Radioluminescence dosimetry by scintillating fiber optics: the open challenges

被引:3
|
作者
Veronese, Ivan [1 ]
Cantone, Marie Claire [1 ]
Chiodini, Norberto [2 ]
De Mattia, Cristina [1 ]
Fasoli, Mauro [2 ]
Mones, Eleonora [3 ]
Vedda, Anna [2 ]
机构
[1] Univ Milan, Dipartimento Fis, Via Celoria 16, I-20133 Milan, Italy
[2] Univ Milano Bicocca, Dipartimento Sci Mat, I-20125 Milan, Italy
[3] Azienda Osped Maggiore della Carita, Med Phys Dept, I-28100 Novara, Italy
来源
HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XV | 2013年 / 8852卷
关键词
Scintillating fibers; europium; radiation therapy; stem effect; memory effect; CERENKOV RADIATION; RADIOTHERAPY; ELECTRON; DETECTOR;
D O I
10.1117/12.2027041
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the last decade, the interest in scintillating fiber optics for ionizing radiation monitoring is constantly increasing. Among the fields of possible applications of these sensors, radiation therapy represents a driving force for the research and development of new devices. In fact, the small dimensions of fiber optics based detectors, together with their realtime response, make these systems extremely promising both in quality assurance measurements of intensity modulated radiotherapy beams, and in in- vivo dosimetry. On the other hand, two specific aspects might represent limiting factors: (i) the "stem effect", that is the spurious luminescence originating as a consequence of the irradiation of the light guide, and (ii) the "memory effect", that is the radioluminescence sensitivity increase during prolonged exposition to ionizing radiation, typical of many scintillating materials. These two issues, representing the main challenges to face for the effective use of scintillating fiber as dosimeters in radiotherapy, were studied considering amorphous silica matrices prepared by sol- gel method and doped with europium. The origin of the stem effect was investigated by means of spectral measurements of the doped fibers irradiated with Xrays and electrons of different energies, field sizes and orientations. New approaches for removing the stem effect on the basis of the radioluminescent spectral analysis are presented and discussed. Furthermore, the causes and phenomenology of the memory effect are described, considering also the effect of dose accumulation with different dose rates and energies of ionizing radiation.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Scintillating fiber dosimeter
    Frelin, AM
    Fontbonne, JM
    Ban, G
    Batalla, A
    Colin, J
    Isambert, A
    Labalme, M
    Leroux, T
    Vela, A
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2221 - 2225
  • [32] Low dose and low dose rate radioluminescence dosimetry
    Bradley, D. A.
    Essa, R. Z.
    Peh, Suat-Cheng
    Teow, Sin-Yeang
    Chew, Ming-Tsuey
    Zubair, H. T.
    Oresegun, Adebiyi
    Basaif, Azmi
    Choo, Kan Yeep
    Ibrahim, Siti A.
    Abdul-Rashid, Hairul Azhar
    APPLIED RADIATION AND ISOTOPES, 2023, 198
  • [33] Aspects of Infrared Radioluminescence dosimetry in K-feldspar
    Varma, Vaidehi
    Biswas, Rabiul H.
    Singhvi, Ashok K.
    GEOCHRONOMETRIA, 2013, 40 (04) : 266 - 273
  • [34] Optical dosimetry for ionizing radiation fields by infrared radioluminescence
    Shikama, T.
    Toh, K.
    Nagata, S.
    Tsuchiya, B.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (05) : 1103 - 1106
  • [35] Optical dosimetry for ionizing radiation fields by infrared radioluminescence
    Shikama, T
    Toh, K
    Nagata, S
    Tsuchiya, B
    17th International Conference on Optical Fibre Sensors, Pts 1 and 2, 2005, 5855 : 507 - 510
  • [36] Scintillating optical fibre sensor for radiotherapy dosimetry
    McCarthy, D.
    O'Keeffe, S.
    Woulfe, P.
    Cronin, J.
    Lewis, E.
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [37] Medical proton dosimetry using radioluminescence from aluminium oxide crystals attached to optical-fiber cables
    Andersen, C. E.
    Edmund, J. M.
    Medin, J.
    Grusell, E.
    Jain, M.
    Mattsson, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 466 - 468
  • [38] Challenges to the air transport industry for implementing fiber optics
    Martinec, Daniel
    2006 IEEE Avionics, Fiber-Optics and Photonics Technology Conference, 2006, : 1 - 2
  • [39] Fiber-coupled Al2O3:C radioluminescence dosimetry for total body irradiations
    Buranurak, S.
    Andersen, C. E.
    RADIATION MEASUREMENTS, 2016, 93 : 46 - 54
  • [40] Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry
    Lee, Bongsoo
    Jang, Kyoung Won
    Cho, Dong Hyun
    Yoo, Wook Jae
    Tack, Gye-Rac
    Chung, Soon-Cheol
    Kim, Sin
    Choc, Hyosung
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 344 - 348