Assessment of DFIG simplified model parameters using field test data

被引:0
|
作者
Honrubia-Escribano, A. [1 ]
Gomez-Lazaro, E. [1 ]
Vigueras-Rodriguez, A. [1 ]
Molina-Garcia, A.
Fuentes, J. A.
Muljadi, E.
机构
[1] Univ Castilla La Mancha, Renewable Energy Res Inst, Albacete 02071, Spain
关键词
Wind turbines; Generic wind models; DFIG simplified model; Power system stability; VOLTAGE DIPS; WIND POWER; VALIDATION;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper reviews and describes a simplified model of a Doubly Fed Induction Generator (DFIG) based on the IEC 61400-27 devoted to "Electrical simulation models for wind power generation". This Standard is focused on defining generic simulation models for both wind turbines (Part 1) and wind farms (Part 2). A brief summary regarding the current status of requirements and models is discussed in the paper. Additionally, parting from real field-test measurements of an operational wind turbine, parameters from Type 3 generic model IEC 61400-27 are fitted to the machine. The selected wind generator is located in a Spanish wind farm, in one of the regions with higher installed wind capacity. Electrical variables used to fit the model are shown and discussed based on previous works as well.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Identification of field model's parameters in the turbine generator end zone using measured data
    Iatcheva, I
    Stancheva, R
    OPTIMIZATION AND INVERSE PROBLEMS IN ELECTROMAGNETISM, 2003, : 277 - 286
  • [42] Uncertainty assessment of hydrologic model states and parameters: Sequential data assimilation using the particle filter
    Moradkhani, H
    Hsu, KL
    Gupta, H
    Sorooshian, S
    WATER RESOURCES RESEARCH, 2005, 41 (05) : 1 - 17
  • [43] DAMAGE ASSESSMENT OF STRUCTURES USING STATIC TEST DATA
    SANAYEI, M
    ONIPEDE, O
    AIAA JOURNAL, 1991, 29 (07) : 1174 - 1179
  • [44] Assessment of SAR using Simplified Body Representation due to RFiD Field Exposure
    Dinarevic, Enida Cero
    Poljak, Dragan
    Blazevic, Zoran
    2020 28TH INTERNATIONAL CONFERENCE ON SOFTWARE, TELECOMMUNICATIONS AND COMPUTER NETWORKS (SOFTCOM), 2020, : 279 - 282
  • [45] Damage assessment of structures using modal test data
    Hu, N
    Wang, X
    Fukunaga, H
    Yao, ZH
    Zhang, HX
    Wu, ZS
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2001, 38 (18) : 3111 - 3126
  • [46] Damage assessment of structures using static test data
    Sanayei, Masoud, 1600, (29):
  • [47] SIMPLIFIED ASSESSMENT OF MYOCARDIAL-FUNCTION USING A NEW HEART MODEL
    BAYLISS, CE
    CRAWFORD, FB
    NSAFOAH, B
    CLINICAL RESEARCH, 1977, 25 (03): : A208 - A208
  • [48] Optimal Power Control of DFIG Wind Turbines Using a Simplified Power Converter
    DanVu Nguyen
    Fujita, Goro
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [49] Aquifer parameters estimation using artesian well test data
    Ojha, CSP
    JOURNAL OF HYDROLOGIC ENGINEERING, 2004, 9 (01) : 64 - 67
  • [50] INFERENCE OF GEOACOUSTIC MODEL PARAMETERS FROM ACOUSTIC FIELD DATA