摘要
A Doppler flow meter was developed, consisting of a PC and a control card for two Doppler sensors to be fixed on skin. From the measured Doppler signals a power spectrum is calculated by a software FFT. In contrast to usual laser Doppler flow measurements in skin, which provide only a mean flow, a flow spectrum is calculated with the assumption of an isotropic distribution of the directions of the velocity of the erythrocytes and irradiation vectors in the skin. Up to four partial flows (integral over a certain frequency region of the flow spectrum) are displayed on the screen simultaneously with a resolution in time < 10 ms. The frequency span can be set independently for each few. Corresponding to low and high Doppler frequencies the flows show different behavior and provide the possibility to distinguish between the flow in the superficial dermal plexus and larger micro-capillaries. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:257 / 264
页数:8
相关论文
共 50 条
  • [21] Commentary: Multiple laser doppler flowmetry probes increase the reproducibility of skin blood flow measurements
    Guigui, Alicia
    Loader, Jordan
    Bellier, Alexandre
    Roustit, Matthieu
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [22] Response of skin blood volume, velocity and flow to local warming in newborns, measured by laser Doppler flowmetry
    Takayanagi, T
    Fukuda, M
    Nakazawa, M
    Tanaka, S
    Yoshinaga, M
    Takayanagi, T
    PEDIATRICS INTERNATIONAL, 1999, 41 (06) : 624 - 630
  • [23] LASER DOPPLER MEASUREMENTS OF BLOOD VELOCITY IN HUMAN RETINAL-VESSELS
    FEKE, GT
    RIVA, CE
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (04) : 526 - 531
  • [24] SKIN BLOOD FLOW ASSESSED BY LASER DOPPLER IN PATIENTS WITH SHOCK
    Stringari, G.
    Cortes, D. Orbegozo
    Gottin, L.
    De Backer, D.
    Creteur, J.
    Vincent, J. L.
    INTENSIVE CARE MEDICINE, 2014, 40 : S47 - S48
  • [25] Velocity bias corrections of laser Doppler anemometry for separated flow measurements
    Rinoie, K
    Hata, K
    Shirai, Y
    Sunada, Y
    TRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, 1999, 42 (137) : 147 - 149
  • [26] A LASER DOPPLER SCANNER FOR IMAGING BLOOD-FLOW IN SKIN
    ESSEX, TJH
    BYRNE, PO
    JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (03): : 189 - 194
  • [27] NONINVASIVE VERSUS INVASIVE DOPPLER RENAL BLOOD VELOCITY AND FLOW MEASUREMENTS
    GREENE, ER
    AVASTHI, PS
    VOYLES, WF
    SEIGEL, RS
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (03) : 302 - 307
  • [28] MEASUREMENTS OF CORONARY SINUS BLOOD-FLOW VELOCITY BY DOPPLER CATHETERS
    TEBBENJOHANNS, J
    NITSCH, J
    LUDERITZ, B
    ZEITSCHRIFT FUR KARDIOLOGIE, 1992, 81 (03): : 170 - 175
  • [29] MODEL FOR LASER DOPPLER MEASUREMENTS OF BLOOD-FLOW IN TISSUE
    BONNER, R
    NOSSAL, R
    APPLIED OPTICS, 1981, 20 (12) : 2097 - 2107
  • [30] A novel laser Doppler flowmeter for pulpal blood flow measurements
    Zang, DY
    Millerd, JE
    WilderSmith, PBB
    Arrastia, AMA
    LASERS IN DENTISTRY II, PROCEEDINGS OF, 1996, 2672 : 21 - 26