Impaction allografting with cement for revision of the femoral component - A minimum four-year follow-up study with use of a precoated femoral stem

被引:80
|
作者
Leopold, SS [1 ]
Berger, RA [1 ]
Rosenberg, AG [1 ]
Jacobs, JJ [1 ]
Quigley, LR [1 ]
Galante, JO [1 ]
机构
[1] Rush Presbyterian St Lukes Med Ctr, Dept Orthopaed Surg, Chicago, IL 60612 USA
来源
关键词
D O I
10.2106/00004623-199908000-00004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Cancellous impaction allografting with cement for revision of the femoral component has conventionally been performed with a polished, tapered implant, which was designed to allow subsidence of the component. However, subsidence has been associated with pain in the thigh, dislocation of the hip, and revision of the component, This prospective study tested the hypothesis that good clinical results can be achieved - without subsidence of the component - with use of impaction allografting and a precoated, collared, straight stem for difficult femoral revisions. Methods: Twenty-nine patients had revision of the femoral component with use of impaction allografting with cement and a Harris Precoat stem. Impaction allografting was performed when loss of metaphyseal and diaphyseal bone precluded revision with more straightforward techniques or when reconstitution of bone was considered a specific goal of the reconstruction (as was sometimes the case with revision of the component in younger patients), The patients were followed prospectively and were evaluated with use of the Harris hip score and serial radiographs. The patients were followed for a minimum of four years (mean, sixty-three mouths), except for four who died. Results: Four patients died before the minimum four-year follow-np period had elapsed; all four had the prosthesis in place at the time of death. The Harris hip scores improved from a preoperative mean of 54 points (poor) (range, 21 to 91 points) to a mean of 87 points (good) (range, 41 to 100 paints) at the time of the most recent follow-up. Kaplan-Meier survivorship analysis, with aseptic loosening as the end point, was 92 percent (95 percent confidence interval, 82 to 100 percent) at six years; one additional hip failed because of a hematogenous infection at seventy-three months postoperatively, for an overall failure rate of 12 percent (three of twenty-five patients) at the time of the most recent follow-up, Two hips needed a repeat revision; one was revised because of subsidence of the stem with recurrent osteolysis and the other, in a patient who had hemodialysis, because of late sepsis.. A third femoral component subsided and failed but was not revised. Radiographic evidence of bone-stock reconstitution was observed in six (29 percent) of the twenty-one patients for whom radiographs were available; As in other series of patients managed with impaction allografting, the complication rate was high; excluding the revisions, three reoperations were performed, and six patients had either intraoperative femoral fracture or perforation necessitating cerclage wiring or cortical strut allografting: and cerclage wiring at the time of the procedure, There were six nonunions in eighteen patients who had been operated on with a transtrochanteric approach. Conclusions Difficult revisions of the femoral component with use of impaction allografting and a precoated stem provided satisfactory clinical and radiographic results at the time of intermediate-term follow-up. However, the high rate of complications in our series led us to refine our indications for the procedure.
引用
收藏
页码:1080 / 1092
页数:13
相关论文
共 50 条
  • [1] Revision of the femoral prosthesis with impaction allografting an a Charnley stem -: A 2-to 12-year follow-up
    Piccaluga, F
    Della Valle, AG
    Fernández, JCE
    Pusso, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (04): : 544 - 549
  • [2] Impaction allograft with cement for the revision of the femoral component. A minimum 39-month follow-up study with the use of the Exeter stem in Asian hips
    Soo-Jae Yim
    Min-Young Kim
    Yoo-Sung Suh
    International Orthopaedics, 2007, 31 : 297 - 302
  • [3] Impaction allografting with cement for extensive femoral bone loss in revision hip surgery - A 4-to 8-year follow-up study
    Fetzer, GB
    Callaghan, JJ
    Templeton, JE
    Goetz, DD
    Sullivan, PM
    Johnston, RC
    JOURNAL OF ARTHROPLASTY, 2001, 16 (08): : 195 - 202
  • [4] Impaction bone-grafting before insertion of a femoral stem with cement in revision total hip arthroplasty - A minimum two-year follow-up study
    Meding, JB
    Ritter, MA
    Keating, EM
    Faris, PM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (12): : 1834 - 1841
  • [5] Comment to the article “Impaction allograft with cement for the revision of the femoral component. A minimum 39-month follow-up study (SJ Yim et al.)”
    Anthony J. Hall
    International Orthopaedics, 2007, 31 : 419 - 419
  • [7] Exchange impaction allografting for femoral revision hip arthroplasty - Results in 87 cases after 3.6 years' follow-up
    Lind, M
    Krarup, N
    Mikkelsen, S
    Horlyck, E
    JOURNAL OF ARTHROPLASTY, 2002, 17 (02): : 158 - 164
  • [8] Cement-in-cement femoral component revision in the multiply revised total hip arthroplasty RESULTS WITH A MINIMUM FOLLOW-UP OF FIVE YEARS
    Sandiford, N. A.
    Jameson, S. S.
    Wilson, M. J.
    Hubble, M. J. W.
    Timperley, A. J.
    Howell, J. R.
    BONE & JOINT JOURNAL, 2017, 99B (02): : 199 - 203
  • [9] Revision total hip replacement with a cemented long femoral component: minimum 9-year follow-up results
    So, Kazutaka
    Kuroda, Yutaka
    Matsuda, Shuichi
    Akiyama, Haruhiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (06) : 869 - 874
  • [10] Revision total hip replacement with a cemented long femoral component: minimum 9-year follow-up results
    Kazutaka So
    Yutaka Kuroda
    Shuichi Matsuda
    Haruhiko Akiyama
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 869 - 874