Length and refractive index measurement by Fourier transform interferometry and frequency comb spectroscopy

被引:57
|
作者
Balling, Petr [1 ]
Masika, Pavel [1 ]
Kren, Petr [1 ]
Dolezal, Miroslav [1 ]
机构
[1] Czech Metrol Inst, Prague 5, Czech Republic
关键词
interferometry; white light; gauge block; non-contact measurement; femtosecond frequency comb interferometry; length and distance measurement; refractive index; dispersion; Fourier transform spectroscopy; DISTANCE MEASUREMENT; STABILIZED LASER; AIR; MODE; CALIBRATION;
D O I
10.1088/0957-0233/23/9/094001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper we describe the progress we have made in our simultaneous length measurement and the femtosecond comb interferometric spectroscopy in a conventional arrangement with a moving mirror. Scanning and detection over an interval longer than the distance between two consecutive pulses of the frequency comb allow for a spectral resolution of the individual frequency modes of the comb. Precise knowledge of comb mode frequency leads to a precise estimation of the spectral characteristics of inspected phenomena. Using the pulse train of the frequency comb allows for measurement with highly unbalanced lengths of interferometer arms, i.e. an absolute long distance measurement. Further, we present a non-contact (double sided) method of measurement of the length/thickness of plane-parallel objects (gauge blocks, glass samples) by combining the fs comb (white light) with single frequency laser interferometry. The position of a fringe packet is evaluated by estimating the stationary phase position for any wavelength in the spectral band used. The repeatability of this position estimation is a few nanometres regardless of whether dispersion of the arms is compensated (transform limited fringe packet similar to 10 fringes FWHM) or highly different (fringe packet stretched to >200 fringes FWHM). The measurement of steel gauge block by this method was compared with the standard method, and deviation (+13 +/- 12) nm for gauge blocks (2 to 100) mm was found. The measurement of low reflecting ceramic gauges or clear glass samples was also tested. In the case of glass, it becomes possible to measure simultaneously both the thickness and the refractive index (and dispersion) of flat samples.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Fourier transform spectroscopy around 3 μm with a broad difference frequency comb
    Samuel A. Meek
    Antonin Poisson
    Guy Guelachvili
    Theodor W. Hänsch
    Nathalie Picqué
    Applied Physics B, 2014, 114 : 573 - 578
  • [22] EPIFILM THICKNESS MEASUREMENTS USING FOURIER-TRANSFORM INFRARED-SPECTROSCOPY - EFFECT OF REFRACTIVE-INDEX DISPERSION AND REFRACTIVE-INDEX MEASUREMENT
    ZHOU, ZH
    CHOI, BG
    FLIK, MI
    FAN, S
    REIF, R
    JOURNAL OF APPLIED PHYSICS, 1994, 76 (04) : 2448 - 2454
  • [23] Fourier Transform in THz Measurements of Refractive Index
    Witkowski, Jerzy S.
    Jarzab, Przemyslaw
    Nowak, Kacper
    Wilk, Rafal
    Mikulics, Martin
    Plinski, Edward F.
    2009 34TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, VOLS 1 AND 2, 2009, : 258 - +
  • [24] Multi-correlation Fourier transform spectroscopy with the resolved modes of a frequency comb laser
    Zeitouny, Mounir
    Balling, Petr
    Kren, Petr
    Masika, Pavel
    Horsten, Ronald C.
    Persijn, Stefan T.
    Urbach, H. Paul
    Bhattacharya, Nandini
    ANNALEN DER PHYSIK, 2013, 525 (06) : 437 - 442
  • [25] Accuracy of refractive index spectroscopy by broadband interferometry
    Arosa, Yago
    Damian Rodriguez-Fernandez, Carlos
    Doval, Alejandro
    Lopez Lago, Elena
    de la Fuente, Raul
    MEASUREMENT, 2022, 187
  • [26] Optical Frequency Comb Fourier Transform Spectroscopy with Resolution beyond the Path Difference Limit
    Rutkowski, Lucile
    Johansson, Alexandra C.
    Khodabakhsh, Amir
    Maslowski, Piotr
    Kowzan, Grzegorz
    Lee, Kevin F.
    Mills, Andrew A.
    Mohr, Christian
    Jiang, Jie
    Fermann, Martin E.
    Foltynowicz, Aleksandra
    2016 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2016,
  • [27] Accuracy of refractive index spectroscopy by broadband interferometry
    Arosa, Yago
    Damián Rodríguez-Fernández, Carlos
    Doval, Alejandro
    López Lago, Elena
    de la Fuente, Raúl
    Measurement: Journal of the International Measurement Confederation, 2022, 187
  • [28] Frequency Comb Fourier Transform Spectroscopy at 8 μm Using a Compact Difference Frequency Generation Source
    Germann, Matthias
    Hjalten, Adrian
    Krzempek, Karol
    Hudzikowski, Arkadiusz
    Gluszek, Aleksander
    Tomaszewska, Dorota
    Sobon, Grzegorz
    Foltynowicz, Aleksandra
    2021 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2021,
  • [29] Refractive index measurement using comparative interferometry
    Bojan, Mihaela
    Apostol, D.
    Damian, V.
    Logofatu, P. C.
    Garoi, F.
    Iordache, Iuliana
    ADVANCED TOPICS IN OPTOELECTRONICS, MICROELECTRONICS, AND NANOTECHNOLOGIES III, 2007, 6635
  • [30] FOURIER SPECTROSCOPY WITH FEMTOSECOND FREQUENCY COMB RADIATION
    Balling, P.
    Masika, P.
    Kren, P.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 109 - 110