Three-dimensional magnetization-prepared time-of-flight MR angiography of the carotid and vertebral arteries

被引:11
|
作者
Wilman, AH [1 ]
Huston, J [1 ]
Riederer, SJ [1 ]
机构
[1] MAYO CLIN & MAYO FDN, MR RES LAB, ROCHESTER, MN 55905 USA
关键词
carotid artery; MR angiography; magnetization-prepared; centric view order;
D O I
10.1002/mrm.1910370219
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Three-dimensional magnetization-prepared (MP) MR angiography (MRA) was applied to the carotid and vertebral arteries by using ECG triggering, a slab selective RF inversion pulse, centric phase encoding and acquisition during diastole. Both theoretically and experimentally, the MP MRA sequence was shown to perform well in cases where there was substantial blood replenishment during the inversion time Tl (>330 ms). In comparison with standard, ungated, steady-state 3D time-of-flight MRA in 13 consecutive volunteers, the MP MRA images demonstrated better background suppression with less artifact and generally had more uniform vessel depiction. The MP MRA sequence was generally superior for portraying vessels exhibiting high pulsatility such as the carotid siphon. However, in distal vessels with slow flow and incomplete blood replenishment, the MP MRA technique was inferior due to increased loss of vessel signal. The reasons for this increased signal loss are identified and improvements to the MP MRA sequence are suggested.
引用
收藏
页码:252 / 259
页数:8
相关论文
共 50 条
  • [41] Circle of Willis: Morphologic variation on three-dimensional time-of-flight MR angiograms
    Krabbe-Hartkamp, MJ
    van der Grond, J
    de Leeuw, FE
    de Groot, JC
    Algra, A
    Hillen, B
    Breteler, MMB
    Mali, WPTM
    RADIOLOGY, 1998, 207 (01) : 103 - 111
  • [42] Arterial-phase three-dimensional contrast-enhanced MR angiography of the carotid arteries
    Levy, RA
    Prince, MR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) : 211 - 215
  • [43] Three-dimensional contrast-enhanced MR angiography of the extracranial carotid arteries: Two techniques
    Levy, RA
    Maki, JH
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (04) : 688 - 690
  • [44] Magnetization transfer on in vitro circulating blood: Implications for time-of-flight MR angiography
    Dousset, V
    Degreze, P
    Mieze, S
    Sesay, M
    BasseCathalinat, B
    Caille, JM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06): : 786 - 788
  • [45] Three-Dimensional Mapping with Time-of-Flight Cameras
    May, Stefan
    Droeschel, David
    Holz, Dirk
    Fuchs, Stefan
    Malis, Ezio
    Nuechter, Andreas
    Hertzberg, Joachim
    JOURNAL OF FIELD ROBOTICS, 2009, 26 (11-12) : 934 - 965
  • [46] CAROTID-ARTERY STENOSIS - CLINICAL EFFICACY OF 2-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    HEISERMAN, JE
    DRAYER, BP
    FRAM, EK
    KELLER, PJ
    BIRD, CR
    HODAK, JA
    FLOM, RA
    RADIOLOGY, 1992, 182 (03) : 761 - 768
  • [47] Preliminary evaluation of volume-rendered three-dimensional display of time-of-flight MR angiography in the diagnosis of intracranial aneurysms
    K. Tsuchiya
    S. Katase
    A. Yoshino
    J. Hachiya
    K. Yodo
    Neuroradiology, 2001, 43 : 633 - 636
  • [48] Preliminary evaluation of volume-rendered three-dimensional display of time-of-flight MR angiography in the diagnosis of intracranial aneurysms
    Tsuchiya, K
    Katase, S
    Yoshino, A
    Hachiya, J
    Yodo, K
    NEURORADIOLOGY, 2001, 43 (08) : 633 - 636
  • [49] Gadolinium-enhanced breathhold three-dimensional time-of-flight renal MR angiography in the evaluation of potential renal donors
    Nelson, HA
    Gilfeather, M
    Holman, JM
    Nelson, EW
    Yoon, HC
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (02) : 175 - 181
  • [50] Influence of imaging parameters, flow velocity, and pulsatile flow on three-dimensional time-of-flight MR angiography: experimental studies
    Kodama, T
    Watanabe, K
    EUROPEAN JOURNAL OF RADIOLOGY, 1997, 26 (01) : 83 - 91