The potential of SAPO-44 zeolite filler in fouling mitigation of polysulfone ultrafiltration membrane

被引:51
|
作者
Leo, C. P. [1 ]
Kamil, N. H. Ahmad [1 ]
Junaidi, M. U. M. [1 ]
Kamal, S. N. M. [1 ]
Ahmad, A. L. [1 ]
机构
[1] Univ Sains Malaysia, Sch Chem Engn, Sps 14300, Pulau Pinang, Malaysia
关键词
Mixed matrix membrane; Zeolite; Fouling; Humic acid; MIXED MATRIX MEMBRANE; GAS SEPARATION; INORGANIC FILLERS; UF MEMBRANES; TIO2; NANOPARTICLES; ZNO; FABRICATION; RESISTANCE; ACID;
D O I
10.1016/j.seppur.2012.10.019
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Durable polysulfone (PSI) membrane is less suitable for wastewater treatment as it is susceptible to severe fouling by the natural organic matter. In this work, SAPO-44 zeolite was blended into PSf membranes to mitigate fouling by humic acid. The casting solutions were prepared by blending 5-20 wt.% of SAPO-44 zeolite (average particle size of 138 nm) into a mixture of PSf, 1-methyl-2-pyrrolidinone and 1 wt.% of PVA at 75 degrees C with a stirring speed of 400 rpm. The weight ratio of polymer to solvent was maintained at 1:4.84. Mixed matrix membranes were then prepared using phase inversion method. SAPO-44 zeolite was weakly adhered to the macroporous layer in asymmetric membranes. Growth of the finger-like macrovoid was promoted by blending SAPO-44 zeolite into PSf/PVA membrane. Larger pore size was also induced in P-1 and P-2 samples, causing lower water contact angle on these mixed matrix membranes. Further adding of zeolite filler resulted in smaller finger-like pores as the exchange between solvent and nonsolvent had been delayed in the viscous solution. Membrane pore size and surface energy were slightly enlarged by blending 15 wt.% or 20 wt.% of zeolite. P-3 membrane with 15 wt.% of SAPO-44 exhibited the highest water flux, with nearly 164 % of increment compared to the control membrane. Fouling mitigation could be achieved without much modification of surface energy depending on the fouling mechanisms. Embedded zeolite may reduce the fouling by humic acid initiated from pore blocking. About 80% permeate flux of P-3 membrane was maintained during the filtration of humic acid solution. However, agglomerated filler in P-4 sample with 20 wt.% of SAPO-44 caused slightly lower water permeability and relative flux of fouling test compared to P-3 membrane. (C) 2012 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:84 / 91
页数:8
相关论文
共 50 条
  • [11] On the fouling mechanism of polysulfone ultrafiltration membrane in the treatment of coal gasification wastewater
    Xue Zou
    Jin Li
    Frontiers of Chemical Science and Engineering, 2016, 10 (04) : 490 - 498
  • [12] Fouling characteristics of humic substances on tight polysulfone-based ultrafiltration membrane
    Ariono, Danu
    Aryanti, Putu T. P.
    Wardani, Anita K.
    Wenten, I. G.
    MEMBRANE WATER TREATMENT, 2018, 9 (05) : 353 - 361
  • [13] Alleviating membrane fouling of modified polysulfone membrane via coagulation pretreatment/ultrafiltration hybrid process
    Yu, Chenghui
    Gao, Baoyu
    Wang, Wenyu
    Xu, Xing
    Yue, Qinyan
    CHEMOSPHERE, 2019, 235 : 58 - 69
  • [14] Robust CNT-based conductive ultrafiltration membrane with tunable surface potential for in situ fouling mitigation
    Mao, Hengyang
    Qiu, Minghui
    Zhang, Tianyu
    Chen, Xianfu
    Da, Xiaowei
    Jing, Wenheng
    Fan, Yiqun
    APPLIED SURFACE SCIENCE, 2019, 497
  • [15] E fficient heterogeneous Fenton -like catalysis of Fe -doped SAPO-44 zeolite synthesized from bauxite and rice husk
    Zhang, Qiongdan
    Wang, Qiongsheng
    Wang, Shiming
    CHEMICAL PHYSICS LETTERS, 2020, 753
  • [16] Enhanced performance of conductive polysulfone/MWCNT/PANI ultrafiltration membrane in an online fouling monitoring application
    Yuan, Xue-Shuang
    Guo, Zhi-Ying
    Geng, Hong-Zhang
    Rhen, Danielle S.
    Wang, Luda
    Yuan, Xiao-Tong
    Li, Jianxin
    JOURNAL OF MEMBRANE SCIENCE, 2019, 575 : 160 - 169
  • [17] Polyethersulfone membrane fouling mitigation during ultrafiltration of wastewaters from car washes
    Gryta, Marek
    Wozniak, Piotr
    DESALINATION, 2024, 574
  • [18] Polysulfone ultrafiltration membrane incorporated with Ag-SiO2 nanohybrid for effective fouling control
    Wu, Huiqing
    Huang, Jing
    Liu, Yuejun
    JOURNAL OF WATER AND HEALTH, 2017, 15 (03) : 341 - 352
  • [19] A novel low-fouling zeolite-polysulfone nanocomposite membrane for advanced water treatment
    Raval, Hiren D.
    Mehta, Bhargav B.
    Joshi, Rutvik N.
    DESALINATION AND WATER TREATMENT, 2017, 88 : 8 - 15
  • [20] Mitigation of irreversible membrane fouling by CNT-PVDF electrically conductive ultrafiltration membranes
    Zhang, Zhaohui
    Hu, Wenshuo
    Ma, Cong
    Zhang, Tong
    Wang, Liang
    JOURNAL OF WATER PROCESS ENGINEERING, 2024, 67