High-throughput and simultaneous quantitative analysis of homocysteine-methionine cycle metabolites and co-factors in blood plasma and cerebrospinal fluid by isotope dilution LC-MS/MS

被引:67
|
作者
Guiraud, Seu Ping [1 ]
Montoliu, Ivan [1 ]
Da Silva, Laeticia [1 ]
Dayon, Loic [1 ]
Galindo, Antonio Nunez [1 ]
Corthesy, John [1 ]
Kussmann, Martin [1 ]
Martin, Francois-Pierre [1 ]
机构
[1] Nestle Inst Hlth Sci SA, Campus EPFL,Innovat Pk, CH-1015 Lausanne, Switzerland
关键词
Methionine pathway; One-carbon metabolism; LC-MS/MS; High throughput; Plasma; Cerebrospinal fluid; ONE-CARBON METABOLISM; PERFORMANCE LIQUID-CHROMATOGRAPHY; S-ADENOSYLMETHIONINE; ALZHEIMERS-DISEASE; MASS-SPECTROMETRY; AMINO-ACIDS; FOLATE; CYSTEINE; CHOLINE; URINE;
D O I
10.1007/s00216-016-0003-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The methionine cycle is a key pathway contributing to the regulation of human health, with well-established involvement in cardiovascular diseases and cognitive function. Changes in one-carbon cycle metabolites have also been associated with mild cognitive decline, vascular dementia, and Alzheimer's disease. Today, there is no single analytical method to monitor both metabolites and co-factors of the methionine cycle. To address this limitation, we here report for the first time a new method for the simultaneous quantitation of 17 metabolites in the methionine cycle, which are homocysteic acid, taurine, serine, cysteine, glycine, homocysteine, riboflavin, methionine, pyridoxine, cystathionine, pyridoxamine, S-adenosylhomocysteine, S-adenosylmethionine, betaine, choline, dimethylglycine, and 5-methyltetrahydrofolic acid. This multianalyte method, developed using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), provides a highly accurate and precise quantitation of these 17 metabolites for both plasma and cerebrospinal fluid metabolite monitoring. The method requires a simple sample preparation, which, combined with a short chromatographic run time, ensures a high sample throughput. This analytical strategy will thus provide a novel metabolomics approach to be employed in large-scale observational and intervention studies. We expect such a robust method to be particularly relevant for broad and deep molecular phenotyping of individuals in relation to their nutritional requirements, health monitoring, and disease risk management.
引用
收藏
页码:295 / 305
页数:11
相关论文
共 42 条
  • [21] Simultaneous analysis of sildenafil, vardenafil, tadalafil, and their desalkyl metabolites in human whole blood and urine by isotope dilution LC–MS–MS
    Koutaro Hasegawa
    Osamu Suzuki
    Kunio Gonmori
    Itaru Yamagishi
    Hideki Nozawa
    Kanako Watanabe
    [J]. Forensic Toxicology, 2012, 30 : 25 - 32
  • [22] Development and validation of a sensitive and high-throughput LC-MS/MS method for the simultaneous determination of esomeprazole and naproxen in human plasma
    Gopinath, Shanmugam
    Kumar, Ramadass Satiesh
    Shankar, Madhira Bhawani
    Danabal, Palanisamy
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (07) : 894 - 899
  • [23] Supported liquid extraction in combination with LC-MS/MS for high-throughput quantitative analysis of hydrocortisone in mouse serum
    Wu, Shari
    Li, Wenkui
    Mujamdar, Tapan
    Smith, Tom
    Bryant, Matthew
    Tse, Francis L. S.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (06) : 632 - 638
  • [24] High-throughput assay for simultaneous quantification of the plasma concentrations of morphine, fentanyl, midazolam and their major metabolites using automated SPE coupled to LC-MS/MS
    Ghassabian, Sussan
    Moosavi, Seyed Mojtaba
    Valero, Yarmarly Guerra
    Shekar, Kiran
    Fraser, John F.
    Smith, Maree T.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 903 : 126 - 133
  • [25] Simultaneous analysis of sildenafil, vardenafil, tadalafil, and their desalkyl metabolites in human whole blood and urine by isotope dilution LC-MS-MS
    Hasegawa, Koutaro
    Suzuki, Osamu
    Gonmori, Kunio
    Yamagishi, Itaru
    Nozawa, Hideki
    Watanabe, Kanako
    [J]. FORENSIC TOXICOLOGY, 2012, 30 (01) : 25 - 32
  • [26] An LC-MS/MS method for rapid and sensitive high-throughput simultaneous determination of various protein kinase inhibitors in human plasma
    Abdelhameed, Ali S.
    Attwa, Mohamed W.
    Kadi, Adnan A.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (02)
  • [27] Quantitative Investigation of Trigonelline, Nicotinic Acid, and Nicotinamide in Foods, Urine, and Plasma by Means of LC-MS/MS and Stable Isotope Dilution Analysis
    Lang, Roman
    Yagar, Erkan Firat
    Eggers, Rudolf
    Hofmann, Thomas
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (23) : 11114 - 11121
  • [28] The development and validation of a high-throughput LC-MS/MS method for the analysis of endogenous β-hydroxy-β-methylbutyrate in human plasma
    Ramachandran, Subramanian
    Ehling, Stefan
    Shreeram, Sathyavageeswaran
    Reddy, Todime M.
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2017, 31 (07)
  • [29] Exploring electromembrane extraction coupled to fast LC-MS/MS as a high-throughput platform for determination of 12 polar endogenous metabolites in human plasma
    Hay, Anne Oldeide
    Hansen, Frederik André
    [J]. Journal of Chromatography A, 2024, 1737
  • [30] High-throughput LC-MS/MS Method for Simultaneous Determination of Pantopra-zole and Atorvastatin in Rat Plasma: Application to a Pharmacokinetic Interaction Study
    Le, Jian
    Liao, Yuehua
    Li, Shengni
    Chen, Xiujuan
    Hong, Zhanying
    [J]. CURRENT DRUG METABOLISM, 2021, 22 (06) : 481 - 490