Dry laser cleaning threshold fluence - How can it be measured accurately?

被引:0
|
作者
Fernandes, A [1 ]
Kane, D [1 ]
机构
[1] Macquarie Univ, Dept Phys, Div Informat & Commun Sci, Sydney, NSW 2109, Australia
关键词
laser cleaning; laser cleaning threshold fluence; particle removal;
D O I
10.1117/12.456882
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Dry/damp laser cleaning studies are reported that used a XeCl excimer laser to remove alumina particles from glass. These have compared the laser cleaning of samples with medium and low particle densities. Earlier work at Macquarie University used an UV-copper vapour laser (wavelength 255 nm, pulse length 35ns) to investigate single pulse, dry/damp laser cleaning of alumina particles from microscope slides and fused silica surfaces. Medium densities of particles were used. A threshold fluence for dry laser cleaning of 90mJ/cm(2) was measured. Subsequent work using a XeCl excimer laser (wavelength 308 nm, pulse length 8 ns) is reported. The threshold fluence for single pulse laser cleaning of medium density particles increases by a factor of similar to4 at this longer wavelength. Using a sample preparation technique involving laser ablation to prepare lower particle density samples, with reduced particle agglomeration, the results appear qualitatively and quantitatively different than for samples with a medium particle density on the surface. However, careful analysis shows that the dry laser cleaning threshold is the same in each case. This supports the use of the medium particle densities as an experimentally reliable method of determining the laser cleaning threshold fluence.
引用
收藏
页码:290 / 295
页数:2
相关论文
共 50 条
  • [31] Dynamics of particle ejection in dry laser cleaning
    Grojo, David
    Cros, Alain
    Delaporte, Philippe
    Sentis, Marc
    HIGH-POWER LASER ABLATION VI, PTS 1 AND 2, 2006, 6261
  • [32] Dry laser cleaning of mechanically thin films
    Bloisi, F
    Barone, AC
    Vicari, L
    APPLIED SURFACE SCIENCE, 2004, 238 (1-4) : 121 - 124
  • [33] HOW ACCURATELY CAN BLACKBODIES BE CALIBRATED WITH THERMOCOUPLES
    FECTEAU, L
    MARSHALL, GL
    REED, FA
    SEELEY, FB
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1969, 59 (11) : 1536 - &
  • [34] HOW ACCURATELY CAN SEA SCALLOPS BE AGED?
    Roman, Sally
    Rudders, David
    Clark, Kaitlyn
    Southworth, Melissa
    Mann, Roger
    JOURNAL OF SHELLFISH RESEARCH, 2023, 42 : 141 - 141
  • [35] How accurately can mobile calls be placed?
    Bauldreay, J
    IEE REVIEW, 2002, 48 (03): : 22 - 22
  • [36] HOW ACCURATELY CAN THE DEUTERON RADIUS BE DETERMINED
    ERICSON, TEO
    MAHALANABIS, J
    ZEITSCHRIFT FUR PHYSIK A-HADRONS AND NUCLEI, 1985, 322 (02): : 237 - 239
  • [37] Comparison of wet and dry laser cleaning of artworks
    Sarzynski, A.
    Jach, K.
    Marczak, J.
    LASERS IN THE CONSERVATION OF ARTWORKS, PROCEEDINGS, 2007, 116 : 161 - 167
  • [38] PULP CLEANING - HOW CAN IT BE CONTROLLED
    LUNDQVIST, SO
    KEMISK TIDSKRIFT, 1983, 95 (09): : A34 - &
  • [39] HOW CAN PERFORMANCE BE MEASURED
    DOWD, JS
    QUALITY PROGRESS, 1992, 25 (10) : 6 - &
  • [40] FRUSTRATION - HOW IT CAN BE MEASURED
    KOBE, S
    KLOTZ, T
    PHYSICAL REVIEW E, 1995, 52 (05): : 5660 - 5663