Evaluation of a point-of-care immunoassay test kit 'StrongStep' for cryptococcal antigen detection

被引:24
|
作者
Mpoza, Edward [1 ]
Mukaremera, Liliane [1 ,2 ]
Kundura, Didas Atwebembere [3 ]
Akampurira, Andrew [4 ]
Luggya, Tonny [4 ]
Tadeo, Kiiza Kandole [1 ]
Pastick, Katelyn A. [2 ]
Bridge, Sarah C. [2 ]
Tugume, Lillian [1 ]
Kiggundu, Reuben [1 ]
Musubire, Abdu K. [1 ]
Williams, Darlisha A. [1 ,2 ]
Muzoora, Conrad [5 ]
Nalintya, Elizabeth [1 ]
Rajasingham, Radha [2 ]
Rhein, Joshua [1 ,2 ]
Boulware, David R. [2 ]
Meya, David B. [1 ,2 ]
Abassi, Mahsa [1 ,2 ]
机构
[1] Infect Dis Inst, Kampala, Uganda
[2] Univ Minnesota, Minneapolis, MN USA
[3] Makerere Univ Johns Hopkins Univ Res Collaborat, Kampala, Uganda
[4] Makerere Univ, Dept Microbiol, Kampala, Uganda
[5] Mbarara Univ Sci & Technol, Mbarara, Uganda
来源
PLOS ONE | 2018年 / 13卷 / 01期
基金
英国医学研究理事会;
关键词
ANTIRETROVIRAL THERAPY; GLOBAL BURDEN; LATERAL FLOW; MENINGITIS; DIAGNOSIS; SERUM;
D O I
10.1371/journal.pone.0190652
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background HIV-associated cryptococcal meningitis is the leading cause of adult meningitis in Sub-Saharan Africa, accounting for 15%-20% of AIDS-attributable mortality. The development of point-of-care assays has greatly improved the screening and diagnosis of cryptococcal disease. We evaluated a point-of-care immunoassay, StrongStep (Liming Bio, Nanjing, Jiangsu, China) lateral flow assay (LFA), for cryptococcal antigen (CrAg) detection in cerebrospinal fluid (CSF) and plasma. Methods We retrospectively tested 143 CSF and 77 plasma samples collected from HIV-seropositive individuals with suspected meningitis from 2012-2016 in Uganda. We prospectively tested 90 plasma samples collected from HIV-seropositive individuals with CD4 cell count <100 cells/mu L from 2016-2017 as part of a cryptococcal antigenemia screening program. The StrongStep CrAg was tested against a composite reference standard of positive Immy CrAg LFA (Immy, Norman, OK, USA) or CSF culture with statistical comparison by McNemar's test. Results StrongStep CrAg had a 98% (54/55) sensitivity and 90% (101/112) specificity in plasma (P = 0.009, versus reference standard). In CSF, the StrongStep CrAg had 100% (101/101) sensitivity and 98% (41/42) specificity (P = 0.99). Adjusting for the cryptococcal antigenemia prevalence of 9% in Uganda and average cryptococcal meningitis prevalence of 37% in Sub-Saharan Africa, the positive predictive value of the StrongStep CrAg was 50% in plasma and 96% in CSF. Conclusions We found the StrongStep CrAg LFA to be a sensitive assay, which unfortunately lacked specificity in plasma. In lower prevalence settings, a majority of positive results from blood would be expected to be false positives.
引用
下载
收藏
页数:8
相关论文
共 50 条
  • [21] Evaluation of a point-of-care rapid diagnostic test kit (SICKLECHECK) for screening of sickle cell diseases
    Purohit, Prasanta
    Parida, Chinmayee
    Martha, Tapan Kumar
    Bholo, Snehal
    Naik, Aparupa
    Behera, Samira Kumar
    PLOS ONE, 2024, 19 (08):
  • [22] Performance of a Point-of-Care Test for the Rapid Detection of SARS-CoV-2 Antigen
    Stroemer, Annabelle
    Rose, Ruben
    Schaefer, Miriam
    Schoen, Frieda
    Vollersen, Anna
    Lorentz, Thomas
    Fickenscher, Helmut
    Krumbholz, Andi
    MICROORGANISMS, 2021, 9 (01) : 1 - 11
  • [23] Gonococcal antigen detection by Immunochromatographic assay: A reliable and point-of-care diagnostic test for gonorrhoea
    Alam, Shah
    Salam, Abdus
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2012, 28 (01) : 130 - 134
  • [24] Evaluation of a Point-of-Care Test for Bilirubin in Malawi
    Shapiro, Alyssa
    Anderson, Jessica
    Mtenthaonga, Prince
    Kumwenda, Watson
    Bond, Meaghan
    Schwarz, Richard
    Carns, Jennifer
    Johnston, Ryan
    Dube, Queen
    Chiume, Msandeni
    Richards-Kortum, Rebecca
    PEDIATRICS, 2022, 150 (02)
  • [25] Evaluation of the point-of-care Afinion™ CRP test
    Van Aelst, S.
    Peeters, L.
    Cardinaels, H.
    Verjans, M-P.
    Raes, M.
    Mewis, A.
    ACTA CLINICA BELGICA, 2015, 70 : S9 - S10
  • [26] Development and evaluation of a rapid point-of-care test for detecting the hepatitis E virus antigen
    Ying, Dong
    Hong, Congming
    Wen, Guiping
    Tang, Zimin
    Wang, Siling
    Zhang, Xu
    Liu, Chang
    Ge, Shengxiang
    Zheng, Zizheng
    Xia, Ningshao
    CLINICAL BIOCHEMISTRY, 2018, 55 : 89 - 92
  • [27] Use of the Correlation Coefficient to Compare a Point-of-Care Antigen Test Against a Quantitative Sandwich Enzyme-Linked Immunosorbent Assay for the Detection of Cryptococcal Meningitis
    Lee, Sue J.
    Newton, Paul N.
    CLINICAL INFECTIOUS DISEASES, 2012, 55 (12) : 1744 - 1745
  • [28] Apropos 'A simple and inexpensive point-of-care test for hepatitis B surface antigen detection: serological and molecular evaluation' - a suggestion
    Arya, S. C.
    Agarwal, N.
    JOURNAL OF VIRAL HEPATITIS, 2014, 21 (10) : E143 - E143
  • [29] Evaluation of a rapid antigen detection point-of-care test for respiratory syncytial virus and influenza in a pediatric hospitalized population in the Netherlands
    Bruning, Andrea H. L.
    van Dijk, Karin
    van Eijk, Hetty W. M.
    Koen, Gerrit
    van Woensel, Job B. M.
    Kruisinga, Frea H.
    Pajkrt, Dasja
    Wolthers, Katja C.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2014, 80 (04) : 292 - 293
  • [30] Development and evaluation of an immunochromatography-based point-of-care test kit for a rapid diagnosis of human cysticercosis
    Sadaow, Lakkhana
    Boonroumkaew, Patcharaporn
    Rodpai, Rutchanee
    Janwan, Penchom
    Sanpool, Oranuch
    Thanchomnang, Tongjit
    Morishima, Yasuyuki
    Sato, Marcello Otake
    Sako, Yasuhito
    Kobayashi, Kaoru
    Iwai, Misako
    Maleewong, Wanchai
    Yamasaki, Hiroshi
    Intapan, Pewpan M.
    FOOD AND WATERBORNE PARASITOLOGY, 2023, 33