A scenario for high accuracy τ mass measurement at BEPC-II

被引:9
|
作者
Achasov, M. N. [1 ]
Blinov, V. E. [1 ]
Cai Xiao [2 ]
Fu Cheng-Dong [2 ]
Harris, F. A. [3 ]
Liu, Q. [3 ]
Mo Xiao-Hu [2 ]
Muchnoi, N. Yu [1 ]
Nikolaev, I. B. [1 ]
Qin Qing [2 ]
Shamov, A. G. [1 ]
Todyshev, K. Yu [1 ]
Wang Yi-Fang [2 ]
Zhang Jian-Yong [2 ]
机构
[1] Russian Acad Sci, Budker Inst Nucl Phys, Siberian Branch, Novosibirsk 630090, Russia
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[3] Univ Hawaii, Honolulu, HI 96822 USA
基金
中国国家自然科学基金;
关键词
tau mass; scan optimization uncertainty; COLLIDER; LEPTON; SYSTEM;
D O I
10.1088/1674-1137/36/7/001
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Scenarios for the T mass measurement at the upgraded Beijing Electron-Positron Collider (BEPC-II) are studied. A nested minimization procedure is used to optimize the data taking plan. It is found that by using five energy points with the total integrated luminosity of 100 pb(-1), the tau mass can be determined with a statistical error of 50 keV.
引用
收藏
页码:573 / 577
页数:5
相关论文
共 50 条
  • [1] A scenario for high accuracy τ mass measurement at BEPC-Ⅱ
    M. N. Achasov
    V. E. Blinov
    蔡啸
    傅成栋
    F. A. Harris
    Q. Liu
    莫晓虎
    N. Yu. Muchnoi
    I. B. Nikolaev
    秦庆
    A. G. Shamov
    K. Yu. Todyshev
    王贻芳
    张建勇
    中国物理C, 2012, 36 (07) : 573 - 577
  • [2] Upgrade of beam energy measurement system at BEPC-II
    Zhang, Jian-Yong
    Cai, Xiao
    Mo, Xiao-Hu
    Guo, Di-Zhou
    Wang, Jian-Li
    Liu, Bai-Qi
    Achasov, M. N.
    Krasnov, A. A.
    Muchnoi, N. Yu.
    Pyata, E. E.
    Mamoshkina, E. V.
    Harris, F. A.
    CHINESE PHYSICS C, 2016, 40 (07)
  • [3] Energy determination at BEPC-II
    Achasov, M. N.
    Blinov, V. E.
    Bogomyagkov, A. V.
    Fu, ChengDong
    Harris, F. A.
    Kaminsky, V. V.
    Liu, Q.
    Mo, Xiaohu
    Muchnoi, N. Yu.
    Nikitin, S. A.
    Nikolaev, I. B.
    Qin, Qing
    Qu, Huamin
    Olsen, S. L.
    Pyata, E. E.
    Shamov, A. G.
    Shen, C. P.
    Varner, G. S.
    Wang, Yifang
    Xu, Jinqiang
    Zhilich, V. N.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2009, 189 : 366 - 370
  • [4] Emittance measurement with multi-wire scanners for BEPC-II linac
    Geng, H. (genghp@ihep.ac.cn), 2013, Joint Accelerator Conferences Website (JACoW)
  • [5] Status of BEPC-II and BES-III
    Olsen, Stephen L.
    INTERSECTIONS OF PARTICLE AND NUCLEAR PHYSICS, 2009, 1182 : 402 - 405
  • [6] Technique research of embedded event receiver for BEPC-II
    Zhang, Zhao
    Liu, Zhi
    Cheng, Sinong
    Lei, Ge
    Zhang, Yuliang
    Zhu, Peng
    Xu, Guanglei
    Wang, Lin
    RADIATION DETECTION TECHNOLOGY AND METHODS, 2023, 7 (01) : 124 - 133
  • [7] Technique research of embedded event receiver for BEPC-II
    Zhao Zhang
    Zhi Liu
    Sinong Cheng
    Ge Lei
    Yuliang Zhang
    Peng Zhu
    Guanglei Xu
    Lin Wang
    Radiation Detection Technology and Methods, 2023, 7 : 124 - 133
  • [8] Design and field measurement of the BEPC-II interaction region dual-aperture quadrupoles
    Yin, Z. S.
    Wu, Y. Z.
    Zhang, J. F.
    Chen, W.
    Li, Y. J.
    Li, L.
    Hou, R.
    Yin, B. G.
    Sun, X. J.
    Ren, F. L.
    Wang, F. A.
    Chen, F. S.
    Yu, C. H.
    Chen, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (03): : 323 - 328
  • [9] Charm physics with BES-III at BEPC-II
    Li, Haibo
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 162 : 312 - 319
  • [10] Probing the tau electric dipole moment at the BEPC-II collider
    Bernreuther, Werner
    Chen, Long
    Nachtmann, Otto
    PHYSICAL REVIEW D, 2021, 104 (11)