Comparison of Material Decomposition Methods in Contrast Enhancement Digital Mammography Based on Photon Counting

被引:0
|
作者
Choi, Yu-Na [1 ]
Kim, Hee-Joung [1 ]
Cho, Hyo-Min [1 ]
Lee, Seung-Wan [1 ]
Ryu, Hyun-Ju [1 ]
Lee, Young-Jin [1 ]
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju, South Korea
关键词
X-RAY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Photon counting detector with energy discrimination has made it possible to decompose materials. In this study, we compared two material decomposition methods in CEDM using a Monte Carlo simulation. The K-edge and dual energy imaging methods were used for material decomposition. We designed the cadmium telluride (CdTe) detector based on photon counting using GEANT4 Application for Tomographic Emission (GATE) version 6.0 simulation tools. The CdTe detector was 44.8x44.8 mm(2) and thickness of 1 mm. To verify the material decomposition ability, we designed the phantom with GATE. The phantom was a cylinder of breast equivalent tissue material (ICRV-44) containing iodine inserts at various thicknesses ranging from 0.3 to 1.5 mm. Thicknesses of breast equivalent tissue material was 20, 30, 40, and 50 mm. First, to verify the material decomposition ability of K-edge imaging, we obtained image from 34-44 keY energy window because the K-edge energy of iodine is 33.2 keY. Second, for the dual energy imaging methods, we acquired two images with below and above the iodine K-edge energy using one exposure with energy selective windows. Data for material decomposition algorithm were obtained for various combinations step wedge phantom of breast tissue equivalent materials and iodine. The images from the phantom were used to produce the inverse mapping functions. The ability of material decomposition was investigated in terms of a contrast-to-noise ratio (CNR). According to the results, the CNR with K-edge imaging method was higher than dual energy method. The calculated values of CNR with K-edge imaging method were approximately 1.60 times higher than with dual energy imaging method. Our studies may be used as a basis for future studies on X-ray imaging based on photon counting.
引用
收藏
页码:2855 / 2858
页数:4
相关论文
共 50 条
  • [41] Physical characterization of a scanning photon counting digital mammography system based on Si-strip detectors
    Aslund, Magnus
    Cederstrom, Bjorn
    Lundqvist, Mats
    Danielsson, Mats
    MEDICAL PHYSICS, 2007, 34 (06) : 1918 - 1925
  • [42] Contrast-enhanced spectral mammography based on a photon-counting detector: Quantitative accuracy and radiation dose
    Lee, Seungwan
    Kang, Sooncheol
    Eom, Jisoo
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [43] Experimental study of two material decomposition methods using multi-bin photon counting detectors
    Zimmerman, Kevin C.
    Sidky, Emil Y.
    Schmidt, Taly Gilat
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [44] Assessment of silver sulfide nanoparticles as a contrast agent for spectral photon-counting mammography
    Hsu, Jessica
    Lau, Kristen
    Cormode, David
    Maidment, Andrew
    Cai, Weibo
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [45] Comparison of tomosynthesis methods used with digital mammography
    Suryanarayanan, S
    Karellas, A
    Vedantham, S
    Glick, SJ
    D'Orsi, CJ
    Baker, SP
    Webber, RL
    ACADEMIC RADIOLOGY, 2000, 7 (12) : 1085 - 1097
  • [46] DIGITAL MAMMOGRAPHY - A COMPARISON OF 2 DIGITIZATION METHODS
    KIMMESMITH, C
    BASSETT, LW
    GOLD, RH
    GORMLEY, L
    INVESTIGATIVE RADIOLOGY, 1989, 24 (11) : 869 - 875
  • [47] A multiscale and multi-orientation contrast enhancement method for digital mammography
    Cherifi, Daikha
    Beghdadi, Azeddine
    Belbachir, Ahmed Hafid
    2008 3RD INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS, CONTROL AND SIGNAL PROCESSING, VOLS 1-3, 2008, : 312 - +
  • [48] CT material decomposition with contrast agents: Single or multiple spectral photon-counting CT scans? A simulation study
    Sawall, Stefan
    Baader, Edith
    Trapp, Philip
    Kachelriess, Marc
    MEDICAL PHYSICS, 2025,
  • [49] Image-based Material Decomposition with a General Volume Constraint for Photon-Counting CT
    Li, Zhoubo
    Leng, Shuai
    Yu, Lifeng
    Yu, Zhicong
    McCollough, Cynthia H.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [50] Theoretical comparison and optimization of cadmium telluride and gallium arsenide photon-counting detectors for contrast-enhanced spectral mammography
    Schaeffer, Colin
    Ghammraoui, Bahaa
    Taguchi, Katsuyuki
    Glick, Stephen J.
    JOURNAL OF MEDICAL IMAGING, 2023, 10