Development and validation of a highly sensitive gas chromatographic-mass spectrometric screening method for the simultaneous determination of nanogram levels of fentanyl, sufentanil and alfentanil in air and surface contamination wipes

被引:22
|
作者
Van Nimmen, NFJ [1 ]
Veulemans, HAF [1 ]
机构
[1] Katholieke Univ Leuven, Lab Occupat Hyg & Toxicol, Dept Occupat Environm & Insurance Med, B-3000 Louvain, Belgium
关键词
validation; air analysis; surface contamination; fentanyl; sufentanil; alfentanil; opioids;
D O I
10.1016/j.chroma.2004.02.074
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly sensitive gas chromatographic-mass spectrometric (GC-MS) analytical method for the determination of the opioid narcotics fentanyl, alfentanil, and sufentanil in industrial hygiene personal air samples and surface contamination wipes was developed and comprehensively validated. Sample preparation involved a single step extraction of the samples with methanol, fortified with a fixed amount of the penta-deuterated analogues of the opioid narcotics as internal standard. The GC-MS analytical procedure using selected ion monitoring (SIM) was shown to be highly selective. Linearity was shown for levels of extracted wipe and air samples corresponding to at least 0.1-2 times their surface contamination limit (SCL) and accordingly to 0.1-2 times their time weighted average occupational exposure limit (OEL-TWA) based on a full shift 9601 air sample. Extraction recoveries were determined for spiked air samples and surface wipes and were found to be quantitative for both sampling media in the entire range studied. The air sampling method's limit of detection (LOD) was determined to be 0.4 ng per sample for fentanyl and sufentanil and 1.6 ng per sample for alfentanil, corresponding to less than 1 % of their individual OEL for a full shift air sample (9601). The limit of quantification (LOQ) was found to be 1.4, 1.2, and 5.0 ng per filter for fentanyl, sufentanil, and alfentanil, respectively. The wipe sampling method had LODs of 4 ng per wipe for fentanyl and sufentanil and 16 ng per wipe for alfentanil and LOQs of respectively, 14, 12, and 50 ng per wipe. The analytical intra-assay precision of the air sampling and wipe sampling method, defined as the coefficient of variation on the analytical result of six replicate spiked media was below 10 and 5%, respectively, for all opioids at all spike levels. Accuracy expressed as relative error was determined to be below 10%, except for alfentanil at the lowest spike level (-13.1%). The stability of the opioids during simulated air sampling was investigated. For fentanyl and sufentanil a quantitative recovery was observed at all spike levels, while for alfentanil recoveries ranged from 60.3 to 85.4%. When spiked air samples were stored at ambient temperature and at -15 degreesC quantitative recovery was found for fentanyl and sufentanil after 7 and 14 days. For alfentanil a slight loss seemed to occur upon storage during 7 days, being more explicit after 14 days. Ambient storage of spiked wipes seemed to lead to significant losses of all opioids studied, yielding recoveries of 37.7-88.3%. Upon storage of similar wipes at -15 degreesC a significantly higher recovery was found ranging from 77.3 to 88.3%. The developed analytical and sampling procedures have been recently applied in an explorative field study of which the results of surface contamination wipe sampling are presented in this paper. To our knowledge, this is the first study addressing the development and validation of analytical procedures for the assessment of external occupational exposure to potent opioid narcotics. (C) 2004 Elsevier B.V All rights reserved.
引用
收藏
页码:249 / 259
页数:11
相关论文
共 31 条
  • [1] Highly sensitive gas chromatographic-mass spectrometric screening method for the determination of picogram levels of fentanyl, sufentanil and alfentanil and their major metabolites in urine of opioid exposed workers
    Van Nimmen, NFJ
    Poels, KLC
    Veulemans, HAF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (02): : 375 - 387
  • [2] Development of a gas chromatographic mass spectrometric drug screening method for the N-dealkylated metabolites of fentanyl, sufentanil, and alfentanil
    Valaer, AK
    Huber, T
    Andurkar, SV
    Clark, CR
    DeRuiter, J
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1997, 35 (10) : 461 - 466
  • [3] Validation of a sensitive gas chromatographic-mass spectrometric method for the simultaneous determination of β-elemene and β-elemenal in human plasma
    Chen, Zhihang
    Song, Yanxia
    Che, Jinjing
    Liu, Xiaolei
    Ning, Yu
    Shan, Chengqi
    Hou, Yunan
    Liu, Yunlong
    Miao, Xiaohong
    Cheng, Yuanguo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (04): : 408 - 414
  • [4] Development and validation of a gas chromatographic-mass spectrometric method for quantitative determination of perphenazine in rabbit plasma after sublingual administration
    Turunen, Elina
    Lehtonen, Marko
    Jarvinen, Tomi
    Jarho, Pekka
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 872 (1-2): : 51 - 57
  • [5] Sensitive gas chromatographic-mass spectrometric method for the determination of gacyclidine in rat plasma and spinal cord dialyzates
    Hoizey, G
    Lamiable, D
    Dukic, S
    Millart, H
    d'Arbigny, P
    Vistelle, R
    ANALYST, 1999, 124 (12) : 1761 - 1764
  • [6] Validation of a simple gas chromatographic-mass spectrometric method for the determination of gamma-butyrolactone in human plasma
    Fukui, Y
    Matsusima, E
    Muramoto, K
    Nagai, N
    Ohama, K
    Yamashita, K
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (01): : 73 - 80
  • [7] A sensitive liquid chromatographic-mass spectrometric method for simultaneous determination of dehydroevodiamine and limonin from Evodia rutaecarpa in rat plasma
    Zhao, Juanjuan
    Han, Xiao
    Zhao, Xu
    Wang, Chao
    Li, Qing
    Chen, Xiaohui
    Bi, Kaishun
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (01) : 289 - 296
  • [8] Sensitive gas chromatographic-mass spectrometric (GC-MS) method for the determination of bisphenol A in rice-prepared dishes
    Zafra-Gomez, A.
    Morales, J. C.
    Ballesteros, O.
    Navalon, A.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (08): : 1209 - 1216
  • [9] Sensitive gas chromatographic-mass spectrometric method for the determination of phthalate esters, alkylphenols, bisphenol A and their chlorinated derivatives in wastewater samples
    Ballesteros, Oscar
    Zafra, Alberto
    Navalon, Alberto
    Vilchez, Jose Luis
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1121 (02) : 154 - 162
  • [10] Highly sensitive gas chromatographic mass spectrometric method for morphine determination in plasma that is suitable for pharmacokinetic studies
    Fryirs, B
    Dawson, M
    Mather, LE
    JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (01): : 51 - 57