Performance Comparison between Two Types of Miniature Axial Flow Pumps for Children

被引:0
|
作者
Chen, Ningning [1 ]
Chang, Yu [1 ]
Gao, Bin [1 ]
Shi, Linxi [1 ]
Li, Ling [1 ]
Ma, Xinrui [1 ]
机构
[1] Beijing Univ Technol, Sch Life Sci & Bioengn, Beijing, Peoples R China
关键词
M-AFP; pump; performance; children; simulative circulation apparatus;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Miniature axial flow pump (M-AFP) is a ventricular assist device that supports the failing ventricle in advanced stage heart failure. In the past several years, we have developed two types of M-AFP aiming for children. In this paper, mechanical performance of them are tested and analyzed in order to help us find out their differences in nature. A simulative circulative apparatus is designed that can be used to quantitatively predict the mechanical characteristic parameters of the pumps and their relationship. Under the condition of load pressure invariance, we mainly test the change of blood flow with these two pumps respectively. The type A has a volume of 47ml; with external diameter of 26mm and length of 72mm. The simulative cardiac flow attains 3-4L/min under the pressure of 100mmHg, which is enough to assist the left ventricular of children. In all the two pumps, rotate speed of impeller and flow rate of blood present positive mutuality with pressure invariance. Besides, comparing with type A, the type B has smaller volume, and it is much easier for type B to increase rotate speed of the pump and comparably reduce energy consumption. Apart from the characters of smaller volume and simpler configuration, the output of miniature axial blood pump has achieved required pressure and blood flow. We still have the possibility to improve the blood pump by reducing energy consumption and increasing efficiency. The performance test and comparison in simulative circulation apparatus that is out of body is very important for improvement of blood pump. It can accelerate the development of mechanical assistant therapy and increase the cure rate of heart failure for children.
引用
收藏
页码:44 / 46
页数:3
相关论文
共 50 条
  • [41] Gas-liquid two-phase flow in the axial clearance of liquid-ring pumps
    Zhang, Renhui
    Tian, Lei
    Guo, Guangqiang
    Chen, Xuebing
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2020, 34 (02) : 791 - 800
  • [42] Development and initial performance of a miniature axial flow blood pump using magnetic fluid shaft seal
    Eiji Okamoto
    Tetsuya Yano
    Kazumitsu Sekine
    Yusuke Inoue
    Yasuyuki Shiraishi
    Tomoyuki Yambe
    Yoshinori Mitamura
    Journal of Artificial Organs, 2023, 26 : 12 - 16
  • [43] Development and initial performance of a miniature axial flow blood pump using magnetic fluid shaft seal
    Okamoto, Eiji
    Yano, Tetsuya
    Sekine, Kazumitsu
    Inoue, Yusuke
    Shiraishi, Yasuyuki
    Yambe, Tomoyuki
    Mitamura, Yoshinori
    JOURNAL OF ARTIFICIAL ORGANS, 2023, 26 (01) : 12 - 16
  • [44] Comparison between miniature periodic two-phase thermosyphons and miniature LHP applied to electronic cooling equipment
    Filippeschi, S.
    APPLIED THERMAL ENGINEERING, 2011, 31 (05) : 795 - 802
  • [45] Comparison of Two Types of Cooling of Axial Flux Permanent Magnet Machines by CFD Simulation
    Veg, Lukas
    Laksar, Jan
    2019 19TH INTERNATIONAL CONFERENCE ON ELECTRICAL DRIVES & POWER ELECTRONICS (EDPE), 2019, : 303 - 306
  • [46] Performance comparison of composite clock estimates for two types of models
    Abdellatif, Akram Amin
    Suess, Matthias
    2012 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (FCS), 2012,
  • [47] Experimental Validation of Two Types of Force Actuators: A Performance Comparison
    Jiang, Xishan
    Wang, Ning
    Zheng, Jing
    Pan, Jie
    SENSORS, 2024, 24 (12)
  • [48] Comparison of performance and patient satisfaction of two types of ERG electrodes
    Beeler, P.
    Barthelmes, D.
    Sutter, F. K.
    Helbig, H.
    Helbig, H.
    Fleischhauer, J. C.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2007, 224 (04) : 265 - 268
  • [49] Noise performance comparison between two different types of time-domain systems for microwave detection
    Zeng, Xuezhi
    Monteith, Albert
    Fhager, Andreas
    Persson, Mikael
    Zirath, Herbert
    INTERNATIONAL JOURNAL OF MICROWAVE AND WIRELESS TECHNOLOGIES, 2017, 9 (03) : 535 - 542
  • [50] The comparison of gut microbiota between different types of epilepsy in children
    Fang, Siwei
    Hu, Nanfei
    Zhou, Changci
    You, Jiajia
    Wu, Liwen
    Pan, Xiongfeng
    Xiao, Zhenghui
    Qiu, Jun
    MICROBIAL CELL FACTORIES, 2025, 24 (01)