Hands-free Cursor Control using Intuitive Head Movements and Cheek Muscle Twitches

被引:0
|
作者
Sancheti, Khushal [1 ]
Krishnan, Sridhar K. [1 ]
Suhaas, A. [1 ]
Suresh, P. [1 ]
机构
[1] PES Univ, Dept Elect & Commun Engn, Bengaluru, India
关键词
Tetraplegia; disabilities; DASH; Assistive technologies; HCI; hands-free; mouse; cursor; click; intuitive; head movement; tracking; cheek muscle twitch; Inertial Measurement Unit; accelerometer; magnetometer; flex sensor; bend sensor; PEOPLE; TRACKING; ACCESS; SPEECH;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a proof of concept prototype for a Human-Computer Interface (HCI) device, using which, a person can control a computer cursor solely with head movements and cheek muscle twitches. The prototype is realised as a light-weight wearable headgear that beneficially utilises two different voluntary signals of human head for computer cursor control: 1) intuitive head movement for proportional cursor movement, and 2) cheek muscle twitches for cursor clicks. This potential Assistive Technology (AT) can be immensely helpful for people with tetraplegia and Disabilities of Arm, Shoulder and Hand (DASH). This paper proposes use of accelerometer and magnetometer for head movement tracking, and flex sensors to detect cheek muscle twitches, to achieve a hands-free HCI device for cursor control. In experimental trials, when using this prototype, five novice users took 2.12 times more time on an average as compared to a standard optical computer mouse to move a cursor from one point to another and perform a click.
引用
收藏
页码:0356 / 0361
页数:6
相关论文
共 50 条
  • [41] Forehead sEMG signal based HMI for hands-free control
    Zhang, Yi
    Zhu, Xiang
    Dai, Ling-Ling
    Luo, Yuan
    Journal of China Universities of Posts and Telecommunications, 2014, 21 (03): : 98 - 105
  • [42] Forehead sEMG signal based HMI for hands-free control
    ZHANG Yi
    ZHU Xiang
    DAI Ling-ling
    LUO Yuan
    The Journal of China Universities of Posts and Telecommunications, 2014, (03) : 98 - 105
  • [43] Hands-free telephones -: joint control of echo cancellation and postfiltering
    Hänsler, E
    Schmidt, GU
    SIGNAL PROCESSING, 2000, 80 (11) : 2295 - 2305
  • [44] High-level hands-free control of wheelchair–a review
    Ashok S.
    Journal of Medical Engineering and Technology, 2017, 41 (01): : 46 - 64
  • [45] Mouse Cursor Control System Using Facial Movements
    Tabuse, Masayoshi
    Mizobe, Manase
    Yoshitomi, Yasunari
    Asada, Taro
    PROCEEDINGS OF THE 2020 INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS (ICAROB2020), 2020, : 394 - 397
  • [46] Using hands-free technology in programs for profoundly disabled children
    Eachus, HT
    Junker, AM
    INTERNATIONAL CONFERENCE ON COMPUTING AND INFORMATION TECHNOLOGIES : EXPLORING EMERGING TECHNOLOGIES, 2001, : 111 - 117
  • [47] INTELLIGIBILITY OF ELECTROLARYNX SPEECH USING A NOVEL HANDS-FREE ACTUATOR
    Madden, Brian
    Nolan, Mark
    Burke, Edward
    Condron, James
    Coyle, Eugene
    BIOSIGNALS 2011, 2011, : 265 - 269
  • [48] A hands-free unit with noise reduction by using adaptive beamformer
    Kobayashi, Kazunori
    Haneda, Yoichi
    Furuya, Ken'ichi
    Kataoka, Akitoshi
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 2008, 54 (01) : 116 - 122
  • [49] SUBJECTIVE QUALITY ESTIMATION USING PESQ FOR HANDS-FREE TERMINALS
    Kurihara, Sachiko
    Fukui, Masahiro
    Shimauchi, Suehiro
    Harada, Noboru
    2020 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2020, : 921 - 925
  • [50] Mouthwitch: A Novel Head Mount Type Hands-Free Input Device that Uses the Movement of the Temple to Control a Camera
    Taniguchi, Kazuhiro
    Nishikawa, Atsushi
    SENSORS, 2018, 18 (07)