Evaluation and application of bismuth as an internal standard for the determination of lead in wines by simultaneous electrothermal atomic absorption spectrometry

被引:37
|
作者
Fernandes, KG
de Moraes, M
Neto, JAG
Nóbrega, JA
Oliveira, PV
机构
[1] Univ Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil
[2] Univ Fed Sao Carlos, Dept Quim, BR-13560970 Sao Carlos, SP, Brazil
[3] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, Brazil
关键词
D O I
10.1039/b105309b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the direct determination of Pb in wines by simultaneous multi-element atomic absorption spectrometry (SIMAAS) using a transversely heated graphite atomizer, Zeeman-effect background corrector and internal standardization is proposed. Bismuth was used as an internal standard and Pd(NO3)(2) plus Mg(NO3)(2) as chemical modifier,to stabilize both the analyte and the internal standard. The implementation of two pyrolysis steps avoided any build-up of carbonaceous residues on the graphite platform. All diluted samples (1 + 1 v/v) in 0.2% v/v HNO3 and reference solutions (5.0-50 mug l(-1) Ph in 0.2% v/v HNO3) were spiked with 25 mug l(-1) Bi. For a 20 mul aliquot dispensed into the graphite tube, a good correlation (r = 0.9997) was obtained between the ratio of the analyte signal to the internal standard signal and the analyte concentration of the reference solutions. The electrothermal behaviour of Pb and Bi in red, white and rose wines were compared. In addition, absorbance variations due to changes in experimental conditions, such as atomizer temperature, integration time, injected sample volume, radiation beam intensity, graphite tube surface, dilution and sample composition, were minimized by using Bi as internal standard. Relative standard deviations of measurements based on integrated absorbance varied from 0.1 to 3.4% and from 0.5 to 7.3% (n = 12) with and without internal standard correction, respectively. Good recoveries (91-104%) for Pb spikes were obtained. The characteristic mass was 45 pg Pb and the limit of detection based on integrated absorbance was 0.9 mug l(-1) Pb. Internal standardization increased the lifetime of the tube by 25%. Direct determinations of Pb in wines with and without internal standardization approaches were in agreement at the 95% confidence level. The repeatability and the tube lifetime were improved when using Bi as internal standard. The improvement in accuracy using an internal standard was only observed when the analytical results were affected by errors.
引用
下载
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [21] Simultaneous determination of manganese and selenium in serum by electrothermal atomic absorption spectrometry
    Correia, PRM
    de Oliveira, E
    Oliveira, PV
    TALANTA, 2002, 57 (03) : 527 - 535
  • [22] Determination of lead and cadmium in urine by electrothermal atomization atomic absorption spectrometry
    Vasil'eva, L. A.
    Grinshtein, I. L.
    Gucer, S.
    Izgi, B.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (07) : 649 - 654
  • [23] Direct determination of lead in human milk by electrothermal atomic absorption spectrometry
    Falomir, P
    Alegría, A
    Barberá, R
    Farré, R
    Lagarda, MJ
    FOOD CHEMISTRY, 1999, 64 (01) : 111 - 113
  • [24] Determination of lead in blood by tungsten coil electrothermal atomic absorption spectrometry
    Krug, FJ
    Silva, MM
    Oliveira, PV
    Nobrega, JA
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (12) : 1469 - 1474
  • [25] DETERMINATION OF LEAD IN TEETH BY ATOMIC-ABSORPTION SPECTROMETRY WITH ELECTROTHERMAL ATOMIZATION
    KEATING, AD
    KEATING, JL
    HALLS, DJ
    FELL, GS
    ANALYST, 1987, 112 (10) : 1381 - 1385
  • [26] Determination of lead and cadmium in urine by electrothermal atomization atomic absorption spectrometry
    L. A. Vasil’eva
    I. L. Grinshtein
    S. Gucer
    B. Izgi
    Journal of Analytical Chemistry, 2008, 63 : 649 - 654
  • [27] DETERMINATION OF LEAD IN LORANDITE AND MARCASITE BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    STAFILOV, T
    ALEKSOVSKA, S
    JORDANOVSKA, V
    NEUES JAHRBUCH FUR MINERALOGIE-ABHANDLUNGEN, 1994, 167 (2-3): : 401 - 408
  • [28] DETERMINATION OF LEAD IN WINES BY HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY
    CACHO, J
    FERREIRA, V
    NERIN, C
    ANALYST, 1992, 117 (01) : 31 - 33
  • [29] DETERMINATION OF LEAD IN CROATIAN WINES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY
    Tariba, Blanka
    Pizent, Alica
    Kljakovia-Gaspic, Zorana
    ARHIV ZA HIGIJENU RADA I TOKSIKOLOGIJU-ARCHIVES OF INDUSTRIAL HYGIENE AND TOXICOLOGY, 2011, 62 (01): : 25 - 31
  • [30] Determination of lead and cadmium in wines by graphite furnace atomic absorption spectrometry
    Kim, M
    FOOD ADDITIVES AND CONTAMINANTS, 2004, 21 (02): : 154 - 157