Evaluation and application of bismuth as an internal standard for the determination of lead in wines by simultaneous electrothermal atomic absorption spectrometry

被引:37
|
作者
Fernandes, KG
de Moraes, M
Neto, JAG
Nóbrega, JA
Oliveira, PV
机构
[1] Univ Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil
[2] Univ Fed Sao Carlos, Dept Quim, BR-13560970 Sao Carlos, SP, Brazil
[3] Univ Sao Paulo, Inst Quim, BR-05513970 Sao Paulo, Brazil
关键词
D O I
10.1039/b105309b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the direct determination of Pb in wines by simultaneous multi-element atomic absorption spectrometry (SIMAAS) using a transversely heated graphite atomizer, Zeeman-effect background corrector and internal standardization is proposed. Bismuth was used as an internal standard and Pd(NO3)(2) plus Mg(NO3)(2) as chemical modifier,to stabilize both the analyte and the internal standard. The implementation of two pyrolysis steps avoided any build-up of carbonaceous residues on the graphite platform. All diluted samples (1 + 1 v/v) in 0.2% v/v HNO3 and reference solutions (5.0-50 mug l(-1) Ph in 0.2% v/v HNO3) were spiked with 25 mug l(-1) Bi. For a 20 mul aliquot dispensed into the graphite tube, a good correlation (r = 0.9997) was obtained between the ratio of the analyte signal to the internal standard signal and the analyte concentration of the reference solutions. The electrothermal behaviour of Pb and Bi in red, white and rose wines were compared. In addition, absorbance variations due to changes in experimental conditions, such as atomizer temperature, integration time, injected sample volume, radiation beam intensity, graphite tube surface, dilution and sample composition, were minimized by using Bi as internal standard. Relative standard deviations of measurements based on integrated absorbance varied from 0.1 to 3.4% and from 0.5 to 7.3% (n = 12) with and without internal standard correction, respectively. Good recoveries (91-104%) for Pb spikes were obtained. The characteristic mass was 45 pg Pb and the limit of detection based on integrated absorbance was 0.9 mug l(-1) Pb. Internal standardization increased the lifetime of the tube by 25%. Direct determinations of Pb in wines with and without internal standardization approaches were in agreement at the 95% confidence level. The repeatability and the tube lifetime were improved when using Bi as internal standard. The improvement in accuracy using an internal standard was only observed when the analytical results were affected by errors.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [2] DETERMINATION OF LEAD AND ARSENIC IN WINES BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    BRUNO, SNF
    CAMPOS, RC
    CURTIUS, AJ
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (03) : 341 - 344
  • [3] Bismuth as a general internal standard for lead in atomic absorption spectrometry
    Bechlin, Marcos A.
    Fortunato, Felipe M.
    Ferreira, Edilene C.
    Gomes Neto, Jose A.
    Nobrega, Joaquim A.
    Donati, George L.
    Jones, Bradley T.
    [J]. ANALYTICA CHIMICA ACTA, 2014, 831 : 24 - 30
  • [4] Simultaneous determination of cadmium and lead in wine by electrothermal atomic absorption spectrometry
    Freschi, GPG
    Dakuzaku, CS
    de Moraes, M
    Nóbrega, JA
    Neto, JAG
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (10) : 1987 - 1993
  • [5] Silver as internal standard for simultaneous determination of Cd and Pb in whole blood by electrothermal atomic absorption spectrometry
    Correia, PRM
    Oliveira, PV
    Neto, JAG
    Nóbrega, JA
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (07) : 917 - 922
  • [6] Investigations into the simultaneous determination of bismuth and selenium by 'in atomizer trapping' electrothermal atomic absorption spectrometry
    Murphy, J
    Jones, P
    Schlemmer, G
    Shuttler, IL
    Hill, SJ
    [J]. ANALYTICAL COMMUNICATIONS, 1997, 34 (11): : 359 - 362
  • [7] On-line preconcentration system coupled to electrothermal atomic absorption spectrometry for the simultaneous determination of bismuth, cadmium, and lead in urine
    Sung, YH
    Huang, SD
    [J]. ANALYTICA CHIMICA ACTA, 2003, 495 (1-2) : 165 - 176
  • [8] On the determination of lead in wine by electrothermal atomic absorption spectrometry
    Karadjova, Irina
    Cvetkovic, Julijana
    Stafilov, Trajce
    Arpadjan, Sonja
    [J]. CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2007, 5 (03): : 739 - 747
  • [9] Evaluation of internal standardisation in electrothermal atomic absorption spectrometry
    Radziuk, B
    Romanova, NP
    Thomassen, Y
    [J]. ANALYTICAL COMMUNICATIONS, 1999, 36 (01): : 13 - 16
  • [10] DETERMINATION OF LEAD IN FISH BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    CABRERA, C
    LORENZO, ML
    GALLEGO, C
    LOPEZ, MC
    LILLO, E
    [J]. ANALYTICA CHIMICA ACTA, 1991, 246 (02) : 375 - 378