, KL
    Draney, MT
    Taylor, CA
    Pelc, NJ
    RADIOLOGY, 1999, 213P : 478 - 478
  • [7] COMBINED DANTE AND PHASE-CONTRAST TISSUE TAGGING - HYBRID IMAGING TECHNIQUE FOR DETECTION OF MYOCARDIAL WALL MOTION AND STRAIN ANALYSIS
    PERMAN, WH
    CRESWELL, LL
    WYERS, SG
    PASQUE, MK
    RADIOLOGY, 1992, 185 : 302 - 302
  • [8] PHASE-CONTRAST CINE MR-IMAGING DETECTION OF THORACIC AORTA DISSECTION
    SILVERMAN, JM
    HERFKENS, RJ
    RAISSI, S
    CHAUX, A
    KASS, R
    BLANCHE, C
    RADIOLOGY, 1995, 197 : 418 - 418
  • [9] CHRONIC MESENTERIC ISCHEMIA - EVALUATION WITH PHASE-CONTRAST CINE MR-IMAGING
    LI, KCP
    WHITNEY, WS
    MCDONNELL, CH
    FREDRICKSON, JO
    PELC, NJ
    DALMAN, RL
    JEFFREY, RB
    RADIOLOGY, 1994, 190 (01) : 175 - 179
  • [10] Cine phase-contrast MR imaging in the tailored evaluation of congenital heart diseases
    Ho, VB
    Kinney, JB
    Sahn, DJ
    RADIOLOGY, 1996, 201 : 1327 - 1327