A Ratiometric Fluorescent Probe for Cysteine and Homocysteine Displaying a Large Emission Shift

被引:297
|
作者
Lin, Weiying [1 ]
Long, Lingliang [1 ]
Yuan, Lin [1 ]
Cao, Zengmei [1 ]
Chen, Bingbing [1 ]
Tan, Wen [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
基金
美国国家科学基金会;
关键词
D O I
10.1021/ol802436j
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
4-(1H-phenanthro[9,10-d]imidazol-2-yl)benzaldehyde 1 was rationally designed as a novel ratiometric fluorescent probe for cysteine and homocysteine. Upon addition of cysteine or homocysteine, notably, the probe displayed a very large (125 nm) hypsochromic shift in emission due to switching off intramolecular charge transfer. This large emission wavelength shift may allow probe 1 to be employed for quantitatively detecting Cys/Hcy.
引用
收藏
页码:5577 / 5580
页数:4
相关论文
共 50 条
  • [31] A colorimetric and ratiometric fluorescent probe with a large stokes shift for detection of hydrogen sulfide
    Xiang, Kaiqiang
    Liu, Yunchang
    Li, Changjiang
    Tian, Baozhu
    Tong, Tianzhong
    Zhang, Jinlong
    [J]. DYES AND PIGMENTS, 2015, 123 : 78 - 84
  • [32] A ratiometric fluorescence method for the detection of diquat by a large Stokes shift fluorescent probe
    Tang, Zichen
    Lv, Shengchen
    Liu, Donghui
    Liu, Xueke
    Zhou, Zhiqiang
    Wang, Peng
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 323
  • [33] A novel fluorescent probe with red emission and a large Stokes shift for selective imaging of endogenous cysteine in living cells
    Chen, Dugang
    Long, Zi
    Dang, Yecheng
    Chen, Li
    [J]. ANALYST, 2018, 143 (23) : 5779 - 5784
  • [34] A Novel AIE Plus ESIPT Fluorescent Probe with a Large Stokes Shift for Cysteine and Homocysteine: Application in Cell Imaging and Portable Kit
    Song, Haohan
    Zhou, Yanmei
    Qu, Haonan
    Xu, Chenggong
    Wang, Xiao
    Liu, Xiaoqiang
    Zhang, Qingyou
    Peng, Xiaojun
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (44) : 15216 - 15223
  • [35] Detection of organic amines using a ratiometric chromophoric fluorescent probe with a significant emission shift
    Wu, Dan
    Liu, Yi
    Zheng, Fei
    Rong, Shi-Qi
    Yang, Tao
    Zhao, Yan-Kun
    Yang, Rui-Wu
    Zou, Ping
    Wang, Guang-Tu
    [J]. JOURNAL OF CHEMICAL RESEARCH, 2020, 44 (7-8) : 475 - 481
  • [36] Colorimetric and ratiometric fluorescent probe for hydrogen sulfide using a coumarin-pyronine FRET dyad with a large emission shift
    He, Longwei
    Yang, Xueling
    Liu, Yong
    Lin, Weiying
    [J]. ANALYTICAL METHODS, 2016, 8 (45) : 8022 - 8027
  • [37] A novel highly selective ratiometric fluorescent probe with large emission shift for detecting mercury ions in living cells and zebrafish
    Yu, Yamin
    Liu, Caiyun
    Tian, Bin
    Cai, Xinyu
    Zhu, Hanchuang
    Jia, Pan
    Li, Zilu
    Zhang, Xue
    Sheng, Wenlong
    Zhu, Baocun
    [J]. DYES AND PIGMENTS, 2020, 177
  • [38] Probing drug-mediated fluctuations of HClO levels in the endoplasmic reticulum by a ratiometric fluorescent probe with a large emission shift
    Liu, Du
    Yue, Xiuxiu
    Zhang, Hankun
    Li, Ke
    Yang, Zhanhong
    Wang, Benhua
    Song, Xiangzhi
    [J]. DYES AND PIGMENTS, 2023, 215
  • [39] A ratiometric fluorescent probe for specific detection of cysteine over homocysteine and glutathione based on the drastic distinction in the kinetic profiles
    Yuan, Lin
    Lin, Weiying
    Yang, Yueting
    [J]. CHEMICAL COMMUNICATIONS, 2011, 47 (22) : 6275 - 6277
  • [40] A large Stokes shift and emission shift ratiometric mitochondria-targeted fluorescent probe for sensing HClO with an ESIPT-ICT integrated platform
    Shen, Youming
    Jin, Junling
    Chen, Yuandao
    Tang, Yucai
    [J]. MICROCHEMICAL JOURNAL, 2023, 195