Calibration of the CMS hadron calorimeter in Run 2

被引:1
|
作者
Chadeeva, M. [1 ,2 ]
Lychkovskaya, N. [3 ]
机构
[1] NRNU MEPhI, 31 Kashirskoe Shosse, Moscow, Russia
[2] PN Lebedev Phys Inst, 53 Leninsky Prospect, Moscow, Russia
[3] ITEP, 25 B Cheremushkinskaya, Moscow, Russia
来源
关键词
Calorimeters; Detector alignment and calibration methods (lasers; sources; particle-beams); Performance of High Energy Physics Detectors;
D O I
10.1088/1748-0221/13/03/C03025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Various calibration techniques for the CMS Hadron calorimeter in Run 2 and the results of calibration using 2016 collision data are presented. The radiation damage corrections, inter-calibration of different channels using the phi-symmetry technique for barrel, endcap and forward calorimeter regions are described, as well as the intercalibration with muons of the outer hadron calorimeter. The achieved intercalibration precision is within 3%. The in situ energy scale calibration is performed in the barrel and endcap regions using isolated charged hadrons and in the forward calorimeter using the Z -> ee process. The impact of pileup and the developed technique of correction for pileup is also discussed. The achieved uncertainty of the response to hadrons is 3.4% in the barrel and 2.6% in the endcap region (at the pseudorapidity range vertical bar eta vertical bar < 2) and is dominated by the systematic uncertainty due to pileup contributions.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Calibration strategy of CMS electromagnetic calorimeter
    Paramatti, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 22 - 23
  • [32] Calibration of the Electromagnetic Calorimeter of the CMS experiment
    Argiro, S.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2009, 197 : 362 - 365
  • [33] Calibration of the CMS Electromagnetic Calorimeter at the LHC
    Leslie, D. E.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1196 - 1198
  • [34] CMS electromagnetic calorimeter calibration and alignment
    Wamorkar, Tanvi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 121 - 123
  • [35] Calibration of the electromagnetic calorimeter of the CMS experiment
    Tabarelli de Fatis, T.
    XIII INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2009, 160
  • [36] Calibration of a digital hadron calorimeter with muons
    Bilki, B.
    Butler, J.
    Cundiff, T.
    Drake, G.
    Haberichtera, W.
    Hazen, E.
    Hoff, J.
    Holm, S.
    Kreps, A.
    May, E.
    Mavromanolakis, G.
    Norbeck, E.
    Northacker, D.
    Onel, Y.
    Repond, J.
    Underwood, D.
    Wu, S.
    Xia, L.
    JOURNAL OF INSTRUMENTATION, 2008, 3
  • [37] The CMS Calorimeter Trigger for LHC Run II
    Bundock, Aaron
    17TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2016), 2017, 928
  • [38] Photodetector power supply system for the CMS hadron calorimeter
    Dimitrov, L
    Elias, JE
    Kunov, B
    Sergueev, S
    Ronzhin, A
    Vankov, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 553 (03): : 448 - 454
  • [39] Phase 1 upgrade of the CMS Hadron Barrel Calorimeter
    Isik, Candan
    CMS Collaboration
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1042
  • [40] Front end readout electronics for the CMS Hadron Calorimeter
    Shaw, TM
    Baumbaugh, A
    Boubekeur, A
    Elias, JE
    Hoff, J
    Holm, S
    Los, S
    Rivetta, C
    Ronzhin, A
    Whitmore, J
    Zimmerman, T
    Yarema, RJ
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 194 - 197