Hand-Portable Gas Chromatograph-Toroidal Ion Trap Mass Spectrometer (GC-TMS) for Detection of Hazardous Compounds

被引:197
|
作者
Contreras, Jesse A. [1 ]
Murray, Jacolin A. [1 ]
Tolley, Samuel E. [2 ]
Oliphant, Joseph L. [2 ]
Tolley, H. Dennis [1 ]
Lammert, Stephen A. [1 ]
Lee, Edgar D. [2 ]
Later, Douglas W. [2 ]
Lee, Milton L. [1 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
[2] Tor Technol, Amer Fork, UT USA
关键词
D O I
10.1016/j.jasms.2008.06.022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel gas chromatograph-mass spectrometer (GC-MS) based on a miniature toroidal ion trap mass analyzer (TMS) and a low thermal mass GC is described. The TMS system has an effective mass/charge (m/z) range of 50-442 with mass resolution at full-width half-maximum (FWHM) of 0.55 at m/z 91 and 0.80 at m/z 222. A solid-phase microextraction (SPME) fiber mounted in a simple syringe-style holder is used for sample collection and introduction into a specially designed low thermal mass GC injection port. This portable GC-TMS system weighs <13 kg (28 lb), including batteries and helium carrier gas cartridge, and is totally self-contained within dimensions of 47 X 36 X 18 cm (18.5 X 14 X 7 in.). System start-Lip takes about 3 min and sample analysis with library matching typically takes about 5 min, including time for column cool-down. Peak power consumption during sample analysis is about 80 W. Battery power and helium supply cartridges allow 50 and 100 consecutive analyses, respectively. Both can be easily replaced. An on-board library of target analytes is used to provide detection and identification of chemical compounds based on their characteristic retention times and mass spectra. The GC-TMS can detect 200 pg of methyl salicylate on-column. n-Butylbenzene and naphthalene can be detected at a concentration of 100 ppt in water from solid-phase microextraction (SPME) analysis of the headspace. The GC-TMS system has been designed to easily make measurements in a variety of complex and harsh environments. (J Am Soc Mass Spectrom 2008, 19, 1425-1434) (C) 2008 American Society for Mass Spectrometry
引用
收藏
页码:1425 / 1434
页数:10
相关论文
共 39 条
  • [21] Development of a proton-transfer reaction ion trap mass spectrometer: Online detection and analysis of volatile organic compounds
    Steeghs, M. M. L.
    Sikkens, C.
    Crespo, E.
    Cristescu, S. M.
    Harren, F. J. M.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 262 (1-2) : 16 - 24
  • [22] Rapid detection of volatile organic compounds in the subsurface by membrane introduction into a direct sampling ion-trap mass spectrometer
    Costanza, J
    Davis, WM
    FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 2000, 4 (05): : 246 - 254
  • [24] EVALUATION OF A THERMAL-DESORPTION GAS-CHROMATOGRAPH MASS-SPECTROMETER - ON-SITE DETECTION OF POLYCHLORINATED-BIPHENYLS AT A HAZARDOUS-WASTE SITE
    ROBBAT, A
    LIU, TY
    ABRAHAM, BM
    ANALYTICAL CHEMISTRY, 1992, 64 (04) : 358 - 364
  • [25] Characterization of automated solid phase micro-extraction (SPME) with GC-Toroidal ion trap mass spectrometry for detection of CWA simulants
    Riegner, Dawn E.
    Swayze, Michael D.
    Lachance, Zachary T.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [26] Determination of trace levels of taste and odor compounds in water by microextraction and gas chromatography ion trap detection mass spectrometry
    Bao, ML
    Barbieri, K
    Burrini, D
    Griffini, O
    Pantani, F
    WATER RESEARCH, 1997, 31 (07) : 1719 - 1727
  • [27] Direct Analysis of Organic Compounds in Liquid Using a Miniature Photoionization Ion Trap Mass Spectrometer with Pulsed Carrier-Gas Capillary Inlet
    Lu, Xinqiong
    Yu, Quan
    Zhang, Qian
    Ni, Kai
    Qian, Xiang
    Tang, Fei
    Wang, Xiaohao
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (08) : 1702 - 1708
  • [28] Analysis of volatile organic compounds, using the purge and trap injector coupled to a gas chromatograph/ion-trap mass spectrometer: Review of the results in Dutch surface water of the Rhine, Meuse, Northern Delta Area and Westerscheldt, over the period 1992-1997
    Miermans, CJH
    van der Velde, LE
    Frintrop, PCM
    CHEMOSPHERE, 2000, 40 (01) : 39 - 48
  • [29] Portable Digital Linear Ion Trap Mass Spectrometer Based on Separate-Region Corona Discharge Ionization Source for On-Site Rapid Detection of Illegal Drugs
    Li, Lingfeng
    Zhang, Tianyi
    Wang, Deting
    Zhang, Yunjing
    He, Xingli
    Wang, Xiaozhi
    Li, Peng
    MOLECULES, 2022, 27 (11):
  • [30] Determination of trace levels of taste and odor compounds in water by microextraction and gas chromatography-ion-trap detection-mass spectrometry
    Univ of Florence, Florence, Italy
    Water Res, 7 (1719-1727):