Biometry of the fetal corpus callosum by three-dimensional ultrasound

被引:65
|
作者
Pashaj, S. [1 ,2 ]
Merz, E. [2 ]
Wellek, S. [3 ]
机构
[1] Matern Hosp, Tirana 1000, Albania
[2] Krankenhaus NW Frankfurt, Ctr Prenatal Diag & Therapy, Frankfurt, Germany
[3] Johannes Gutenberg Univ Mainz, Dept Med Biostat Epidemiol & Informat, D-55122 Mainz, Germany
关键词
biometric measurements; body; corpus callosal length; fetus; genu; neurosonography; rostrum; splenium; BRAIN; DIAGNOSIS; 2ND; 3D;
D O I
10.1002/uog.12501
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
ObjectivesTo construct reference ranges of quantitative characteristics of the fetal corpus callosum. MethodsWomen referred to a tertiary center for sonographic examination were recruited to undergo a detailed fetal scan from 17 to 41weeks of gestation. Three-dimensional (3D) sonographic volumes of normal fetal brains were acquired and analyzed offline. We obtained three different measurements of the corpus callosal length, as well as the height (/thickness) of its segments, namely the rostrum, genu, body and splenium. ResultsInitially we recruited 604 pregnant women, of whom 138 were excluded because of various disorders/abnormalities, multiple pregnancy or gestational age <18weeks. Thus, included in the analysis were 466 sonographic volumes of normal fetal brains from singleton pregnancies, acquired by transabdominal ( n = 170) or transvaginal (n = 296) ultrasound. The corpus callosum was visualized as a hypoechoic structure. Reference ranges were established for the following parameters: curved corpus callosal length, inner-inner corpus callosal length, outer-outer corpus callosal length, rostrum height, genu height, body height and splenium height. We observed non-linear growth and an approximately four-fold increase in all corpus callosal lengths, a three-fold increase in rostrum height, a four-fold increase in genu height, a two-fold increase in body height and a three-fold increase in splenium height between 18 and 41weeks. The growth patterns of rostrum and body height appeared to be similar: there was rapid development until 24 and 22weeks of gestation, respectively, and growth slowed beyond this period. The growth patterns of genu and splenium were also similar, being characterized by progressive growth throughout gestation. ConclusionsUsing 3D ultrasound, we have constructed reference charts for measurements of the corpus callosum. Knowledge of the normal growth pattern may be useful for evaluation of abnormal development of the corpus callosum, and so help in the accurate diagnosis of pathologies such as hypogenesis and dysgenesis. Copyright (c) 2013 ISUOG. Published by John Wiley & Sons Ltd.
引用
收藏
页码:691 / 698
页数:8
相关论文
共 50 条
  • [21] Three-dimensional ultrasound evaluation of fetal tooth germs
    Ulm, MR
    Kratochwil, A
    Ulm, B
    Solar, P
    Aro, G
    Bernaschek, G
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 12 (04) : 240 - 243
  • [22] Prognostic value of three-dimensional ultrasound for fetal hydronephrosis
    Wang, Junmei
    Ying, Weiwen
    Tang, Daxing
    Yang, Liming
    Liu, Dongsheng
    Liu, Yuanhui
    Pan, Jiaoe
    Xie, Xing
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2015, 9 (03) : 766 - 772
  • [23] Fetal heart volume assessment by three-dimensional ultrasound
    Chang, FM
    Hsu, KF
    Ko, HC
    Yao, BL
    Chang, CH
    Yu, CH
    Liang, TI
    Chen, HY
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1997, 9 (01) : 42 - 48
  • [24] Three-dimensional ultrasound in fetal size and growth assessment
    Hata, Toshiyuki
    Dai, Shu-Yan
    CURRENT MEDICAL IMAGING, 2008, 4 (03) : 184 - 193
  • [25] Three-dimensional ultrasound imaging of the fetal skull and face
    Tutschek, B.
    Blaas, H. -G. K.
    Abramowicz, J.
    Baba, K.
    Deng, J.
    Lee, W.
    Merz, E.
    Platt, L.
    Pretorius, D.
    Timor-Tritsch, I. E.
    Gindes, L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2017, 50 (01) : 7 - 16
  • [26] Biometry of the pubovisceral muscle and levator hiatus by three-dimensional pelvic floor ultrasound
    Dietz, HP
    Shek, C
    Clarke, B
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 25 (06) : 580 - 585
  • [27] Transparent three-dimensional ultrasound in fetal malformations.
    Meinel, K
    Guntermann, E
    ULTRASCHALL IN DER MEDIZIN, 1998, 19 (03): : 120 - 125
  • [28] Fetal dental panorama on three-dimensional ultrasound imaging
    Couly, G.
    Nicot, R.
    Kverneland, B.
    Ferri, J.
    Levaillant, J. -M.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2016, 48 (04) : 541 - 543
  • [29] Three-dimensional and four-dimensional ultrasound applications in fetal medicine
    Yagel, Simcha
    Cohen, Sarah M.
    Messing, Baruch
    Valsky, Dan V.
    CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2009, 21 (02) : 167 - 174
  • [30] The assessment of fetal neurobehavior by three-dimensional and four-dimensional ultrasound
    Kurjak, Asim
    Tikvica, Ana
    Stanojevic, Milan
    Miskovic, Berivoj
    Ahmed, Baldreldeen
    Azumendi, Guillermo
    Di Renzo, Gian Carlo
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2008, 21 (10): : 675 - 684