Membrane fouling in aerobic granular sludge (AGS)-membrane bioreactor (MBR): Effect of AGS size

被引:239
|
作者
Zhang, Wenxiang [1 ,2 ]
Jiang, Feng [2 ]
机构
[1] Guangdong Univ Technol, Inst Environm & Ecol Engn, Sch Environm Sci & Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] South China Normal Univ, Sch Chem & Environm, Guangzhou, Guangdong, Peoples R China
关键词
Aerobic granular sludge (AGS); Membrane fouling control; Membrane bioreactor (MBR); Critical AGS size; Shear stress; WASTE-WATER TREATMENT; PERFORMANCE; GROWTH; MODEL;
D O I
10.1016/j.watres.2018.07.069
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The main goal of the current study was to investigate the membrane fouling mechanism of aerobic granular sludge (AGS) with various AGS sizes. In this regard, AGSs were sieved into 6 levels: 0 similar to 0.5, 0.5 similar to 0.7, 0.7 similar to 1, 1 similar to 1.2, 1.2 similar to 1.7 mm and larger than 1.7 mm, then filtrated by a small dead-end filtration cell. Interestingly, there appeared a critical AGS size (1 similar to 1.2 mm) for membrane fouling. Above 1.2 mm, flux increased and fouling reduced with size, due to the loose cake layer and high permeability caused by larger AGS. Below 1 mm, for smaller AGS, higher flux and lower fouling appeared, because less extra cellular polymeric substance (EPS) formed and adhered onto AGS foulants. In the critical size, membrane fouling was serious to the most extent, on account of the dual role of the compact structure of cake fouling layer and the adhesion of EPS. Moreover, this critical AGS size also possessed the highest cake layer, pore blocking and irreversible fouling, which generally existed in various operational conditions. Besides, the results of SEM, AFM, hydrophilicity and ATR-FTIR also proved that the existence of the maximum membrane fouling at the critical AGS size. This study provides a deep understanding of the membrane fouling mechanisms of AGS in membrane filtration and is beneficial for developing a new membrane fouling mitigation strategy by terms of regulating AGS size. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:445 / 453
页数:9
相关论文
共 50 条
  • [41] Membrane fouling and physical characteristics of sludge in MBR system
    Khongnakorn, W.
    Wisniewski, C.
    DESALINATION AND WATER TREATMENT, 2010, 18 (1-3) : 235 - 238
  • [42] Sludge characteristics and effect of crossflow membrane filtration on membrane fouling in a jet loop membrane bioreactor (JLMBR)
    Farizoglu, Burhanettin
    Keskinler, Bulent
    JOURNAL OF MEMBRANE SCIENCE, 2006, 279 (1-2) : 578 - 587
  • [43] The effect of calcium on the membrane biofouling in the membrane bioreactor (MBR)
    Kim, In S.
    Jang, Namjung
    WATER RESEARCH, 2006, 40 (14) : 2756 - 2764
  • [44] The impact of height/diameter ratio on aerobic granular sludge(AGS) system in domestic sewage
    Li, Dong
    Wang, Ying-Qiao
    Zhang, Jie
    Li, Shuai
    Wang, Yu-Ying
    Zhongguo Huanjing Kexue/China Environmental Science, 2019, 39 (01): : 141 - 148
  • [45] Effective sludge activation in a sequencing batch reactor (SBR) towards aerobic granular sludge (AGS) technology
    Setianingsih, Nanik Indah
    Hadiyanto
    Budihardjo, Mochamad Arief
    Yuliasni, Rustiana
    Vistanty, Hanny
    Budiono
    Sudarno
    Warsito, Budi
    DESALINATION AND WATER TREATMENT, 2024, 320
  • [46] Ultrafiltration of aerobic granular sludge bioreactor effluent: Fouling potentials and properties
    Yang, Zhengjian
    Tran, Quang N.
    Jin, Xue
    JOURNAL OF WATER PROCESS ENGINEERING, 2022, 47
  • [47] Influence of sludge rheological properties on the membrane fouling in submerged membrane bioreactor
    Azami, Hamed
    Sarrafzadeh, Mohammad Hossein
    Mehrnia, Mohammad Reza
    DESALINATION AND WATER TREATMENT, 2011, 34 (1-3) : 117 - 122
  • [48] Influence of activated sludge characteristics on membrane fouling in a hybrid membrane bioreactor
    Wang, Xiaochang C.
    Hu, Yisong S.
    Liu, Qiang
    DESALINATION AND WATER TREATMENT, 2012, 42 (1-3) : 30 - 36
  • [49] Influence of sludge composition on membrane fouling in membrane coupled anaerobic bioreactor
    Wu, Zhi-Chao
    Wang, Zhi-Wei
    Gu, Guo-Wei
    Yu, Guo-Ping
    Zhongguo Huanjing Kexue/China Environmental Science, 2005, 25 (02): : 226 - 230
  • [50] Membrane fouling in thermophilic membrane bioreactor with different sludge retention times
    Ince, Elif
    Ince, Mahir
    Topaloglu, Alikemal
    MEMBRANE WATER TREATMENT, 2018, 9 (05) : 343 - 351