A scenario for high accuracy τ mass measurement at BEPC-II

被引:9
|
作者
Achasov, M. N. [1 ]
Blinov, V. E. [1 ]
Cai Xiao [2 ]
Fu Cheng-Dong [2 ]
Harris, F. A. [3 ]
Liu, Q. [3 ]
Mo Xiao-Hu [2 ]
Muchnoi, N. Yu [1 ]
Nikolaev, I. B. [1 ]
Qin Qing [2 ]
Shamov, A. G. [1 ]
Todyshev, K. Yu [1 ]
Wang Yi-Fang [2 ]
Zhang Jian-Yong [2 ]
机构
[1] Russian Acad Sci, Budker Inst Nucl Phys, Siberian Branch, Novosibirsk 630090, Russia
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[3] Univ Hawaii, Honolulu, HI 96822 USA
基金
中国国家自然科学基金;
关键词
tau mass; scan optimization uncertainty; COLLIDER; LEPTON; SYSTEM;
D O I
10.1088/1674-1137/36/7/001
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Scenarios for the T mass measurement at the upgraded Beijing Electron-Positron Collider (BEPC-II) are studied. A nested minimization procedure is used to optimize the data taking plan. It is found that by using five energy points with the total integrated luminosity of 100 pb(-1), the tau mass can be determined with a statistical error of 50 keV.
引用
收藏
页码:573 / 577
页数:5
相关论文
共 50 条
  • [31] Coriolis principle ensures high accuracy in mass flow measurement
    Mueller, R.
    Scheid, K.
    Farbe und Lack, 1997, 103 (04):
  • [32] Research on the Influence of Air Pressure to High Accuracy Mass Measurement
    Cai, Chang-Qing
    Hu, Man-Hong
    Wang, Jian
    Zhang, Yue
    Huang, Tao
    Zhong, Rui-Lin
    Jiao, Kai
    PROCEEDINGS OF THE 3RD ANNUAL INTERNATIONAL CONFERENCE ON MECHANICS AND MECHANICAL ENGINEERING (MME 2016), 2017, 105 : 467 - 471
  • [33] A High Accuracy Attitude Adjustment Method for Spacecraft Mass Property Measurement
    Yu, Rongrong
    Dong, Ligang
    Wang, Xiaoyang
    Tan, Xu
    Zhang, Yangcheng
    2018 5TH INTERNATIONAL CONFERENCE ON SYSTEMS AND INFORMATICS (ICSAI), 2018, : 45 - 49
  • [34] Development of high power waveguide valve for BEPC II-Linac
    Zhao, Feng-Li
    Liu, Jin-Tong
    Zhou, Yao-Xiang
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2006, 18 (02): : 297 - 299
  • [35] Fabrication of the high power input coupler for BEPC II superconducting cavities
    Huang Tong-Ming
    Ma Qiang
    Pan Wei-Min
    Wang Guang-Wei
    CHINESE PHYSICS C, 2008, 32 (11) : 931 - 933
  • [36] Capillary LC coupled with high-mass measurement accuracy mass spectrometry for metabolic profiling
    Ding, Jie
    Sorensen, Christina M.
    Zhang, Qibin
    Jiang, Hongliang
    Jaitly, Navdeep
    Livesay, Eric A.
    Shen, Yufeng
    Smith, Richard D.
    Metz, Thomas O.
    ANALYTICAL CHEMISTRY, 2007, 79 (16) : 6081 - 6093
  • [37] High power conditioning of the input coupler for BEPC II superconducting cavity
    Pan Wei-Min
    Huang Tong-Ming
    Ma Qiang
    Wang Guang-Wei
    Sun Yi
    Sha Peng
    Li Zhong-Quan
    Lin Hai-Ying
    Xu Bo
    CHINESE PHYSICS C, 2008, 32 (09) : 766 - 768
  • [38] Monte Carlo study of K* (892) mass splitting at BEPC II/BES III
    Sun, SS
    Shen, XY
    Zheng, ZP
    Yan, ML
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (05): : 463 - 468
  • [39] A METHOD FOR HIGH-ACCURACY MEASUREMENT OF MASS USING MODERN ELECTRONIC BALANCES
    PROKIC, D
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1982, 15 (03): : 282 - 284
  • [40] Temperature measurement with high accuracy
    Du Qingfu
    ADVANCED MEASUREMENT AND TEST, PTS 1-3, 2011, 301-303 : 1333 - 1338