Synchrotron radiation response characterization of coplanar grid CZT detectors

被引:18
|
作者
Carini, GA [1 ]
Bolotnikov, AE
Camarda, GS
Wright, GW
De Geronimo, G
Siddons, DP
James, RB
机构
[1] Brookhaven Natl Lab, Nonproliferat & Natl Secur Dept, Upton, NY 11973 USA
[2] Univ Palermo, Dept Elect Engn, I-90128 Palermo, Italy
[3] Brookhaven Natl Lab, Instrumentat Div, Upton, NY 11973 USA
[4] Brookhaven Natl Lab, Natl Synchrotron Light Source, Upton, NY 11973 USA
关键词
D O I
10.1109/TNS.2005.856759
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Commercial 15 x 15 x 7.5 mm(3) coplanar grid CdZnTe detectors were studied on the micron-scale using a collimated high-energy X-ray beam provided by Brookhaven's National Synchrotron Light Source. This powerful tool enables simultaneous studies of detector response uniformity, electronic properties of the material, and effects related to the device's contact pattern and electric field distribution. The availability of a front-end Application Specific Integrated Circuit, developed at Brookhaven's Instrumentation Division, providing low noise amplification of grids and cathode signals, corresponding timing signal and adjustable relative gain, allowed to correlate performance mapping and fluctuations in collected charge. We observed the effect of the strip contacts comprising the coplanar grids on the energy resolution of the coplanar-grid device.
引用
收藏
页码:1941 / 1944
页数:4
相关论文
共 50 条
  • [31] Temperature study of CdZnTe coplanar-grid detectors
    Amman, Mark
    Lee, Julie S.
    Luke, Paul N.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 3035 - 3040
  • [32] Noise reduction in CdZnTe coplanar-grid detectors
    Luke, PN
    Lee, JS
    Amman, M
    Yu, KM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1950 - 1953
  • [33] Noise reduction in CdZnTe coplanar-grid detectors
    Luke, PN
    Lee, JS
    Amman, M
    Yu, KM
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2272 - 2275
  • [34] Measurements on the spectroscopic performance of CdZnTe coplanar grid detectors
    Yucel, H.
    Uyar, E.
    Esen, A. N.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (08) : 1608 - 1615
  • [35] Coplanar grid CdZnTe detectors for space science applications
    Sturm, BW
    He, Z
    Rhodes, E
    Zurbuchen, TH
    Koehn, PL
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS VI, 2004, 5540 : 14 - 21
  • [36] Effects of Surface Processing on the Response of CZT Gamma Detectors: Studies with a Collimated Synchrotron X-Ray Beam
    A. Hossain
    A.E. Bolotnikov
    G.S. Camarda
    Y. Cui
    S. Babalola
    A. Burger
    R.B. James
    Journal of Electronic Materials, 2008, 37 : 1356 - 1361
  • [37] Effects of surface processing on the response of CZT gamma detectors: Studies with a collimated synchrotron X-ray beam
    Hossain, A.
    Bolotnikov, A. E.
    Camarda, G. S.
    Cui, Y.
    Babalola, S.
    Burger, A.
    James, R. B.
    JOURNAL OF ELECTRONIC MATERIALS, 2008, 37 (09) : 1356 - 1361
  • [38] SYNCHROTRON RADIATION DETECTORS FOR TAGGING ELECTRONS
    CRITTENDEN, R
    KRIDER, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 276 (03): : 643 - 646
  • [39] ENERGY DISPERSIVE DETECTORS FOR SYNCHROTRON RADIATION
    WORGAN, JS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 201 (01): : 85 - 91
  • [40] Performance of pixelated CZT detectors as a function of pixel and steering grid layout
    Beilicke, M.
    DeGeronimo, G.
    Dowkontt, P.
    Garson, A.
    Guo, Q.
    Lee, K.
    Martin, J.
    Krawczynski, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 708 : 88 - 100