Bond behavior of high strength concrete under reversed pull-out cyclic loading

被引:40
|
作者
Alavi-Fard, M [1 ]
Marzouk, H [1 ]
机构
[1] Mem Univ Newfoundland, Fac Engn & Appl Sci, St Johns, NF A1B 3X5, Canada
关键词
bond; high strength; cyclic loading; bar spacing; loading rate; failure mechanism;
D O I
10.1139/L01-088
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Structures located in seismic zones require significant ductility. It is necessary to examine the bond slip characteristics of high strength concrete under cyclic loading. The cyclic bond of high strength concrete is investigated under different parameters, including load history, confining reinforcement, bar diameter, concrete strength, and the rate of pull out. The bond strength, cracking, and deformation are highly dependent on the bond slip behavior between the rebar and the concrete under cyclic loading. The results of cyclic testing indicate that an increase in cyclic displacement will lead to more severe bond damage. The slope of the bond stress - displacement curve can describe the influence of the rate of loading on the bond strength in a cyclic test. Specimens with steel confinement sustained a greater number of cycles than the specimens without steel confinement. It has been found that the maximum bond strength increases with an increase in concrete strength. Cyclic loading does not affect the bond strength of high strength concrete as long as the cyclic slip is less than the maximum slip for monotonic loading. The behavior of high strength concrete under a cyclic load is slightly different from that of normal strength concrete.
引用
收藏
页码:191 / 200
页数:10
相关论文
共 50 条
  • [31] Experimental behavior of circular concrete columns under reversed cyclic loading
    Hindi, Riyadh
    Turechek, Wesley
    CONSTRUCTION AND BUILDING MATERIALS, 2008, 22 (04) : 684 - 693
  • [32] Alkali resistant glass fiber reinforced concrete: Pull-out investigation of interphase behavior under quasi-static and high rate loading
    Scheffler, Christina
    Zhandarov, Serge
    Mäder, Edith
    Cement and Concrete Composites, 2017, 84 : 19 - 27
  • [33] Acoustic emission monitoring for bond integrity evaluation of reinforced concrete under pull-out tests
    Abouhussien, Ahmed A.
    Hassan, Assem A. A.
    ADVANCES IN STRUCTURAL ENGINEERING, 2017, 20 (09) : 1390 - 1405
  • [34] Alkali resistant glass fiber reinforced concrete: Pull-out investigation of interphase behavior under quasi-static and high rate loading
    Scheffler, Christina
    Zhandarov, Serge
    Maeder, Edith
    CEMENT & CONCRETE COMPOSITES, 2017, 84 : 19 - 27
  • [35] Bond strength determination between coconut shell aggregate concrete and steel reinforcement by pull-out test
    Nadir Y.
    Sujatha A.
    Asian Journal of Civil Engineering, 2018, 19 (6) : 713 - 723
  • [36] Regression analysis of the tensile bond pull-out post-anchored method to check concrete strength
    Cui, Shiqi
    Wang, Jinshan
    Pei, Zhaozhen
    Lv, Hongdi
    ENGINEERING STRUCTURAL INTEGRITY: RESEARCH, DEVELOPMENT AND APPLICATION, VOLS 1 AND 2, 2007, : 1434 - +
  • [37] Bond behavior of flexible braided AFRP tendons in high-performance concrete based on pull-out and beam tests
    Xue, Weichen
    Li, Jia
    Wang, Yuan
    JOURNAL OF BUILDING ENGINEERING, 2023, 80
  • [38] Failure of composite sandwich joints under pull-out loading
    Park, Yong-Bin
    Yang, Hyeon-Jeong
    Kweon, Jin-Hwe
    Choi, Jin-Ho
    Cho, Hyun-Il
    COMPOSITES RESEARCH, 2011, 24 (01): : 17 - 23
  • [39] Bond and splitting in reinforced concrete: test results on bar pull-out
    Gambarova, PG
    Rosati, G
    MATERIALS AND STRUCTURES, 1996, 29 (189) : 267 - 276
  • [40] Behavior of High-Performance Concrete Shear Walls with Openings under Reversed Cyclic Loading
    Bhanu, Kannan C.
    Ganesan, N.
    Indira, P., V
    ACI STRUCTURAL JOURNAL, 2022, 119 (01) : 227 - +