Pretreatment Method for Immunoassay of Polychlorinated Biphenyls in Transformer Oil Using Multi layer Capillary Column and Microfluidic Liquid-Liquid Partitioning

被引:3
|
作者
Aota, Arata [1 ]
Date, Yasumoto [1 ,2 ]
Terakado, Shingo [1 ]
Ohmura, Naoya [1 ]
机构
[1] Cent Res Inst Elect Power Ind, Environm Sci Res Lab, Abiko, Chiba 2701194, Japan
[2] Tohoku Univ, Grad Sch Environm Studies, Aoba Ku, Sendai, Miyagi 9808579, Japan
关键词
PCBS;
D O I
10.2116/analsci.29.393
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polychlorinated biphenyls (PCBs) are persistent organic pollutants that are present in the insulating oil inside a large number of transformers. To aid in eliminating PCB-Contaminated transformers, PCBs in oil need to be measured using a rapid and cost-effective analytical method. We previously reported a pretreatment method for the immunoassay of PCBs in oil using a large-scale multilayer column and a microchip with multiple microrecesses, which permitted concentrated solvent extraction. In this paper, we report on a more rapid and facile pretreatment method, without an evaporation process, by improving the column and the microchip. In a miniaturized column, the decomposition and separation of oil were completed in 2 min. PCBs can be eluted from the capillary column at concentrations seven-times higher than those from the previous column. The total volume of the microrecesses was increased by improving the microrecess structure, the enabling extraction of four-times the amount of PCBs achieved with the previous system. By interfacing the capillary column with the improved microchip, PCBs in the eluate from the column were extracted into dimethyl sulfoxide in microrecesses with high enrichment and without the need for evaporation. Pretreatment was completed within 20 min The pretreated oil was analyzed using a flow-based kinetic exclusion immunoassay. The limit of detection of PCBs in oil was 0.15 mg kg(-1), which satisfies the criterion set in Japan of 0.5 mg kg(-1).
引用
收藏
页码:393 / 399
页数:7
相关论文
共 50 条
  • [41] DETERMINATION OF ESTROGENIC HORMONES IN WATER SAMPLES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY COMBINED WITH DISPERSIVE LIQUID-LIQUID MICRO-EXTRACTION METHOD BASED ON SOLIDIFICATION OF FLOATING ORGANIC DROP AND PRE-COLUMN DERIVATIZATION
    Liu, Jianlin
    Du, Xianyuan
    Zhang, Chen
    Lei, Yang
    Gao, Qian
    Li, Yu
    FRESENIUS ENVIRONMENTAL BULLETIN, 2011, 20 (4A): : 1075 - 1083
  • [42] Highly sensitive method for the quantification of trans-linolenic acid isomers in trilinolenin of edible oils using an ionic liquid capillary column
    Guo, Qin
    Jiang, Fan
    Jin, Jing
    Li, Qingpeng
    Wang, Feng
    Wang, Qiang
    Ha, Yiming
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2017, 97 (14) : 4697 - 4703
  • [43] Multi-residue method for determination of seven neonicotinoid insecticides in grains using dispersive solid-phase extraction and dispersive liquid-liquid micro-extraction by high performance liquid chromatography
    Wang, P.
    Yang, X.
    Wang, J.
    Cui, J.
    Dong, A. J.
    Zhao, H. T.
    Zhang, L. W.
    Wang, Z. Y.
    Xu, R. B.
    Li, W. J.
    Zhang, Y. C.
    Zhang, H.
    Jing, J.
    FOOD CHEMISTRY, 2012, 134 (03) : 1691 - 1698
  • [44] A validated UPLC-MS/MS method for the quantification of immunosuppressive drugs in peripheral blood mononuclear cells using liquid-liquid extraction with low temperature purification without complex pretreatment steps
    Wu, Lingjie
    Zhang, Xiaoying
    Liao, Naishun
    Ye, Zhenjie
    Yu, Xiaoling
    Liu, Xiaolong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 250
  • [45] Analysis of polychlorinated biphenyls in transformer oils by automated on-line coupling reversed phase liquid chromatography-gas chromatography using the through oven transfer adsorption desorption (TOTAD) Interface
    Manuel Cortes, Jose
    Andini, Juan C.
    Toledano, Rosa M.
    Quintero, Carlos
    Villen, Jesus
    Vazquez, Ana
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (04) : 461 - 471
  • [46] Ion-pair dispersive liquid-liquid microextraction solidification of floating organic droplets method for the rapid and sensitive detection of phenolic acids in wine samples using liquid chromatography combined with a core-shell particle column
    Li, Jing
    Jia, Shaodong
    Yoon, Sang Jun
    Lee, Seul Ji
    Kwon, Sung Won
    Lee, Jeongmi
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2016, 45 : 73 - 79
  • [47] Multi-Residue Method for Determination of Thirty-Five Pesticides, Pharmaceuticals and Personal Care Products in Water Using Ionic Liquid-Dispersive Liquid-Liquid Microextraction Combined with Liquid Chromatography-Tandem Mass Spectrometry
    Marube, Liziane C.
    Caldas, Sergiane S.
    dos Santos, Elisane O.
    Michaelsen, Andressa
    Primel, Ednei G.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2018, 29 (06) : 1349 - 1359
  • [48] Multi-residue method for determination of 58 pesticides, pharmaceuticals and personal care products in water using solvent demulsification dispersive liquid-liquid microextraction combined with liquid chromatography-tandem mass spectrometry
    Caldas, Sergiane Souza
    Rombaldi, Caroline
    de Oliveira Arias, Jean Lucas
    Marube, Liziane Cardoso
    Primel, Ednei Gilberto
    TALANTA, 2016, 146 : 676 - 688
  • [49] A Novel Preparation Method of Multi-Layer Graphene with High-Crystallinity Based on Liquid Exfoliation Method by Using Expandable Graphite
    Zhou, Xu-Yuan
    Guo, Yan-Pei
    Yang, Rong-Jie
    Huang, Feng-Lei
    Li, Jian-Min
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2019, 256 (08):
  • [50] The validation of a new high throughput method for determination of chloramphenicol in milk using liquid-liquid extraction with low temperature partitioning (LLE-LTP) and isotope-dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS)
    Pires do Rego, Eliane Cristina
    Guimaraes, Evelyn de Freitas
    Monteiro dos Santos, Ana Luiza
    Madureira Mothe, Elizabeth de Souza
    Rodrigues, Janaina Marques
    Pereira Netto, Annibal Duarte
    ANALYTICAL METHODS, 2015, 7 (11) : 4699 - 4707