Pulmonary autograft replacement of the bicuspid aortic valve: a successful surgical option for young adults

被引:8
|
作者
Santini, F [1 ]
Gatti, G [1 ]
Prioli, A [1 ]
Mazzucco, A [1 ]
机构
[1] Univ Verona, Sch Med, Div Cardiac Surg & Cardiol, I-37100 Verona, Italy
关键词
pulmonary autograft; bicuspid aortic valve; aortic root replacement; left ventricular hypertrophy;
D O I
10.1016/S0167-5273(99)00119-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A severely dysfunctioning congenitally bicuspid aortic valve may require surgical treatment within the fourth decade of life. Among conventional options, the pulmonary autograft (PA) offers many theoretical advantages particularly for young patients, including potential for growth, hemodynamic performance. no need for anticoagulants and freedom from endocarditis. However the operation is more complex and longer, may interfere with coronary and right ventricular anatomy and function and may expose the patient to the downside of two valves at risk. Aim of this retrospective study was to evaluate the mid-term results achieved with the PA performed in adolescents and young adults with a bicuspid aortic valve. Between July 94 and June 98, 26 patients, 22 males and four females, with a mean age of 24+/-10 years (range, 11 to 38), underwent bicuspid aortic valve replacement with a pulmonary autograft (stenosis 2-8%; insufficiency 13-50%; combined 11-42%). Eight patients (31%) were in NYHA FC I, 17 (65%) in II, and 1 (4%) in III. Mean preoperative ejection fraction was 67+/-7%. Three patients (11.5%) had a past medical history of endocarditis (healed in all) and in two the PA was a re-do procedure. The PA was inserted as a subcoronary implant in one case (4%) and utilized as a root in the remaining 25 (96%). The right ventricular outflow tract was reconstructed with a cryopreserved pulmonary homograft conduit in all cases. Mean cardiopulmonary bypass and aortic crossclamp times were 204+/-50 min (range, 174 to 300) and 157+/-35 min (range, 133 to 193) respectively, No early or late deaths had occurred at a mean follow-up of 22.5 months (range, 5 to 47.5). The first patient in the series (4%) was reexplored for bleeding and needed transfusions. The subsequent routine use medical and surgical strategies resulted in no further need for postoperative reexploration.: and successful containment of total postoperative blood loss (<350 ml/m2BSA). 2-D Echo evaluation of neo-aortic valve competence at 6 months, revealed no evidence of aortic valve regurgitation in 17 (65%), trivial regurgitation in seven (27%), mild in one (4%)and mild-to-moderate in one (4%). The latter patient (subcoronary implant PA) required reoperation. At six months, the mean degree of regression of left ventricular mass compared to pre-operative data, was 36% (333+/-94 to 212+/-60 gr, p<0.05). All patients are asymptomatic, in NYHA FC I, and enjoy normal social interaction. In conclusion, PA root implantation can be offered as a low-risk alternative to conventional prosthetic aortic valve replacement to adolescents and young adults with a bicuspid aortic valve. The routine achievement of blood loss containment has minimized the risk of transfusion thus contributing to expand the indication in young patients. Continued patients evaluation particularly with regard to evidence of neo-aortic valve degeneration, root dilatation and homograft dysfunction in the long term is warranted. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 50 条
  • [21] Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Bicuspid Aortic Valve Stenosis
    Mentias, Amgad
    Sarrazin, Mary Vaughan
    Desai, Milind Y.
    Saad, Marwan
    Horwitz, Phillip A.
    Kapadia, Samir
    Girotra, Saket
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (19) : 2518 - 2519
  • [22] Aortic root replacement with the pulmonary autograft:: An invariably competent aortic valve?
    Dossche, KM
    de la Riviére, AB
    Morshuis, WJ
    Schepens, MAAM
    Ernst, SM
    van den Brand, JJ
    ANNALS OF THORACIC SURGERY, 1999, 68 (04): : 1302 - 1307
  • [23] Successful Transfemoral Aortic Valve Replacement in a Bicuspid Aortic Stenotic Valve: Requirements for a Safe Implant
    Maluenda, Gabriel
    Araya, Mario
    Ibanez-Arenas, Rodrigo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (06) : E826 - E830
  • [24] Valve-sparing aortic root replacement in bicuspid aortic valves:: A reasonable option?
    Aicher, D
    Langer, F
    Kissinger, A
    Lausberg, H
    Fries, R
    Schäfers, HJ
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (05): : 662 - 668
  • [25] Aneurysms complicating pulmonary autograft procedure for aortic valve replacement
    Shahid, MS
    Al-Halees, Z
    Khan, SM
    Pieters, FAA
    ANNALS OF THORACIC SURGERY, 1999, 68 (05): : 1842 - 1843
  • [26] REPLACEMENT OF THE AORTIC-VALVE WITH A PULMONARY AUTOGRAFT - THE SWITCH OPERATION
    ROSS, D
    ANNALS OF THORACIC SURGERY, 1991, 52 (06): : 1346 - 1350
  • [27] PULMONARY AUTOGRAFT REPLACEMENT OF THE AORTIC-VALVE IN THE POTENTIAL PARENT
    ELKINS, RC
    KNOTTCRAIG, CJ
    RAZOOK, JD
    WARD, KE
    OVERHOLT, ED
    LANE, MM
    JOURNAL OF CARDIAC SURGERY, 1994, 9 (02) : 198 - 203
  • [28] REPLACEMENT OF THE AORTIC-VALVE OR ROOT WITH A PULMONARY AUTOGRAFT IN CHILDREN
    GEROSA, G
    MCKAY, R
    ROSS, DN
    ANNALS OF THORACIC SURGERY, 1991, 51 (03): : 424 - 429
  • [29] PULMONARY AUTOGRAFT REPLACEMENT OF THE AORTIC-VALVE - AN EVOLUTION OF TECHNIQUE
    ELKINS, RC
    SANTANGELO, K
    STELZER, P
    RANDOLPH, JD
    KNOTTCRAIG, CJ
    JOURNAL OF CARDIAC SURGERY, 1992, 7 (02) : 108 - 116
  • [30] LATE ASSESSMENT OF PULMONARY AUTOGRAFT REPLACEMENT FOR AORTIC VALVE DISEASE
    ROSS, D
    SACHS, RG
    SOMERVIL.J
    CIRCULATION, 1971, 44 (04) : 68 - &