Preoperative 123I/99mTc-Sestamibi Subtraction SPECT and SPECT/CT in Primary Hyperparathyroidism

被引:88
|
作者
Neumann, Donald R. [1 ]
Obuchowski, Nancy A. [2 ]
DiFilippo, Frank P. [1 ]
机构
[1] Cleveland Clin, Imaging Inst, Dept Nucl Med, Cleveland, OH 44195 USA
[2] Cleveland Clin, Imaging Inst, Dept Diagnost Radiol, Cleveland, OH 44195 USA
关键词
hyperparathyroidism; SPECT; SPECT/CT; hybrid imaging;
D O I
10.2967/jnumed.108.054858
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The trend toward focused surgical parathyroidectomy requires precise preoperative localization of parathyroid lesions in patients with hyperparathyroidism. The purpose of this study was to directly compare the diagnostic accuracy of (99m)Tc-sestamibi/(123)I subtraction SPECT with SPECT/CT for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism. Methods: A total of 61 consecutive surgical patients with primary hyperparathyroidism underwent both (123)I/99mTc-sestamibi subtraction SPECT and SPECT/CT scans preoperatively, using a hybrid SPECT/CT instrument that combined a dual-detector SPECT camera with a 6-slice multicletector spiral CT scanner. Four hours after being given (123)I-sodium iodide orally, each patient received (99m)Tc-sestamibi intravenously, followed immediately by a simultaneous, dual-isotope SPECT scan of the neck and upper chest. Then, without moving the patient, we performed a noncontrast-enhanced CT scan of the same body region. Normalization and subtraction of the (123)I SPECT images from the (99m)Tc SPECT images were performed. The subtraction SPECT and the coregistered fused SPECT/CT studies were interpreted separately, with images scored on a 5-point scale. Surgical and histopathologic findings were used as the standard of comparison. Results: Surgery was successful in 57 patients (solitary parathyroid adenoma in 48 patients, double parathyroid adenomas in 6 patients, and 10 hyperplastic parathyroid glands in 3 patients). The sensitivities of SPECT (50/70 = 71%) and SPECT/CT (49/70 = 70%) were similar (P = 0.779). The specificity of SPECT/CT (26/27 = 96%) was significantly greater than that of SPECT (13/27 = 48%; P = 0.006). The receiver-operating-characteristic area under the curve of SPECT/CT (0.833) was significantly greater than that of SPECT (0.632; P < 0.001). Conclusion: SPECT/CT is significantly more specific than dual-isotope subtraction SPECT for the preoperative identification of parathyroid lesions in patients with primary hyperparathyroidism.
引用
收藏
页码:2012 / 2017
页数:6
相关论文
共 50 条
  • [41] Value of dual-phase 99mTc Sestamibi SPECT/CT in preoperative assessment of patients with primary hyperparathyroidism
    Solar, N.
    Taborska, K.
    Astl, J.
    Libansky, P.
    Smutny, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S360 - S360
  • [42] Dual-phase 99mTc-Sestamibi scintigraphy with neck and thorax SPECT/CT in primary hyperparathyroidism: A single institution experience
    Ciappuccini, R.
    Morera, J.
    Pascal, P.
    Rame, J.
    Heutte, N.
    Aide, N.
    Babin, E.
    Reznik, Y.
    Bardet, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S167 - S167
  • [43] EVALUATION AND RISK STRATIFICATION OF RENAL MASSES WITH 99MTC-SESTAMIBI SPECT/CT
    Sistani, Golmehr
    Bjazevic, Jennifer
    Kassam, Zahra
    Romsa, Jonathan
    Pautler, Stephen
    JOURNAL OF UROLOGY, 2020, 203 : E913 - E913
  • [44] 99mTC-Sestamibi SPECT/CT Imaging for the Risk Stratification of Renal Masses
    Sistani, Golmehr
    Bjazevic, Jennifer
    Zahra, Kassam
    Stephen, Pautler
    Romsa, Jonathan
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [45] 99mTc-sestamibi SPECT/CT for the characterization of renal masses: a pictorial guide
    Campbell, Scott P.
    Tzortzakakis, Antonios
    Javadi, Mehrbod S.
    Karlsson, Mattias
    Solnes, Lilja B.
    Axelsson, Rimma
    Allaf, Mohamad E.
    Gorin, Michael A.
    Rowe, Steven P.
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1084):
  • [46] 99mTc-Sestamibi SPECT/CT and histopathological features of oncocytic renal neoplasia
    Tzortzakakis, Antonios
    Papathomas, Thomas
    Gustafsson, Ove
    Gabrielson, Stefan
    Trpkov, Kiril
    Ekstrom-Ehn, Linnea
    Arvanitis, Alexandros
    Holstensson, Maria
    Karlsson, Mattias
    Kokaraki, Georgia
    Axelsson, Rimma
    SCANDINAVIAN JOURNAL OF UROLOGY, 2022, 56 (5-6) : 375 - 382
  • [47] The value of parathyroid I-123/Tc-99m subtraction SPECT/CT in primary hyperparathyroidism
    Korsten, Alex
    van Os, Karen
    Wille, Jan
    Eland, Ingo
    van Buul, Marie Monique
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [48] Value of Dual-Phase 99mTc-Sestamibi Scintigraphy With Neck and Thoracic SPECT/CT in Secondary Hyperparathyroidism
    Yang, Jigang
    Hao, Ruirui
    Yuan, Leilei
    Li, Chunlin
    Yan, Jue
    Zhen, Lishi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (01) : 180 - 184
  • [49] Is dual-phase SPECT/CT with 99mTc-sestamibi better than single-phase SPECT/CT for lesion localization in patients with hyperparathyroidism?
    Lee, Suk Hyun
    Shin, Eonwoo
    Ha, Sejin
    Oh, Jungsu S.
    Song, Dong Eun
    Ryu, Jin-Sook
    MEDICINE, 2020, 99 (19) : E19989
  • [50] Value of 18F-Choline PET-CT in the assessment of primary hyperparathyroidism comparing with 99mTC-Sestamibi SPECT-CT
    Beheshti, M.
    Imamovic, L.
    Spaun, G.
    Steinmair, M.
    Emmanuel, K.
    Alibegovic, V.
    Pirich, C.
    Langsteger, W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S66 - S66