Comparison of Material Decomposition Methods in Contrast Enhancement Digital Mammography Based on Photon Counting

被引:0
|
作者
Choi, Yu-Na [1 ]
Kim, Hee-Joung [1 ]
Cho, Hyo-Min [1 ]
Lee, Seung-Wan [1 ]
Ryu, Hyun-Ju [1 ]
Lee, Young-Jin [1 ]
机构
[1] Yonsei Univ, Dept Radiol Sci, Wonju, South Korea
关键词
X-RAY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Photon counting detector with energy discrimination has made it possible to decompose materials. In this study, we compared two material decomposition methods in CEDM using a Monte Carlo simulation. The K-edge and dual energy imaging methods were used for material decomposition. We designed the cadmium telluride (CdTe) detector based on photon counting using GEANT4 Application for Tomographic Emission (GATE) version 6.0 simulation tools. The CdTe detector was 44.8x44.8 mm(2) and thickness of 1 mm. To verify the material decomposition ability, we designed the phantom with GATE. The phantom was a cylinder of breast equivalent tissue material (ICRV-44) containing iodine inserts at various thicknesses ranging from 0.3 to 1.5 mm. Thicknesses of breast equivalent tissue material was 20, 30, 40, and 50 mm. First, to verify the material decomposition ability of K-edge imaging, we obtained image from 34-44 keY energy window because the K-edge energy of iodine is 33.2 keY. Second, for the dual energy imaging methods, we acquired two images with below and above the iodine K-edge energy using one exposure with energy selective windows. Data for material decomposition algorithm were obtained for various combinations step wedge phantom of breast tissue equivalent materials and iodine. The images from the phantom were used to produce the inverse mapping functions. The ability of material decomposition was investigated in terms of a contrast-to-noise ratio (CNR). According to the results, the CNR with K-edge imaging method was higher than dual energy method. The calculated values of CNR with K-edge imaging method were approximately 1.60 times higher than with dual energy imaging method. Our studies may be used as a basis for future studies on X-ray imaging based on photon counting.
引用
收藏
页码:2855 / 2858
页数:4
相关论文
共 50 条
  • [1] Comparison of contrast enhancement methods using photon counting detector in spectral mammography
    Kim, Hyemi
    Park, Su-Jin
    Jo, Byungdu
    Kim, Dohyeon
    Kim, Hee-Joung
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [2] Material Decomposition in Contrast-enhanced Digital Mammography Based on Photon Counting: Monte Carlo Simulation Studies
    Choi, Yu-Na
    Cho, Hyo-Min
    Lee, Seung-Wan
    Ryu, Hyun-Ju
    Lee, Young-Jin
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (01) : 161 - 168
  • [3] Contrast Enhance Digital Mammography Based On Photon-Counting Detector
    Lee, M.
    Lee, D.
    Kim, H.
    Kim, D.
    Kim, H.
    MEDICAL PHYSICS, 2018, 45 (06) : E517 - E517
  • [4] A method for material decomposition in dual-energy contrast enhancement digital mammography
    Kahani, M.
    Kamali-asl, A.
    Ghadiri, H.
    Hashemi, S.
    MEASUREMENT, 2016, 88 : 87 - 95
  • [5] Spectral shaping for photon counting digital mammography
    Aslund, Magnus
    Fredenberg, Erik
    Cederstrom, Bjorn
    Danielsson, Mats
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 1046 - 1049
  • [6] Improvement of three-material decomposition in spectral mammography with a photon-counting detector
    Minjae Lee
    Hyemi Kim
    Journal of the Korean Physical Society, 2022, 81 : 91 - 100
  • [7] Improvement of three-material decomposition in spectral mammography with a photon-counting detector
    Lee, Minjae
    Kim, Hyemi
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 81 (02) : 91 - 100
  • [8] Contrast enhancement by digital equalization in digital mammography
    Huda, W
    Ogden, K
    Scalzetti, E
    Sajewicz, A
    Levin, G
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 234 - 236
  • [9] WAVELETS FOR CONTRAST ENHANCEMENT OF DIGITAL MAMMOGRAPHY
    LAINE, A
    FAN, JA
    YANG, WH
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (05): : 536 - 550
  • [10] Dose Reduction in Contrast-Enhanced Digital Mammography Using a Photon-Counting Detector
    Lee, S.
    Kang, S.
    Eom, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3716 - 3716