Pulsed hot-wire measurements in two- and three-dimensional wall jets

被引:33
|
作者
Venås, B
Abrahamsson, H
Krogstad, PÅ [1 ]
Löfdahl, L
机构
[1] Norwegian Univ Sci & Technol, N-7034 Trondheim, Norway
[2] Chalmers Univ Technol, S-41296 Gothenburg, Sweden
关键词
D O I
10.1007/s003480050346
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Pulsed Hot-Wire Anemometry (PHWA) measurements are performed in well defined two- and three-dimensional turbulent wall jets. For the two-dimensional wall jet the objective is to study reported differences between conventional Hot-Wire Anemometry (HWA) and Laser Doppler Anemometry (LDA) results. In the three dimensional wall jet, new improved data are provided, employing a measuring technique suitable for highly turbulent flows. This, since only hot-wire results previously have been published for this flow. The pulsed wire results show good agreement with existing Laser Doppler anemometer data in the two-dimensional wall jet, both reporting significantly higher turbulence levels in the outer region of the flow than hot-wires do. The hot-wire anemometer errors generally increase with increasing local turbulence intensity and since the three-dimensional wall jet has a higher turbulence level than its two-dimensional equivalent, the new pulsed hot-wire results improve the information available for the turbulence field in this flow significantly.
引用
收藏
页码:210 / 218
页数:9