Gadolinium(III) ion selective sensor using a new synthesized Schiff's base as a sensing material

被引:65
|
作者
Zamani, Hassan Ali [1 ]
Mohammadhosseini, Majid [2 ]
Haji-Mohammadrezazadeh, Saeed [3 ]
Faridbod, Farnoush [4 ]
Ganjali, Mohammad Reza [4 ,5 ]
Meghdadi, Soraia [6 ]
Davoodnia, Abolghasem [7 ]
机构
[1] Islamic Azad Univ, Dept Appl Chem, Mashhad Branch, Mashhad, Iran
[2] Islamic Azad Univ, Dept Chem, Fac Basic Sci, Shahrood Branch, Shahrood, Iran
[3] Payame Noor Univ, Dept Chem, Ardakan, Iran
[4] Univ Tehran Med Sci, Endocrinol & Metab Res Ctr, Tehran, Iran
[5] Univ Tehran, Ctr Excellence Electrochem, Fac Chem, Tehran, Iran
[6] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
[7] Islamic Azad Univ, Dept Chem, Fac Sci, Mashhad Branch, Mashhad, Iran
关键词
Gadolinium; PVC membrane; Sensor; Potentiometry; Ion selective electrode; PVC-MEMBRANE-ELECTRODE; HEAVY-METAL IONS; SEDIMENT SAMPLES; POTENTIOMETRIC SENSOR; FABRICATION; CONSTRUCTION; SOIL; TRANSITION; COMPLEXES;
D O I
10.1016/j.msec.2012.01.013
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
According to a solution study which showed a selective complexation between N,N'-bis(methylsalicylidene)-2-aminobenzylamine (MSAB) and gadolinium ions, MSAB was used as a sensing element in construction of a gadolinium(III) ion selective electrode. Acetophenon (AP) was used as solvent mediator and sodium tetraphenyl borate (NaTPB) as an anion excluder. The electrode showed a good selectivity towards Gd(III) ions over a wide variety of cations tested. The constructed sensor displayed a Nernstian behavior (19.7 +/- 0.3 mV/decade) in the concentration range of 1.0 x 10(-6) to 1.0 x 10(-2) mol L-1 with detection limit of 5.0 x 10(-7) mol L-1 and a short response time (<10 s). The working pH range of the electrode was 3.5-10.1 and lifetime of the sensor was at least 10 weeks. Analysis of certified reference materials confirmed the accuracy of the proposed sensor. The electrode was successfully applied as an indicator electrode in gadolinium titration with EDTA. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:712 / 717
页数:6
相关论文
共 50 条
  • [31] Highly selective and sensitive chromium(III) membrane sensors based on a new tridentate Schiff's base
    Ganjali, Mohammad Reza
    Norouzi, P.
    Faridbod, F.
    Ghorbani, M.
    Adib, M.
    ANALYTICA CHIMICA ACTA, 2006, 569 (1-2) : 35 - 41
  • [32] Synthesis of a Novel Fluorescent Schiff Base as a Possible Cu(II) Ion Selective Sensor
    Yildirim, Mehmet
    Kaya, Ismet
    JOURNAL OF FLUORESCENCE, 2010, 20 (03) : 771 - 777
  • [33] A chloride ion-selective potentiometric sensor based on a polymeric schiff base complex
    Kumar, KG
    John, KS
    Indira, CJ
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2006, 13 (01) : 13 - 16
  • [34] Synthesis of a Novel Fluorescent Schiff Base as a Possible Cu(II) Ion Selective Sensor
    Mehmet Yıldırım
    İsmet Kaya
    Journal of Fluorescence, 2010, 20 : 771 - 777
  • [35] A Schiff base functioning as a highly selective colorimetric sensor for Cu2+ion
    Kumar, Gujuluva Gangatharan Vinoth
    Arora, Pragya
    Draksharapu, Apparao
    MATERIALS LETTERS, 2024, 371
  • [36] Highly selective and sensitive copper membrane electrode based on a new synthesized Schiff base
    Gholivand, M. B.
    Rahimi-Nasrabadi, M.
    Ganjali, M. R.
    Salavati-Niasari, M.
    TALANTA, 2007, 73 (03) : 553 - 560
  • [37] Novel copper(II)-selective membrane electrode based on a new synthesized Schiff base
    Akhond, Morteza
    Najafi, Mohammad Bagher
    Sharghi, Hashem
    Tashkhourian, Javad
    Naiemi, Hossein
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2007, 54 (02) : 331 - 337
  • [38] Aluminium(III)-selective electrode based on a newly synthesized glyoxal-bis-thiosemicarbazone Schiff base
    Y. Li
    Y. Chai
    R. Yuan
    W. Liang
    L. Zhang
    G. Ye
    Journal of Analytical Chemistry, 2008, 63
  • [39] Aluminium(III)-Selective Electrode Based on a Newly Synthesized Glyoxal-bis-Thiosemicarbazone Schiff Base
    Li, Y.
    Chai, Y.
    Yuan, R.
    Liang, W.
    Zhang, L.
    Ye, G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (11) : 1090 - 1093
  • [40] Manganese (II) selective PVC based membrane sensor using a Schiff base
    Gupta, Vinod K.
    Jain, Ajay K.
    Maheshwari, Gaurav
    TALANTA, 2007, 72 (01) : 49 - 53