Removal of diclofenac by conventional drinking water treatment processes and granular activated carbon filtration

被引:77
|
作者
Rigobello, Eliane Sloboda [1 ]
Dantas, Angela Di Bernardo [2 ]
Di Bernardo, Luiz [3 ]
Vieira, Eny Maria [1 ]
机构
[1] Univ Sao Paulo, Inst Chem Sao Carlos, Dept Chem & Mol Phys, BR-13566570 Sao Carlos, SP, Brazil
[2] Univ Assoc Sch Ribeirao Preto UNAERP, BR-14906900 Ribeirao Preto, Brazil
[3] Univ Sao Paulo, Sao Carlos Sch Engn, Dept Hydraul & Sanitat, BR-13566570 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Diclofenac; Drinking water treatment; Chlorine; Chlorine dioxide; Granular activated carbon; Byproducts; ADVANCED OXIDATION PROCESSES; AQUATIC HUMIC SUBSTANCES; ENDOCRINE DISRUPTORS; WASTE-WATER; ORGANIC CONTAMINANTS; CHLORINE DIOXIDE; TREATMENT PLANTS; PHARMACEUTICALS; DEGRADATION; FATE;
D O I
10.1016/j.chemosphere.2013.03.010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study was carried out to evaluate the efficiency of conventional drinking water treatment processes with and without pre-oxidation with chlorine and chlorine dioxide and the use of granular activated carbon (GAC) filtration for the removal of diclofenac (DCF). Water treatment was performed using the Jar test with filters on a lab scale, employing nonchlorinated artesian well water prepared with aquatic humic substances to yield 20 HU true color, kaolin turbidity of 70 NTU and 1 mg L-1 DCF. For the quantification of DCF in water samples, solid phase extraction and HPLC-DAD methods were developed and validated. There was no removal of DCF in coagulation with aluminum sulfate (3.47 mg Al L-1 and pH = 6.5), flocculation, sedimentation and sand filtration. In the treatment with pre-oxidation and disinfection, DCF was partially removed, but the concentration of dissolved organic carbon (DOC) was unchanged and byproducts of DCF were observed. Chlorine dioxide was more effective than chorine in oxidizing DCF. In conclusion, the identification of DCF and DOC in finished water indicated the incomplete elimination of DCF through conventional treatments. Nevertheless, conventional drinking water treatment followed by GAC filtration was effective in removing DCF ( >= 99.7%). In the oxidation with chlorine, three byproducts were tentatively identified, corresponding to a hydroxylation, aromatic substitution of one hydrogen by chlorine and a decarboxylation/hydroxylation. Oxidation with chlorine dioxide resulted in only one byproduct (hydroxylation). (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:184 / 191
页数:8
相关论文
共 50 条
  • [41] A comparison of removal efficiencies of conventional drinking water treatment and advanced treatment equipped with ozone-biological activated carbon process
    Shen, Hong
    Fan, Hongliang
    Wu, Nanxiang
    Hu, Jun
    ENVIRONMENTAL TECHNOLOGY, 2021, 42 (26) : 4079 - 4089
  • [42] Removal of the waterborne parasite Cryptosporidium parvum from drinking water using granular activated carbon
    Couso-Perez, Seila
    Abeledo-Lameiro, Maria Jesus
    Vidal-Varela, Ana Isabel
    Gomez-Couso, Hipolito
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2023, 11 (06):
  • [43] REMOVAL OF TRACE MERCURY(II) FROM DRINKING-WATER - SORPTION BY GRANULAR ACTIVATED CARBON
    MA, X
    SUBRAMANIAN, KS
    CHAKRABARTI, CL
    GUO, R
    CHENG, J
    LU, Y
    PICKERING, WF
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1992, A27 (06): : 1389 - 1404
  • [44] Removal of the Cyanotoxin Microcystin-LR from Drinking Water Using Granular Activated Carbon
    Villars, Kathryn
    Huang, Yuzhou
    Lenhart, John J.
    ENVIRONMENTAL ENGINEERING SCIENCE, 2020, 37 (09) : 585 - 595
  • [45] Preparation of iron-impregnated granular activated carbon for arsenic removal from drinking water
    Chang, Qigang
    Lin, Wei
    Ying, Wei-chi
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 184 (1-3) : 515 - 522
  • [46] Dispersion of C60 in natural water and removal by conventional drinking water treatment processes
    Hyung, Hoon
    Kim, Jae-Hong
    WATER RESEARCH, 2009, 43 (09) : 2463 - 2470
  • [47] Cost-effective water treatment of polluted surface water by using direct filtration and granular activated carbon filtration
    Cromphout, J
    Rogge, W
    INNOVATIONS IN CONVENTIONAL AND ADVANCED WATER TREATMENT PROCESSES, 2002, 2 (01): : 233 - 240
  • [48] A pilot plant study of the processes of filtration and adsorption of drinking water through granular activated carbons: a comparative study
    Garcia Prieto, Juan Carlos
    Perez Galende, Patricia
    Cachaza Silverio, Juan Manuel
    Garcia Roig, Manuel
    WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2013, 13 (01): : 74 - 88
  • [49] Efficient Mn(II) removal by biological granular activated carbon filtration
    Chen, Qi
    Li, Guiwei
    Lu, Zhili
    Su, Yuliang
    Wu, Bin
    Shi, Baoyou
    JOURNAL OF HAZARDOUS MATERIALS, 2023, 458
  • [50] EFFECTIVENESS OF GRANULAR ACTIVATED CARBON TREATMENT FOR REMOVING MUTAGENS FROM DRINKING-WATER
    MEIER, JR
    MONARCA, S
    BULL, RJ
    KOPFLER, FC
    ENVIRONMENTAL MUTAGENESIS, 1982, 4 (03): : 381 - 381