Accuracy and Precision in Camera-Based Fluorescence Correlation Spectroscopy Measurements

被引:55
|
作者
Sankaran, Jagadish [1 ,2 ,3 ,4 ]
Bag, Nirmalya [2 ,3 ]
Kraut, Rachel Susan [4 ]
Wohland, Thorsten [1 ,2 ,3 ]
机构
[1] Singapore MIT Alliance, Singapore 117576, Singapore
[2] Natl Univ Singapore, Ctr BioImaging Sci, Dept Biol Sci, Singapore 117546, Singapore
[3] Natl Univ Singapore, Ctr BioImaging Sci, Dept Chem, Singapore 117546, Singapore
[4] Nanyang Technol Univ, Sch Biol Sci, Singapore 637551, Singapore
关键词
STANDARD-DEVIATION; CROSS-CORRELATION; BAYESIAN-APPROACH; DIFFUSION; FCS; SIMULATIONS; RESOLUTION; TRANSPORT; NOISE; CCD;
D O I
10.1021/ac303485t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Imaging fluorescence correlation spectroscopy (FCS) performed using array detectors has been successfully used to quantify the number, mobility, and organization of biomolecules in cells and organisms. However, there have not been any systematic studies on the errors in these estimates that are introduced due to instrumental and experimental factors. State-of-the-art array detectors are still restricted in the number of frames that can be recorded per unit time, sensitivity and noise characteristics, and the total number of frames that can be realistically recorded. These limitations place constraints on the time resolution, the signal-to-noise ratio, and the total measurement time, respectively. This work addresses these problems by using a combination of simulations and experiments on lipid bilayers to provide characteristic performance parameters and guidelines that govern accuracy and precision of diffusion coefficient and concentration measurements in camera-based FCS. We then proceed to demonstrate the effects of these parameters on the capability of camera-based FCS to determine membrane heterogeneity via the FCS diffusion laws, showing that there is a lower length scale limit beyond which membrane organization cannot be detected and which can be overcome by choosing suitable experimental parameters. On the basis of these results, we provide guidelines for an efficient experimental design for camera-based FCS to extract information on mobility, concentration, and heterogeneity.
引用
收藏
页码:3948 / 3954
页数:7
相关论文
共 50 条
  • [21] Camera-based colour inspection
    Nobbs, J.H.
    Connolly, C.
    Sensor Review, 2000, 20 (01) : 14 - 19
  • [22] Integrated camera-based navigation
    Hafskjold, BH
    Jalving, B
    Hagen, PE
    Gade, K
    JOURNAL OF NAVIGATION, 2000, 53 (02): : 237 - 245
  • [23] In vivo ultrasound-switchable fluorescence imaging using a camera-based system
    Yu, Shuai
    Yao, Tingfeng
    Liu, Yang
    Yuan, Baohong
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (03): : 1517 - 1538
  • [24] Camera-based optical palpation
    Sanderson, Rowan W.
    Fang, Qi
    Curatolo, Andrea
    Adams, Wayne
    Lakhiani, Devina D.
    Ismail, Hina M.
    Foo, Ken Y.
    Dessauvagie, Benjamin F.
    Latham, Bruce
    Yeomans, Chris
    Saunders, Christobel M.
    Kennedy, Brendan F.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [25] Influence of the surface hydrophobicity on Fluorescence Correlation Spectroscopy measurements
    Boutin, Celine
    Jaffiol, Rodolphe
    Plain, Jerome
    Royer, Pascal
    ULTRASENSITIVE AND SINGLE-MOLECULE DETECTION TECHNOLOGIES II, 2007, 6444
  • [26] Diffusion Measurements of Swimming Enzymes with Fluorescence Correlation Spectroscopy
    Guenther, Jan-Philipp
    Boersch, Michael
    Fischer, Peer
    ACCOUNTS OF CHEMICAL RESEARCH, 2018, 51 (09) : 1911 - 1920
  • [27] Characterization of the Surface Contribution to Fluorescence Correlation Spectroscopy Measurements
    Chowdhury, Salina A.
    Lim, Manho
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2011, 32 (02) : 583 - 589
  • [28] Camera-Based Light Emitter Localization Using Correlation of Optical Pilot Sequences
    Rahman, Md Rashed
    Sethuraman, T., V
    Gruteser, Marco
    Dana, Kristin J.
    Jain, Shubham
    Mandayam, Narayan B.
    Ashok, Ashwin
    IEEE ACCESS, 2022, 10 : 24368 - 24382
  • [29] The Benefit of Distraction: Denoising Camera-Based Physiological Measurements using Inverse Attention
    Nowara, Ewa M.
    McDuff, Daniel
    Veeraraghavan, Ashok
    2021 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV 2021), 2021, : 4935 - 4944
  • [30] Modeling photoplethysmographic signals in camera-based perfusion measurements: optoelectronic skin phantom
    Paul, Michael
    Mota, Filipa
    Antink, Christoph Hoog
    Blazek, Vladimir
    Leonhardt, Steffen
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (09) : 4353 - 4368