Design and Ex Vivo Evaluation of a 3D High Intensity Focused Ultrasound System for Tumor Treatment with Tissue Ablation

被引:0
|
作者
Lweesy, K. [1 ]
Fraiwan, L. [1 ]
Al-Shalabi, M. [1 ]
Mohammad, L. [1 ]
Al-Oglah, R. [1 ]
机构
[1] Jordan Univ Sci & Technol, Fac Engn, Dept Biomed Engn, Irbid 22110, Jordan
关键词
Geometrically focused transducer; high intensity focused ultrasound; lesion; sonication; treatment planning; BREAST-CANCER;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes the design, construction, and evaluation of a three dimensional (3D) ultrasound system to be used to treat different kinds of tumors using high intensity focused ultrasound (HIFU). The system consists of two major parts: an ultrasonic therapy part and a treatment planning part. The ultrasonic therapy part consists of an ultrasound bowl shaped transducer (made from Lead Zirconate Titanate (PZT) and has a resonance frequency of 0.5 MHz), a lossless electrical impedance matching circuit built to ensure maximum electrical power delivery to the transducer, a function generator, and a high power amplifier. The ultrasonic therapy part is responsible for generating a high-power focus at the location of the geometric focus of the bowl shaped ultrasound transducer. The treatment planning part consists of three stepper motors (responsible for moving the setup in the x- y- and z-directions), three high-voltage high-current darlington arrays (to supply the stepper motors with the required voltages and currents), and a C# software to perform the treatment planning. To assess the movement of the treatment planner, each of the three stepper motors was moved forward and backward from end to end. Then the treatment planner was successfully driven to cover cubes of dimensions of 1 x 1 x 1 cm(3), 2 x 2 x 2 cm(3), 4 x 4 x 4 cm(3), and 8 x 8 x 8 cm(3), with step sizes 0.5, 1, 2, and 4 mm, respectively. Ex vivo experiments using fresh bovine liver were performed and indicated the capability of the system to generate lesions both on- and off-axis. Lesions at different depths were successfully generated at the intended locations. Temperature distributions were recorded both inside and outside the lesion and indicated that the temperature reached about 60 degrees C inside the lesion and remained below 39 degrees C outside it.
引用
收藏
页码:556 / 559
页数:4
相关论文
共 50 条
  • [41] High-Intensity Focused Ultrasound for Therapeutic Tissue Ablation in Surgical Oncology
    Ward, John F.
    SURGICAL ONCOLOGY CLINICS OF NORTH AMERICA, 2011, 20 (02) : 389 - +
  • [42] TISSUE ABLATION IN BENIGN PROSTATIC HYPERPLASIA WITH HIGH-INTENSITY FOCUSED ULTRASOUND
    MADERSBACHER, S
    MARBERGER, M
    JOURNAL D UROLOGIE, 1993, 99 (06) : 349 - 349
  • [43] Extracorporeally induced ablation of renal tissue by high-intensity focused ultrasound
    Häcker, A
    Michel, MS
    Marlinghaus, E
    Köhrmann, KU
    Alken, P
    BJU INTERNATIONAL, 2006, 97 (04) : 779 - 785
  • [44] High-Intensity-Focused-Ultrasound (HIFU) induced homeostasis and tissue ablation
    Chauhan, S
    Michel, MS
    Alken, P
    Köhrmann, KU
    Haecker, A
    THERMAL TREATMENT OF TISSUE: ENERGY DELIVERY AND ASSESSMENT II, 2003, 4954 : 237 - 244
  • [45] Extracorporeal application of high-intensity focused ultrasound for prostatic tissue ablation
    Häcker, A
    Köhrmann, KU
    Back, W
    Kraut, O
    Marlinghaus, E
    Alken, P
    Michel, MS
    BJU INTERNATIONAL, 2005, 96 (01) : 71 - 76
  • [46] Tissue ablation using an acoustic waveguide for high-intensity focused ultrasound
    Sommer, FG
    Sumanaweera, TS
    Glover, G
    MEDICAL PHYSICS, 1997, 24 (04) : 537 - 538
  • [47] High intensity focused ultrasound renal tissue ablation in a laparoscopic porcine model
    Orvieto, MA
    Lyon, MB
    Mikhail, AA
    Rapp, DE
    Fedewa, R
    Seip, R
    Shalhav, AL
    JOURNAL OF UROLOGY, 2006, 175 (04): : 339 - 339
  • [48] EXTRACORPOREAL ABLATION OF LIVER-TISSUE BY HIGH-INTENSITY FOCUSED ULTRASOUND
    SIBILLE, A
    PRAT, F
    CHAPELON, JY
    ELFADIL, FA
    HENRY, L
    THEILLERE, Y
    PONCHON, T
    CATHIGNOL, D
    ONCOLOGY, 1993, 50 (05) : 375 - 379
  • [49] Quantitative Ultrasound for Monitoring High-Intensity Focused Ultrasound Treatment In Vivo
    Ghoshal, Goutam
    Kemmerer, Jeremy P.
    Karunakaran, Chandra
    Miller, Rita J.
    Oelze, Michael L.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (09) : 1234 - 1242
  • [50] High-intensity focused ultrasound shows promise for noninvasive tumor ablation
    Carol Lovegrove
    Nature Clinical Practice Oncology, 2006, 3 (1): : 8 - 9