Direct electron transfer reaction of laccase on a glassy carbon electrode modified with 1-aminopyrene functionalized reduced graphene oxide

被引:22
|
作者
Zhou, Xiao-hong [1 ]
Huang, Xin-rui [1 ]
Liu, Lan-hua [1 ]
Bai, Xue [1 ]
Shi, Han-chang [1 ]
机构
[1] Tsinghua Univ, Sch Environm, State Key Joint Lab Environm Simulat & Pollut Con, Beijing 100084, Peoples R China
关键词
DIRECT ELECTROCHEMISTRY; HORSERADISH-PEROXIDASE; BIOSENSOR; GOLD; REDUCTION; NANOTUBES; PROTEINS; PHENOLS; SURFACE;
D O I
10.1039/c3ra42312c
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A biosensor was developed based on the covalent immobilization of laccase (Lac) on 1-aminopyrene (1-AP)-functionalized reduced graphene oxide (rGO)-modified glassy carbon electrode (GCE) by encapsulation with chitosan. X-ray photoelectron spectroscopy and cyclic voltammetry were used to optimize the mass ratio between 1-AP and rGO (rAP/rGO) to be 1/8. Direct electron transfer behavior of Lac immobilized on 1-AP-functionalized rGO (AP-rGO) was investigated by cyclic voltammogram. Results indicate that the AP-rGO is a friendly platform for the immobilization of enzyme, which facilitates the electron exchange between Lac and the modified electrode surface. On AP-rGO/GCE, Lac displayed rapid electron transfer with one participating proton. Furthermore, it was also confirmed that Lac immobilized on the modified electrode exhibited the electrocatalytic response to an established unspecific Lac substrate, 2,2'-azinobis (3-ethylbenzothiazoline-6-sulfonate)diammonium salt (ABTS). Without the aid of an electron mediator between Lac and modified electrode, the enzyme-based biosensor shows good reproducibility and high sensitivity to ABTS with a detection limit of 0.1 mu M (S/N = 3). Within the concentration of 2-1000 mu M, a linear relationship was achieved between the current intensity of the electro-catalytic oxidation of ABTS and the concentration of ABTS. The proposed biosensor achieved 95% of steady-state reduction currents within 5 s.
引用
收藏
页码:18036 / 18043
页数:8
相关论文
共 50 条
  • [31] Glassy carbon electrodes modified with gelatin functionalized reduced graphene oxide nanosheet for determination of gallic acid
    FERESHTEH CHEKIN
    SAMIRA BAGHERI
    SHARIFAH BEE ABD HAMID
    Bulletin of Materials Science, 2015, 38 : 1711 - 1716
  • [32] Fenitrothion sensing with reduced graphene oxide decorated fumed silica nanocomposite modified glassy carbon electrode
    Ozcan, Ali
    Topcuogullari, Duygu
    Ozcan, Ayca Atilir
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 284 : 179 - 185
  • [33] Electro-reduced graphene oxide film modified glassy carbon electrode as an electrochemical sensor for sibutramine
    Teradal, Nagappa L.
    Narayan, Prashanth S.
    Jaladappagari, Seetharamappa
    ANALYTICAL METHODS, 2013, 5 (24) : 7090 - 7095
  • [34] Simultaneous Determination of p-Benzoquinone and Resorcinol at Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Oliveira, Eleilde de S.
    Marques, Aldalea L. B.
    Alves, Ismael Carlos B.
    Marques, Edmar P.
    dos Santos, Jose Ribamar N.
    Sawczuk, Raquel B. dos S.
    de Azevedo, Lorena C. Martiniano
    Sousa, Janyeid Karla Castro
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2024, 16 (10): : 910 - 927
  • [35] Electrochemical Behavior and Determination of Matrine by the Reduced Graphene Oxide-Nafion Modified Glassy Carbon Electrode
    Zhang, Hongjiao
    Xiong, Huabin
    Gao, Yuntao
    Wang, Zhengwei
    Li, Xiaofen
    Ma, Xiaoyan
    Yang, Hongqiao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (08): : 6348 - 6358
  • [36] Sensing hydrogen peroxide with a glassy carbon electrode modified with silver nanoparticles, AlOOH and reduced graphene oxide
    Ziyin Yang
    Chengcheng Qi
    Xiaohui Zheng
    Jianbin Zheng
    Microchimica Acta, 2016, 183 : 1131 - 1136
  • [37] Sensing hydrogen peroxide with a glassy carbon electrode modified with silver nanoparticles, AlOOH and reduced graphene oxide
    Yang, Ziyin
    Qi, Chengcheng
    Zheng, Xiaohui
    Zheng, Jianbin
    MICROCHIMICA ACTA, 2016, 183 (03) : 1131 - 1136
  • [38] Dopamine sensor based on a glassy carbon electrode modified with a reduced graphene oxide and palladium nanoparticles composite
    Selvakumar Palanisamy
    Shuhao Ku
    Shen-Ming Chen
    Microchimica Acta, 2013, 180 : 1037 - 1042
  • [39] Dopamine sensor based on a glassy carbon electrode modified with a reduced graphene oxide and palladium nanoparticles composite
    Palanisamy, Selvakumar
    Ku, Shuhao
    Chen, Shen-Ming
    MICROCHIMICA ACTA, 2013, 180 (11-12) : 1037 - 1042
  • [40] Electrochemical studies of NADH oxidation on chemically reduced graphene oxide nanosheets modified glassy carbon electrode
    Immanuel, Susan
    Sivasubramanian, R.
    MATERIALS CHEMISTRY AND PHYSICS, 2020, 249