Composite slim floor beams with innovative shear connections

被引:6
|
作者
Chen, Shiming [1 ]
Limazie, Toi [2 ]
机构
[1] Tongji Univ, Coll Civil Engn, Shanghai, Peoples R China
[2] JZFZ Architectural Design Co Ltd, Chengdu, Sichuan, Peoples R China
基金
美国国家科学基金会;
关键词
buildings; structures; design; composite structures; design methods & aids; BEHAVIOR;
D O I
10.1680/jstbu.16.00171
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An innovative form of slim floor beams is proposed in which the shear connection is formed by combining the concrete passing through the web openings with a steel tie-bar element. A numerical study was conducted to evaluate the flexural behaviour of these composite shallow cellular beams. The force transferring mechanism, load-bearing capacity and failure patterns of the shear connections were also evaluated. Two different configurations of shear connection were designed and a parametric study was carried out to determine the parameters likely to influence their performance. The findings were incorporated with bending and push-out test results to develop design methods for this form of shear connection. A tentative design procedure for the composite shallow cellular beams is proposed.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 50 条
  • [41] A method for calculation of stress of composite beams with elastic shear connections
    Zhou, Dong-Hua
    Sun, Li-Li
    Fan, Jiang
    Wang, Jun-Ping
    Gao, Qiong-Xian
    Gongcheng Lixue/Engineering Mechanics, 2011, 28 (03): : 157 - 162
  • [42] Predicting the Demand of Shear Tab Connections with Composite Beams in Fire
    Mohammad A. Hajjar
    Elie G. Hantouche
    International Journal of Steel Structures, 2020, 20 : 817 - 832
  • [43] Robustness of Composite Floor Systems with Shear Connections: Modeling, Simulation, and Evaluation
    Sadek, Fahim
    El-Tawil, Sherif
    Lew, H. S.
    JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (11) : 1717 - 1725
  • [44] Direct shear behavior of concrete filled hollow steel tube shear connector for slim-floor steel beams
    Hosseinpour, Emad
    Baharom, Shahrizan
    Badaruzzaman, Wan Hamidon W.
    Shariati, Mahdi
    Jalali, Abdolrahim
    STEEL AND COMPOSITE STRUCTURES, 2018, 26 (04): : 485 - 499
  • [45] Experimental and numerical performance of shear connections in CLT–concrete composite floor
    Khai Quang Mai
    Aron Park
    Kihak Lee
    Materials and Structures, 2018, 51
  • [46] Nonlinear behaviour of unprotected composite slim floor steel beams exposed to different fire conditions
    Ellobody, Ehab
    THIN-WALLED STRUCTURES, 2011, 49 (06) : 762 - 771
  • [47] Design of semi-continuous non-sway composite frames with slim floor beams
    Bernuzzi, C
    Zandonini, R
    5TH INTERNATIONAL COLLOQUIUM ON STABILITY OF METAL STRUCTURES - NORTH AMERICAN SESSION IN CONJUNCTION WITH ASCE STRUCTURES CONGRESS: FUTURE DIRECTION IN STABILITY RESEARCH & DESIGN, PROCEEDINGS, 1996, : 73 - 82
  • [48] Composite steel-concrete systems with slim floor beams: structural performance and design considerations
    Zandonini, R
    Gadotti, F
    Fedrizzi, E
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 35 - 44
  • [49] The behaviour of asymmetric slim floor steel beams in fire
    Bailey, CG
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1999, 50 (03) : 235 - 257
  • [50] Behaviour of asymmetric slim floor steel beams in fire
    Bailey, C.G.
    Journal of Constructional Steel Research, 50 (03): : 235 - 257