A BGO scintillating bolometer for γ and α spectroscopy

被引:11
|
作者
Cardani, L. [1 ,2 ]
Di Domizio, S. [3 ]
Gironi, L. [4 ,5 ]
机构
[1] Univ Roma La Sapienza, Dipartimento Fis, I-00185 Rome, Italy
[2] Sez INFN Roma, I-00185 Rome, Italy
[3] Sez INFN Genova, I-16146 Genoa, Italy
[4] Univ Milano Bicocca, Dipartimento Fis, I-20126 Milan, Italy
[5] Sez INFN Milano Bicocca, I-20126 Milan, Italy
来源
关键词
Particle identification methods; Solid state detectors; Cryogenic detectors; Calorimeters; DOUBLE-BETA-DECAY; DETECTORS; NEUTRON; BISMUTH;
D O I
10.1088/1748-0221/7/10/P10022
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A 891 g BGO (Bi4Ge3O12) scintillating bolometer has been tested at 10 mK in the underground Laboratori Nazionali del Gran Sasso (Italy). The discrimination capability, the radio-purity of the compound and the main features of the crystal have been studied in order to demonstrate the excellent performances obtained by operating a scintillating bolometer in the field of gamma and alpha spectroscopy. The sensitivity of this detector in the study of extremely low surface contaminations has been investigated.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Deposition of scintillating layers of bismuth germanate (BGO) films for x-ray detector applications
    Duan, M
    Frojdh, C
    Thungstrom, G
    Wang, LW
    Linnros, J
    Petersson, CS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 525 - 527
  • [32] A CUPID Li2100MoO4 scintillating bolometer tested in the CROSS underground facility
    Armatol, A.
    Armengaud, E.
    Armstrong, W.
    Augier, C.
    Avignone, F. T., III
    Azzolini, O.
    Bandac, I. C.
    Barabash, A. S.
    Bari, G.
    Barresi, A.
    Baudin, D.
    Bellini, F.
    Benato, G.
    Beretta, M.
    Berge, L.
    Bourgeois, Ch
    Biassoni, M.
    Billard, J.
    Boldrini, V
    Branca, A.
    Brofferio, C.
    Bucci, C.
    Calvo-Mozota, J. M.
    Camilleri, J.
    Candela, A.
    Capelli, S.
    Cappelli, L.
    Cardani, L.
    Carniti, P.
    Casali, N.
    Cazes, A.
    Celi, E.
    Chang, C.
    Chapellier, M.
    Charrier, A.
    Chiesa, D.
    Clemenza, M.
    Colantoni, I
    Collamati, F.
    Copello, S.
    Cremonesi, O.
    Creswick, R. J.
    Cruciani, A.
    D'Addabbo, A.
    D'Imperio, G.
    Dafinei, I
    Danevich, F. A.
    de Combarieu, M.
    De Deo, M.
    De Jesus, M.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (02)
  • [33] Study of a Large CaF2(Eu) Scintillating Bolometer for Neutrinoless Double Beta Decay
    Li, X.
    Kwon, D. H.
    Tetsuno, K.
    Kim, I.
    Kim, H. L.
    Lee, H. J.
    Yoshida, S.
    Kim, Y. H.
    Lee, M. K.
    Umehara, S.
    Kishimoto, T.
    16TH INTERNATIONAL CONFERENCE ON TOPICS IN ASTROPARTICLE AND UNDERGROUND PHYSICS (TAUP 2019), 2020, 1468
  • [34] SUPERCONDUCTING GRANULAR NBN BOLOMETER FOR ULTRAFAST SPECTROSCOPY
    WOLF, SA
    STROM, U
    CULBERTSON, JC
    PAGET, D
    IEEE TRANSACTIONS ON MAGNETICS, 1985, 21 (02) : 920 - 923
  • [35] Terahertz spectroscopy with a Josephson oscillator and a SINIS bolometer
    M. Tarasov
    L. Kuz’min
    E. Stepantsov
    I. Agulo
    A. Kalabukhov
    M. Fominskii
    Z. Ivanov
    T. Claeson
    Journal of Experimental and Theoretical Physics Letters, 2004, 79 : 298 - 303
  • [36] Terahertz spectroscopy with a Josephson oscillator and a SINIS bolometer
    Tarasov, M
    Kuz'min, L
    Stepantsov, E
    Agulo, I
    Kalabukhov, A
    Fominskii, M
    Ivanov, Z
    Claeson, T
    JETP LETTERS, 2004, 79 (06) : 298 - 303
  • [37] Scintillating and particle discrimination properties of selected crystals for low-temperature bolometers: from LiF to BGO
    Coron, N
    Dambier, G
    Leblanc, E
    Leblanc, J
    de Marcillac, P
    Moalic, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 520 (1-3): : 159 - 162
  • [38] Bismuth germanate (BGO) array for spectroscopy of gamma pulse
    Goldin, FJ
    McCrea, EJ
    Stewart, RE
    GAMMA-RAY AND COSMIC-RAY DETECTORS, TECHNIQUES, AND MISSIONS, 1996, 2806 : 536 - 544
  • [39] Growth and characterization of a Li2Mg2(MoO4)3 scintillating bolometer
    Danevich, F. A.
    Degoda, V. Ya.
    Dulger, L. L.
    Dumoulin, L.
    Giuliani, A.
    de Marcillac, P.
    Marnieros, S.
    Nones, C.
    Novati, V.
    Olivieri, E.
    Pavlyuk, A. A.
    Poda, D. V.
    Trifonov, V. A.
    Yushina, I. V.
    Zolotarova, A. S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 889 : 89 - 96
  • [40] Performances of a large mass ZnMoO4 scintillating bolometer for a next generation 0νDBD experiment
    J. W. Beeman
    F. Bellini
    C. Brofferio
    L. Cardani
    N. Casali
    O. Cremonesi
    I. Dafinei
    S. Di Domizio
    F. Ferroni
    E. Gorello
    E. N. Galashov
    L. Gironi
    S. S. Nagorny
    F. Orio
    M. Pavan
    L. Pattavina
    G. Pessina
    G. Piperno
    S. Pirro
    E. Previtali
    C. Rusconi
    V. N. Shlegel
    C. Tomei
    M. Vignati
    The European Physical Journal C, 2012, 72