Biometry of the fetal corpus callosum by three-dimensional ultrasound

被引:65
|
作者
Pashaj, S. [1 ,2 ]
Merz, E. [2 ]
Wellek, S. [3 ]
机构
[1] Matern Hosp, Tirana 1000, Albania
[2] Krankenhaus NW Frankfurt, Ctr Prenatal Diag & Therapy, Frankfurt, Germany
[3] Johannes Gutenberg Univ Mainz, Dept Med Biostat Epidemiol & Informat, D-55122 Mainz, Germany
关键词
biometric measurements; body; corpus callosal length; fetus; genu; neurosonography; rostrum; splenium; BRAIN; DIAGNOSIS; 2ND; 3D;
D O I
10.1002/uog.12501
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
ObjectivesTo construct reference ranges of quantitative characteristics of the fetal corpus callosum. MethodsWomen referred to a tertiary center for sonographic examination were recruited to undergo a detailed fetal scan from 17 to 41weeks of gestation. Three-dimensional (3D) sonographic volumes of normal fetal brains were acquired and analyzed offline. We obtained three different measurements of the corpus callosal length, as well as the height (/thickness) of its segments, namely the rostrum, genu, body and splenium. ResultsInitially we recruited 604 pregnant women, of whom 138 were excluded because of various disorders/abnormalities, multiple pregnancy or gestational age <18weeks. Thus, included in the analysis were 466 sonographic volumes of normal fetal brains from singleton pregnancies, acquired by transabdominal ( n = 170) or transvaginal (n = 296) ultrasound. The corpus callosum was visualized as a hypoechoic structure. Reference ranges were established for the following parameters: curved corpus callosal length, inner-inner corpus callosal length, outer-outer corpus callosal length, rostrum height, genu height, body height and splenium height. We observed non-linear growth and an approximately four-fold increase in all corpus callosal lengths, a three-fold increase in rostrum height, a four-fold increase in genu height, a two-fold increase in body height and a three-fold increase in splenium height between 18 and 41weeks. The growth patterns of rostrum and body height appeared to be similar: there was rapid development until 24 and 22weeks of gestation, respectively, and growth slowed beyond this period. The growth patterns of genu and splenium were also similar, being characterized by progressive growth throughout gestation. ConclusionsUsing 3D ultrasound, we have constructed reference charts for measurements of the corpus callosum. Knowledge of the normal growth pattern may be useful for evaluation of abnormal development of the corpus callosum, and so help in the accurate diagnosis of pathologies such as hypogenesis and dysgenesis. Copyright (c) 2013 ISUOG. Published by John Wiley & Sons Ltd.
引用
收藏
页码:691 / 698
页数:8
相关论文
共 50 条
  • [1] Prospective assessment of reproducibility of three-dimensional ultrasound for fetal biometry
    Grandjean, G. Ambroise
    Berveiller, P.
    Hossu, G.
    Noble, P.
    Chamagne, M.
    Morel, O.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (7-8) : 481 - 487
  • [2] Accuracy of automated three-dimensional ultrasound imaging technique for fetal head biometry
    Pluym, I. D.
    Afshar, Y.
    Holliman, K.
    Kwan, L.
    Bolagani, A.
    Mok, T.
    Silver, B.
    Ramirez, E.
    Han, C. S.
    Platt, L. D.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2021, 57 (05) : 798 - 803
  • [3] Fetal biometry by an inexperienced operator using two- and three-dimensional ultrasound
    Yang, F.
    Leung, K. Y.
    Lee, Y. P.
    Chan, H. Y.
    Tang, M. H. Y.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 35 (05) : 566 - 571
  • [4] Three-dimensional fetal ultrasound
    Blaas, HGK
    Eik-Nes, SH
    Berg, S
    BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2000, 14 (04) : 611 - 627
  • [5] Obstetrical three-dimensional ultrasound in the visualization of the intracranial midline and corpus callosum of fetuses with cephalic position
    Wang, PH
    Ying, TH
    Wang, PC
    Shih, IC
    Lin, LY
    Chen, GD
    PRENATAL DIAGNOSIS, 2000, 20 (06) : 518 - 520
  • [6] Assessment of the corpus callosum at 20-24 weeks' gestation by three-dimensional ultrasound examination
    Plasencia, W.
    Dagklis, T.
    Borenstein, M.
    Csapo, B.
    Nicolaides, K. H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2007, 30 (02) : 169 - 172
  • [7] Assessment of length and area of corpus callosum by three-dimensional ultrasonography
    Visentainer, Milena
    Junior, Edward Araujo
    Rolo, Liliam Cristine
    Machado Nardozza, Luciano Marcondes
    Moron, Antonio Fernandes
    REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRICIA, 2010, 32 (12): : 573 - 578
  • [8] Three-dimensional sagittal reconstruction of the corpus callosum:: fact or artifact?
    Malinger, G.
    Lerman-Sagie, T.
    Vinals, F.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 28 (05) : 742 - 743
  • [9] Three-dimensional ultrasound of the fetal spine
    Johnson, DD
    Pretorius, DH
    Riccabona, M
    Budorick, NE
    Nelson, TR
    OBSTETRICS AND GYNECOLOGY, 1997, 89 (03): : 434 - 438
  • [10] Comparison between Two-Dimensional and Three-Dimensional Assessments of the Fetal Corpus Callosum: Reproducibility of Measurements and Acquisition Time
    Pomar, Leo
    Baert, Jonathan
    Mchirgui, Ali
    Lambert, Veronique
    Carles, Gabriel
    Hcini, Najeh
    Baud, David
    Vial, Yvan
    JOURNAL OF PEDIATRIC NEUROLOGY, 2021, 19 (05) : 312 - 320