Handheld simultaneous scanning laser ophthalmoscopy and optical coherence tomography system

被引:61
|
作者
LaRocca, Francesco [1 ]
Nankivil, Derek [1 ]
Farsiu, Sina [1 ,2 ]
Izatt, Joseph A. [1 ,2 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
[2] Duke Univ, Med Ctr, Dept Ophthalmol, Durham, NC 27710 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2013年 / 4卷 / 11期
关键词
TARGETED STIMULUS DELIVERY; ADAPTIVE OPTICS; MOTION CORRECTION; CONE PHOTORECEPTORS; IMAGE REGISTRATION; FOVEAL MORPHOLOGY; TRACKING SLO; OCT;
D O I
10.1364/BOE.4.002307
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) are widely used retinal imaging modalities that can assist in the diagnosis of retinal pathologies. The combination of SLO and OCT provides a more comprehensive imaging system and a method to register OCT images to produce motion corrected retinal volumes. While high quality, bench-top SLO-OCT systems have been discussed in the literature and are available commercially, there are currently no handheld designs. We describe the first design and fabrication of a handheld SLO/spectral domain OCT probe. SLO and OCT images were acquired simultaneously with a combined power under the ANSI limit. High signal-to-noise ratio SLO and OCT images were acquired simultaneously from a normal subject with visible motion artifacts. Fully automated motion estimation methods were performed in post-processing to correct for the inter-and intra-frame motion in SLO images and their concurrently acquired OCT volumes. The resulting set of reconstructed SLO images and the OCT volume were without visible motion artifacts. At a reduced field of view, the SLO resolved parafoveal cones without adaptive optics at a retinal eccentricity of 11 in subjects with good ocular optics. This system may be especially useful for imaging young children and subjects with less stable fixation. (C) 2013 Optical Society of America
引用
下载
收藏
页码:2307 / 2321
页数:15
相关论文
共 50 条
  • [11] Handheld probes and galvanometer scanning for optical coherence tomography
    Duma, V. -F.
    Dobre, G.
    Demian, D.
    Cernat, R.
    Sinescu, C.
    Topala, F. I.
    Negrutiu, M. L.
    Hutiu, Gh.
    Bradu, A.
    Rolland, J. P.
    Podoleanu, A. Gh.
    OPTICAL SYSTEMS DESIGN 2015: OPTICAL DESIGN AND ENGINEERING VI, 2015, 9626
  • [12] Combined Adaptive Optics - Optical Coherence Tomography and Adaptive Optics - Scanning Laser Ophthalmoscopy system for retinal imaging
    Zawadzki, Robert J.
    Jones, Steven M.
    Chen, Diana
    Choi, Stacey S.
    Evans, Julia W.
    Olivier, Scot S.
    Werner, John S.
    OPHTHALMIC TECHNOLOGIES XIX, 2009, 7163
  • [13] Optical Coherence Tomography Scanning with a Handheld Vitreoretinal Micromanipulator
    Yang, Sungwook
    Balicki, Marcin
    MacLachlan, Robert A.
    Liu, Xuan
    Kang, Jin U.
    Taylor, Russell H.
    Riviere, Cameron N.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 948 - 951
  • [14] Cirrus High-definition Optical Coherence Tomography Versus Spectral Optical Coherence Tomography/Scanning Laser Ophthalmoscopy in the Diagnosis of Glaucoma
    Koh, Kyung Min
    Jin, Sunyoung
    Hwang, Young Hoon
    CURRENT EYE RESEARCH, 2014, 39 (01) : 62 - 68
  • [15] Combined multiplanar optical coherence tomography and confocal scanning ophthalmoscopy
    Podoleanu, AG
    Dobre, GM
    Cucu, RG
    Rosen, R
    Garcia, P
    Nieto, J
    Will, D
    Gentile, R
    Muldoon, T
    Walsh, J
    Yannuzzi, LA
    Fisher, Y
    Orlock, D
    Weitz, R
    Rogers, JA
    Dunne, S
    Boxer, A
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 86 - 93
  • [16] Structure-function relationships using confocal scanning laser ophthalmoscopy, optical coherence tomography, and scanning laser polarimetry
    Bowd, Christopher
    Zangwill, Linda M.
    Medeiros, Felipe A.
    Tavares, Ivan M.
    Hoffmann, Esther M.
    Bourne, Rupert R.
    Sample, Pamela A.
    Weinreb, Robert N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (07) : 2889 - 2895
  • [17] Simultaneous multimodal ophthalmic imaging using swept-source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography
    Malone, Joseph D.
    El-Haddad, Mohamed T.
    Bozic, Ivan
    Tye, Logan A.
    Majeau, Lucas
    Godbout, Nicolas
    Rollins, Andrew M.
    Boudoux, Caroline
    Joos, Karen M.
    Patel, Shriji N.
    Tao, Yuankai K.
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (01): : 193 - 206
  • [18] Simultaneous Confocal Scanning Laser Ophthalmoscopy Combined with High-Resolution Spectral-Domain Optical Coherence Tomography: A Review
    Lima, Veronica Castro
    Rodrigues, Eduardo B.
    Nunes, Renata P.
    Sallum, Juliana F.
    Farah, Michel E.
    Meyer, Carsten H.
    JOURNAL OF OPHTHALMOLOGY, 2011, 2011
  • [19] Integrating photoacoustic ophthalmoscopy with scanning laser ophthalmoscopy, optical coherence tomography, and fluorescein angiography for a multimodal retinal imaging platform
    Song, Wei
    Wei, Qing
    Liu, Tan
    Kuai, David
    Burke, Janice M.
    Jiao, Shuliang
    Zhang, Hao F.
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (06)
  • [20] Scanning laser ophthalmoscopy-optical coherence tomography (OCT/SLO) evaluation of choroidal nevi
    Page, JP
    Garcia, PMT
    Schneider, S
    Rosen, RB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46