Spectrophotometric determination of nitrate in hypersaline waters after optimization based on the Box-Behnken design

被引:11
|
作者
Valiente, Nicolas [1 ]
Gomez-Alday, Juan J. [1 ]
Jirsa, Franz [2 ,3 ]
机构
[1] UCLM, Inst Reg Dev IDR, Biotechnol & Nat Resources Sect, Campus Univ S-N, Albacete 02071, Spain
[2] Univ Vienna, Inst Inorgan Chem, Waehringer Str 42, A-1090 Vienna, Austria
[3] Univ Johannesburg, Dept Zool, POB 524,Auckland Pk, ZA-2006 Johannesburg, South Africa
关键词
Nitrate analyses; Griess reaction; Hypersaline water; Vanadium chloride; Box-Behnken design; LIQUID-LIQUID MICROEXTRACTION; NITRITE; NITROGEN; REDUCTION; LAKE; EUTROPHICATION; GROUNDWATER; URANIUM; CYCLES; VOLUME;
D O I
10.1016/j.microc.2018.12.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring dissolved nitrate (NO3-) concentrations is essential for conservation efforts in aquatic ecosystems. Spectrophotometric methods are a widely accepted approach for NO3- analysis. They detect NO3- as a colored diazo complex after reduction to nitrite (NO2-) and its consequent reaction with the so-called Griess reagent. This method is commonly used for freshwater and saline water samples, even though it requires applying a heavy metal in powder form (cadmium) or high concentrations of heavy metal salts (vanadium-III), as a reductant. There has been little discussion about applying these methods for hypersaline samples. This study optimizes an existing method for use in high saline conditions based on the Griess reaction. Five factors were studied: incubation temperature, reaction time, concentration of EDTA, concentration of trisodium citrate, and concentration of reductant (VCl3). Optimal conditions were obtained by using the Box-Behnken design and included using VCl3 17.5 mM, trisodium citrate 70 mM, and an incubation temperature of 60 degrees C for 40 min. These conditions provided a linear range from 0.55 mu M to 50 mu M NO3-. The method showed a moderate precision (ranging from 4.3% to 15.4%). The proposed protocol was tested with hypersaline natural samples and showed recovery rates between 92.6% and 100.1%. This protocol for NO3- determination is the first specifically described for hypersaline samples.
引用
收藏
页码:951 / 958
页数:8
相关论文
共 50 条
  • [21] Formulation and optimization of rifampicin microparticles by Box-Behnken statistical design
    Maurya, D. P.
    Sultana, Yasmin
    Aqil, Mohd.
    Ali, A.
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2012, 17 (06) : 687 - 696
  • [22] Design and Statistical Optimization of Pluronic Based Ibuprofen Gels by Box-Behnken Design and Their Physicochemical Characterization
    Harani Avasarala
    D. Sathis Kumar
    Srijit Tripathy
    Sathi Sravani
    Veera Vimala devi
    Shaike Kamaluddin
    Pharmaceutical Chemistry Journal, 2023, 57 : 129 - 137
  • [23] Design and Statistical Optimization of Pluronic Based Ibuprofen Gels by Box-Behnken Design and Their Physicochemical Characterization
    Avasarala, Harani
    Kumar, D. Sathis
    Tripathy, Srijit
    Sravani, Sathi
    Devi, Veera Vimala
    Kamaluddin, Shaike
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2023, 57 (01) : 129 - 137
  • [24] Optimization of squeeze casting process of gearbox cover based on FEM and Box-Behnken design
    Li, Junhong
    Sun, Yu
    Wang, Yu
    Sun, Jue
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2022, 118 (9-10): : 3421 - 3430
  • [25] Optimization of picosecond laser machining parameters for monocrystalline silicon based on Box-Behnken Design
    Li, Zhe
    Huang, Chuanzhen
    Wang, Zhen
    Shi, Zhenyu
    Xu, Longhua
    Huang, Shuiquan
    Qu, Meina
    Xu, Zhengkai
    Zhang, Dijia
    Guo, Baosu
    Liu, Hanlian
    Liu, Dun
    Yao, Peng
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2025, 188
  • [26] Application of Box-Behnken design and desirability function in the optimization of spectrophotometric method for the quantification of WADA banned drug: Acetazolamide
    Rahman, Nafisur
    Sameen, Shahroora
    Kashif, Mohammad
    JOURNAL OF MOLECULAR LIQUIDS, 2019, 274 : 270 - 277
  • [27] Optimization of squeeze casting process of gearbox cover based on FEM and Box-Behnken design
    Junhong Li
    Yu Sun
    Yu Wang
    Jue Sun
    The International Journal of Advanced Manufacturing Technology, 2022, 118 : 3421 - 3430
  • [28] Application of Box-Behnken Design in the Optimization of In Situ Surfactant-Based Solid Phase Extraction Method for Spectrophotometric Determination of Quinoline Yellow in Food and Water Samples
    Hamedpour, Vahid
    Amjadi, Mohammad
    FOOD ANALYTICAL METHODS, 2014, 7 (05) : 1123 - 1129
  • [29] Preparation and optimization of fisetin loaded glycerol based soft nanovesicles by Box-Behnken design
    Moolakkadath, Thasleem
    Aqil, Mohd
    Ahad, Abdul
    Imam, Syed Sarim
    Praveen, Arshiya
    Sultana, Yasmin
    Mujeeb, Mohd
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2020, 578
  • [30] Optimization of pressure swing adsorption for hydrogen purification based on Box-Behnken design method
    Zhang, Nannan
    Benard, Pierre
    Chahine, Richard
    Yang, Tianqi
    Xiao, Jinsheng
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (07) : 5403 - 5417