Horizontal pullout capacity of a group of two vertical plate anchors in clay

被引:0
|
作者
Bhattacharya, Paramita [1 ]
Kumar, Jyant [2 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Kharagpur 721302, W Bengal, India
[2] Indian Inst Sci, Dept Civil Engn, Bangalore 560012, Karnataka, India
关键词
anchors; clays; failure; finite elements; limit analysis; pullout load; FOOTING WIDTH; STABILITY;
D O I
10.12989/gae.2013.5.4.299
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The horizontal pullout capacity of a group of two vertical strip plate anchors, placed along the same vertical plane, in a fully cohesive soil has been computed by using the lower bound finite element limit analysis. The effect of spacing between the plate anchors on the magnitude of total group failure load (P-uT) has been evaluated. An increase of soil cohesion with depth has also been incorporated in the analysis. For a weightless medium, the total pullout resistance of the group becomes maximum corresponding to a certain optimum spacing between the anchor plates which has been found to vary generally between 0.5B and B; where B is the width of the anchor plate. As compared to a single plate anchor, the increase in the pullout resistance for a group of two anchors becomes greater at a higher embedment ratio. The effect of soil unit weight has also been analyzed. It is noted that the interference effect on the pullout resistance increases further with an increase in the unit weight of soil mass.
引用
收藏
页码:299 / 312
页数:14
相关论文
共 50 条
  • [21] Seismic pullout capacity of vertical anchors in sand
    Bhattacharya, Paramita
    Kumar, Jyant
    GEOMECHANICS AND GEOENGINEERING-AN INTERNATIONAL JOURNAL, 2013, 8 (03): : 191 - 201
  • [22] MODEL TESTS FOR PULLOUT RESISTANCE OF VERTICAL ANCHORS IN CLAY
    DAS, BM
    TARQUIN, AJ
    MORENO, R
    CIVIL ENGINEERING FOR PRACTICING AND DESIGN ENGINEERS, 1985, 4 (02): : 191 - 209
  • [23] Vertical Uplift Resistance of Two Interfering Horizontal Anchors in Clay
    Sahoo, Jagdish Prasad
    Kumar, Jyant
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2014, 140 (04)
  • [24] Vertical pullout capacity of a group of helical screw anchors in sand: An empirical approach
    Mittal S.
    Mukherjee S.
    Indian Geotechnical Journal, 2014, 44 (4) : 480 - 488
  • [25] Vertical uplift capacity of a group of shallow horizontal anchors in sand
    Kumar, J.
    Kouzer, K. M.
    GEOTECHNIQUE, 2008, 58 (10): : 821 - 823
  • [26] The pullout capacity of OMNI-Max anchors in clay
    Yang, Yancheng
    Liu, Haixiao
    Zhao, Yanbing
    OCEAN ENGINEERING, 2021, 230
  • [27] Pullout capacity of circular multi-plate vertical anchors in sand - An experimental study
    Tilak, Vidya B.
    Samadhiya, Narendra Kumar
    OCEAN ENGINEERING, 2022, 258
  • [28] Horizontal pullout capacity of embedded suction anchors in sand
    Bang, S.
    Jones, K.
    Kim, Y. S.
    Kim, K. O.
    Cho, Y.
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON OFFSHORE MECHANICS AND ARCTIC ENGINEERING, VOL 2, 2006, : 11 - 17
  • [29] New analytical formulas to estimate the pullout capacity factor for rectangular plate anchors in NC clay
    Liu, Jun
    Tan, Mengxi
    Hu, Yuxia
    APPLIED OCEAN RESEARCH, 2018, 75 : 234 - 247
  • [30] Pullout capacity of inclined plate anchors embedded in sand
    Bhattacharya, Paramita
    Kumar, Jyant
    CANADIAN GEOTECHNICAL JOURNAL, 2014, 51 (11) : 1365 - 1370