Assessment of iterative image reconstruction techniques for small-animal PET imaging applications

被引:0
|
作者
Karali, E. [1 ]
Pavlopoulos, S. [1 ]
Koutsouris, D. [1 ]
机构
[1] Natl Tech Univ Athens, Dept Elect & Comp Engn, Biomed Engn Lab, Athens, Greece
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is to assess the performance of iterative reconstruction methods, using phantom data from a prototype small-animal PET system. The algorithms compared are the simultaneous versions of ART (SART), EM-ML, ISRA WLS and a new iterative algorithm we have introduced under the short name ISWLS. The evaluation study was based on reconstructed image quality, as it is derived from visual inspection, cross-correlation coefficient and CNRs (contrast-to-noise ratios) of specific ROIs (region-of-interest). In general EM-ML and ISRA present similar reconstruction time and minor differences in reconstructed image quality. Slightly superior performances show WLS and SART while ISWLS improves reconstruction resolution at the edges of the field of view.
引用
收藏
页码:948 / 953
页数:6
相关论文
共 50 条
  • [31] Small-Animal PET/CT Assessment of Bone Microdamage in Ovariectomized Rats
    Li, Zhan-Chun
    Jiang, Sheng-Dan
    Yan, Jun
    Jiang, Lei-Sheng
    Dai, Li-Yang
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (05) : 769 - 775
  • [32] The future of hybrid imaging—part 3: PET/MR, small-animal imaging and beyond
    Thomas Beyer
    Lutz S. Freudenberg
    Johannes Czernin
    David W. Townsend
    [J]. Insights into Imaging, 2011, 2 (3) : 235 - 246
  • [33] Iterative image reconstruction techniques: Applications for cardiac CT
    Renker, Matthias
    Ramachandra, Ashok
    Schoepf, U. Joseph
    Raupach, Rainer
    Apfaltrer, Paul
    Rowe, Garrett W.
    Vogt, Sebastian
    Flohr, Thomas G.
    Kerl, J. Matthias
    Bauer, Ralf W.
    Fink, Christian
    Henzler, Thomas
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (04) : 225 - 230
  • [34] Performance evaluation of fast iterative pet image reconstruction techniques
    Bellemann, ME
    Schmidlin, P
    Brix, G
    Doll, J
    Haberkorn, U
    Strauss, LG
    Lorenz, WJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 677 - 677
  • [35] Applications of Small Animal Imaging with PET, PET/CT, and PET/MR Imaging
    Nanni, Cristina
    Torigian, Drew A.
    [J]. PET CLINICS, 2008, 3 (03) : 243 - +
  • [36] Techniques necessary for multiple tracer quantitative small-animal imaging studies
    Sharp, TL
    Dence, CS
    Engelbach, JA
    Herrero, P
    Gropler, RJ
    Welch, MJ
    [J]. NUCLEAR MEDICINE AND BIOLOGY, 2005, 32 (08) : 875 - 884
  • [37] Contribution of normalization to image noise for the Siemens Inveon small-animal PET scanner
    Visser, Eric P.
    Disselhorst, Jonathan A.
    Laverman, Peter
    Gotthardt, Martin
    Oyen, Wim J. G.
    Boerman, Otto C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 605 (03): : 433 - 435
  • [38] Scanning multiple mice in a small-animal PET scanner: Influence on image quality
    Siepel, Francoise J.
    van Lier, Monique G. J. T. B.
    Chen, Mu
    Disselhorst, Jonathan A.
    Meeuwis, Antoi P. W.
    Oyen, Wim J. G.
    Boerman, Otto C.
    Visser, Eric P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 605 - 610
  • [39] Scanning Multiple Mice in a Small-Animal PET Scanner: Influence on Image Quality
    Disselhorst, J. A.
    Siepel, F. J.
    van Lier, M. G. J. T.
    Chen, M.
    Meeuwis, A. P. W.
    Oyen, W. J. G.
    Boerman, O. C.
    Visser, E. P.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S294 - S294
  • [40] Longitudinal correlations in a small-animal PET studies
    Abbey, C
    Borowsky, A
    Gregg, J
    McGoldrick, E
    Cardiff, R
    Cherry, S
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1901 - 1901