Radioluminescence dosimetry by scintillating fiber optics: the open challenges

被引:3
|
作者
Veronese, Ivan [1 ]
Cantone, Marie Claire [1 ]
Chiodini, Norberto [2 ]
De Mattia, Cristina [1 ]
Fasoli, Mauro [2 ]
Mones, Eleonora [3 ]
Vedda, Anna [2 ]
机构
[1] Univ Milan, Dipartimento Fis, Via Celoria 16, I-20133 Milan, Italy
[2] Univ Milano Bicocca, Dipartimento Sci Mat, I-20125 Milan, Italy
[3] Azienda Osped Maggiore della Carita, Med Phys Dept, I-28100 Novara, Italy
来源
HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XV | 2013年 / 8852卷
关键词
Scintillating fibers; europium; radiation therapy; stem effect; memory effect; CERENKOV RADIATION; RADIOTHERAPY; ELECTRON; DETECTOR;
D O I
10.1117/12.2027041
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In the last decade, the interest in scintillating fiber optics for ionizing radiation monitoring is constantly increasing. Among the fields of possible applications of these sensors, radiation therapy represents a driving force for the research and development of new devices. In fact, the small dimensions of fiber optics based detectors, together with their realtime response, make these systems extremely promising both in quality assurance measurements of intensity modulated radiotherapy beams, and in in- vivo dosimetry. On the other hand, two specific aspects might represent limiting factors: (i) the "stem effect", that is the spurious luminescence originating as a consequence of the irradiation of the light guide, and (ii) the "memory effect", that is the radioluminescence sensitivity increase during prolonged exposition to ionizing radiation, typical of many scintillating materials. These two issues, representing the main challenges to face for the effective use of scintillating fiber as dosimeters in radiotherapy, were studied considering amorphous silica matrices prepared by sol- gel method and doped with europium. The origin of the stem effect was investigated by means of spectral measurements of the doped fibers irradiated with Xrays and electrons of different energies, field sizes and orientations. New approaches for removing the stem effect on the basis of the radioluminescent spectral analysis are presented and discussed. Furthermore, the causes and phenomenology of the memory effect are described, considering also the effect of dose accumulation with different dose rates and energies of ionizing radiation.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] FIBER OPTICS DOSIMETRY
    KRONENBERG, S
    SIEBENTRITT, CR
    NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (01): : 109 - 111
  • [2] Scintillating fiber camera for neutron dosimetry in spacecraft
    Terasawa, K
    Doke, T
    Hasebe, N
    Kikuchi, J
    Kudo, K
    Murakami, T
    Takeda, N
    Tamura, T
    Torii, S
    Yamashita, M
    Yoshihira, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 457 (03): : 499 - 508
  • [3] Radioluminescence fiber optic and imaging dosimetry in radiation therapy
    Darafsheh, Arash
    OPTICAL SENSING AND DETECTION VIII, 2024, 12999
  • [4] Scintillating Optical Fiber Dosimetry with Photodiode Readout
    Rego, Florbela
    Peralta, Luis
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 310 - 312
  • [5] SCINTILLATING FIBER OPTICS AND THEIR APPLICATION IN RADIOGRAPHIC SYSTEMS
    SHAO, H
    MILLER, DW
    PEARSALL, CR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 845 - 857
  • [6] Novel scintillating fiber optics for digital radiography
    Chirco, P
    Zanarini, M
    Rabini, M
    Zambelli, G
    Giacometti, M
    Querzola, E
    Rossi, M
    Casali, F
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS, OPTICS, AND APPLICATIONS, 1997, 3115 : 2 - 9
  • [7] Evaluation of an optical scintillating fiber detector for CT dosimetry
    Gillet, Pierre
    Munier, Melodie
    Arbor, Nicolas
    Carbillet, Fanny
    El Bitar, Ziad
    RADIATION MEASUREMENTS, 2018, 119 : 125 - 131
  • [8] Recent progresses in scintillating doped silica fiber optics
    De Mattia, Cristina
    Mones, Eleonora
    Veronese, Ivan
    Fasoli, Mauro
    Chiodini, Norberto
    Cantone, Marie Claire
    Vedda, Anna
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XVI, 2014, 9213
  • [9] In Vivo Dosimetry for HDR Brachytherapy Using a Scintillating Fiber Dosimeter
    Therriault-Proulx, F.
    Villeneuve, M.
    Martin, A.
    Gingras, L.
    Beddar, S.
    Beaulieu, L.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [10] PULSED BEAM DOSIMETRY USING FIBER-COUPLED RADIOLUMINESCENCE DETECTORS
    Andersen, Claus E.
    MEDICAL PHYSICS IN THE BALTIC STATES, 2012, : 19 - 22