Development and validation of a highly sensitive gas chromatographic-mass spectrometric screening method for the simultaneous determination of nanogram levels of fentanyl, sufentanil and alfentanil in air and surface contamination wipes

被引:22
|
作者
Van Nimmen, NFJ [1 ]
Veulemans, HAF [1 ]
机构
[1] Katholieke Univ Leuven, Lab Occupat Hyg & Toxicol, Dept Occupat Environm & Insurance Med, B-3000 Louvain, Belgium
关键词
validation; air analysis; surface contamination; fentanyl; sufentanil; alfentanil; opioids;
D O I
10.1016/j.chroma.2004.02.074
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive gas chromatographic-mass spectrometric (GC-MS) analytical method for the determination of the opioid narcotics fentanyl, alfentanil, and sufentanil in industrial hygiene personal air samples and surface contamination wipes was developed and comprehensively validated. Sample preparation involved a single step extraction of the samples with methanol, fortified with a fixed amount of the penta-deuterated analogues of the opioid narcotics as internal standard. The GC-MS analytical procedure using selected ion monitoring (SIM) was shown to be highly selective. Linearity was shown for levels of extracted wipe and air samples corresponding to at least 0.1-2 times their surface contamination limit (SCL) and accordingly to 0.1-2 times their time weighted average occupational exposure limit (OEL-TWA) based on a full shift 9601 air sample. Extraction recoveries were determined for spiked air samples and surface wipes and were found to be quantitative for both sampling media in the entire range studied. The air sampling method's limit of detection (LOD) was determined to be 0.4 ng per sample for fentanyl and sufentanil and 1.6 ng per sample for alfentanil, corresponding to less than 1 % of their individual OEL for a full shift air sample (9601). The limit of quantification (LOQ) was found to be 1.4, 1.2, and 5.0 ng per filter for fentanyl, sufentanil, and alfentanil, respectively. The wipe sampling method had LODs of 4 ng per wipe for fentanyl and sufentanil and 16 ng per wipe for alfentanil and LOQs of respectively, 14, 12, and 50 ng per wipe. The analytical intra-assay precision of the air sampling and wipe sampling method, defined as the coefficient of variation on the analytical result of six replicate spiked media was below 10 and 5%, respectively, for all opioids at all spike levels. Accuracy expressed as relative error was determined to be below 10%, except for alfentanil at the lowest spike level (-13.1%). The stability of the opioids during simulated air sampling was investigated. For fentanyl and sufentanil a quantitative recovery was observed at all spike levels, while for alfentanil recoveries ranged from 60.3 to 85.4%. When spiked air samples were stored at ambient temperature and at -15 degreesC quantitative recovery was found for fentanyl and sufentanil after 7 and 14 days. For alfentanil a slight loss seemed to occur upon storage during 7 days, being more explicit after 14 days. Ambient storage of spiked wipes seemed to lead to significant losses of all opioids studied, yielding recoveries of 37.7-88.3%. Upon storage of similar wipes at -15 degreesC a significantly higher recovery was found ranging from 77.3 to 88.3%. The developed analytical and sampling procedures have been recently applied in an explorative field study of which the results of surface contamination wipe sampling are presented in this paper. To our knowledge, this is the first study addressing the development and validation of analytical procedures for the assessment of external occupational exposure to potent opioid narcotics. (C) 2004 Elsevier B.V All rights reserved.
引用
收藏
页码:249 / 259
页数:11
相关论文
共 31 条
  • [21] Gas Chromatographic-Mass Spectrometric Method for the Simultaneous Determination of Resveratrol Isomers and 2,4,6-Trihydroxyphenanthrene in Red Wines Exposed to UV-Light
    Francioso, Antonio
    Lastovickova, Lenka
    Mosca, Luciana
    Boffi, Alberto
    Bonamore, Alessandra
    Macone, Alberto
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2019, 67 (42) : 11752 - 11757
  • [22] Development of a screening method to determine the pattern of fermentation metabolites in faecal samples using on-line purge-and-trap gas chromatographic-mass spectrometric analysis
    De Preter, Vicky
    Van Staeyen, Greet
    Esser, Diederik
    Rutgeerts, Paul
    Verbeke, Kristin
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (09) : 1476 - 1483
  • [23] Fast gas chromatographic/mass spectrometric determination of diuretics and masking agents in human urine -: Development and validation of a productive screening protocol for antidoping analysis
    Morra, V.
    Davit, P.
    Capra, R.
    Vincenti, M.
    Di Stilo, A.
    Botre, F.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1135 (02) : 219 - 229
  • [24] HIGHLY SENSITIVE AND SPECIFIC GAS-CHROMATOGRAPHIC TANDEM MASS-SPECTROMETRIC METHOD FOR THE DETERMINATION OF TRACE AMOUNTS OF ANTIPYRINE METABOLITES IN BIOLOGICAL-MATERIAL
    ENGEL, G
    HOFMANN, U
    EICHELBAUM, M
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 666 (01): : 111 - 116
  • [25] Optimization and Validation of a Method Based on QuEChERS Extraction and Gas Chromatographic-Mass Spectrometric Analysis for the Determination of Polycyclic Aromatic Hydrocarbons and Polychlorinated Biphenyls in Olive Fruits Irrigated with Treated Wastewaters
    Bruzzoniti, Maria Concetta
    Rivoira, Luca
    Castiglioni, Michele
    Cagno, Enrico
    Kettab, Ahmed
    Fibbi, Donatella
    Del Bubba, Massimo
    SEPARATIONS, 2022, 9 (03)
  • [26] Development and validation of a sensitive thermal desorption–gas chromatography–mass spectrometry (TD-GC-MS) method for the determination of phosgene in air samples
    Y. Juillet
    C. Dubois
    F. Bintein
    J. Dissard
    A. Bossée
    Analytical and Bioanalytical Chemistry, 2014, 406 : 5137 - 5145
  • [27] A new high-performance liquid chromatographic/electrospray ionization tandem mass spectrometric method for the simultaneous determination of cyclophosphamide, methotrexate and 5-fluorouracil as markers of surface contamination for occupational exposure monitoring
    Sabatini, L
    Barbieri, A
    Tosi, M
    Violante, FS
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (05): : 669 - 674
  • [28] Development and validation of an ultra-high performance liquid chromatographic high resolution Q-Orbitrap mass spectrometric method for the simultaneous determination of steroidal endocrine disrupting compounds in aquatic matrices
    Huysman, Steve
    Van Meulebroek, Lieven
    Vanryckeghem, Francis
    Van Langenhove, Herman
    Demeestere, Kristof
    Vanhaecke, Lynn
    ANALYTICA CHIMICA ACTA, 2017, 984 : 140 - 150
  • [29] Development and validation of a sensitive thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) method for the determination of phosgene in air samples
    Juillet, Y.
    Dubois, C.
    Bintein, F.
    Dissard, J.
    Bossee, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (21) : 5137 - 5145
  • [30] Development of a solventless stir bar sorptive extraction/thermal desorption large volume injection capillary gas chromatographic-mass spectrometric method for ultra-trace determination of pyrethroids pesticides in river and tap water samples
    Sargazi, Mona
    Bucking, Mark
    Kaykhaii, Massoud
    OPEN CHEMISTRY, 2020, 18 (01): : 1339 - 1348