摘要
The measurement of salt levels in blood assume an essential part in the control of numerous real capacities and is contained in body liquids that vehicle oxygen and supplements. We have performed a pilot work to verify the accuracy of blood salt levels obtained through a Fourier domain optical coherence tomography (FD-OCT) simulation approach using MATLAB experimentally with spectral-domain OCT (SD-OCT). Different concentrations of salt were admixed in water, blood plasma and whole blood samples have been investigated to monitor the effect of salt on whole blood using optical coherence tomography. We have successfully measured the viscosity of these samples by measuring the autocorrelation function based on M-mode data under dynamic light scattering in the Brownian motion regime. The effect of the shape of erythrocytes/aggregations on the signal in case of the whole blood sample has been explored exclusively. Conclusively, the diffusion of salt changes the refractive indices of mediums and increases aggregation of erythrocytes and forms rouleaux in whole blood. Autocorrelation functions in the simulation approach of optical coherence tomography were processed by applying inverse Fourier transforms to get the depth profiles of the characteristic signal. The relation between concentrations of salt and viscosity of signal yield the straight-line regressions.
引用
收藏
页码:77 / 94
页数:18
相关论文
共 50 条
  • [31] Enhanced spectral-domain optical coherence tomography (SD-OCT) using in situ ultrasonic virtual tunable optical waveguides
    Karimi, Yasin
    Yang, Hang
    Liu, Junze
    Park, B. Hyle
    Chamanzar, Maysamreza
    OPTICS EXPRESS, 2022, 30 (19): : 34256 - 34275
  • [32] Analysis of macular ganglion cell complex (GCC) with spectral-domain optical coherence tomography (SD-OCT) in glaucoma
    Renard, J. -P.
    Fenolland, J. -R.
    El Chehab, H.
    Francoz, M.
    Marill, A. -M.
    Messaoudi, R.
    Delbarre, M.
    Marechal, M.
    Michel, S.
    Giraud, J. -M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2013, 36 (04): : 299 - 309
  • [33] SCREENING OF GLAUCOMA USING SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY (SD-OCT) IN AN ELDERLY POPULATION: THE ALIENOR STUDY
    Schweitzer, Cedric
    Le Goff, Melanie
    Korobelnik, Jean-Francois
    Rougier, Marie B.
    Delyfer, Marie-Noelle
    Dartigues, Jean-Francois
    DelCourt, Cecile
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [34] Subretinal thickening is a novel finding in Stargardt disease using Spectral Domain-Optical Coherence Tomography (SD-OCT)
    Light, Jacob G.
    Sun, Kai
    Handa, James T.
    Ebrahimi, Katayoon B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [35] Nerve fiber layer thickness in a Latin American population using spectral domain optical coherence tomography (SD-OCT)
    Roca, Daniela
    Alejandra Cortes, Diana Alejandra
    Camila Plata, Maria
    Gutierrez, Sergio
    Rodriguez, Francisco J.
    Belalcazar-Rey, Sandra
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [36] Distribution of Gold Nanorods Monitored With Spectral-Domain Optical Coherence Tomography (SD-OCT) After Intravitreal Injection
    Gabriele, M. L.
    McKenna, K. C.
    Schuman, J. S.
    Ishikawa, H.
    Franks, J.
    Sun, M.
    Halfter, W.
    Kagemann, L.
    Wollstein, G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [37] Using Asymmetry Analysis to Reduce Normal Variability of Spectral Domain Optical Coherence Tomography (SD-OCT) Macular Thickne
    Alluwimi, Muhammed
    Swanson, William
    Malinovsky, Victor
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [38] Assessment of retinal atrophy in mixed breed dogs using spectral domain optical coherence tomography (SD-OCT) and electroretinography
    Balicki, Ireneusz
    Szadkowski, Mateusz
    Balicka, Agnieszka
    Lew, Marcin
    Trbolova, Alexandra
    ACTA VETERINARIA HUNGARICA, 2024, 72 (02) : 80 - 98
  • [39] Assessment of the use of spectral domain optical coherence tomography (SD-OCT) for evaluation of the healthy and pathological cornea in dogs and cats
    Famose, Frank
    VETERINARY OPHTHALMOLOGY, 2014, 17 (01) : 12 - 22
  • [40] Non-Invasive Assessment of Aqueous Outflow in Collector Channels by Spectral Domain Optical Coherence Tomography (SD-OCT)
    Kagemann, L.
    Wollstein, G.
    Ishikawa, H.
    Bilonick, R. A.
    Brennen, P. M.
    Gabriele, M. L.
    Folio, L. S.
    Schuman, J. S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)