Full-field digital mammography designed as a complete system

被引:70
|
作者
Muller, S [1 ]
机构
[1] GE Med Syst, F-78533 Buc, France
关键词
breast imaging; digital mammography; image quality;
D O I
10.1016/S0720-048X(99)00066-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Although mammography is currently considered by many to be the best tool for the early detection of breast cancer, conventional film-screen imaging is still far from perfect. A fundamental limitation of film-screen mammography is the fact that the detection, display and storage devices are one and the same, making it impossible to separately optimize each device. In addition to a potentially equivalent or better image quality compared to the film-screen technology, full-field digital mammography (FFDM) will provide the radiologist with numerous advantages: digital image management, digital data transfer and new medical applications. Nevertheless, to fulfil the potential of digital mammography, an FFDM unit must not only provide an outstanding technology for X-ray detection, but should be designed as a complete system. Each component of the FFDM system should be designed to provide or to increase the current image quality, the current ease of use and the current throughput: the X-ray tube, the gantry, the image receptor packaging, the detector, the acquisition electronics, the softcopy review workstation, the user interface, as well as the network capabilities. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:25 / 34
页数:10
相关论文
共 50 条
  • [1] Full-field digital mammography
    Bick, U
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 957 - 964
  • [2] Full-field digital mammography
    U Bick
    [J]. Breast Cancer Research, 2 (Suppl 2)
  • [3] Digital Mammography Versus Full-Field Digital Mammography
    Hall, Ferris M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : 240 - 240
  • [4] Comparison of slot scanning digital mammography system with full-field digital mammography system
    Lai, Chao-Jen
    Shaw, Chris C.
    Geiser, William
    Chen, Lingyun
    Arribas, Elsa
    Stephens, Tanya
    Davis, Paul L.
    Ayyar, Geetha P.
    Dogan, Basak E.
    Nguyen, Victoria A.
    Whitman, Gary J.
    Yang, Wei T.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2339 - 2346
  • [5] Physical characteristics of a full-field digital mammography system
    Suryanarayanan, S
    Karellas, A
    Vedantham, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 533 (03): : 560 - 570
  • [6] DQE evaluation of a full-field digital mammography system
    Roehrig, H
    Gandhi, K
    Fan, JH
    Poolla, A
    Mimura, S
    [J]. PENETRATING RADIATION SYSTEMS AND APPLICATIONS VI, 2004, 5541 : 141 - 152
  • [7] Comparison of full-field digital mammography with CR mammography
    Uchiyama, N
    Kobayashi, H
    Tajima, H
    Machida, M
    Kumazaki, T
    Moriyama, N
    [J]. RADIOLOGY, 2002, 225 : 119 - 119
  • [8] Full-field digital mammography - System development and technical performance
    Yaffe, MJ
    Plewes, DB
    Mawdsley, GE
    Critten, J
    Feig, SA
    Maidment, ADA
    Picarro, M
    Tesic, M
    [J]. DIGITAL MAMMOGRAPHY '96, 1996, 1119 : 125 - 131
  • [9] Development of a quality control system for full-field digital mammography
    Yaffe, MJ
    Williams, MB
    Niklason, LT
    Mawdsley, GE
    Maidment, AD
    [J]. RADIOLOGY, 1998, 209P : 160 - 160
  • [10] Comparison of Radiologist Performance with Photon-Counting Full-Field Digital Mammography to Conventional Full-Field Digital Mammography
    Cole, Elodia B.
    Toledano, Alicia Y.
    Lundqvist, Mats
    Pisano, Etta D.
    [J]. ACADEMIC RADIOLOGY, 2012, 19 (08) : 916 - 922