Hand-Portable Gas Chromatograph-Toroidal Ion Trap Mass Spectrometer (GC-TMS) for Detection of Hazardous Compounds

被引:197
|
作者
Contreras, Jesse A. [1 ]
Murray, Jacolin A. [1 ]
Tolley, Samuel E. [2 ]
Oliphant, Joseph L. [2 ]
Tolley, H. Dennis [1 ]
Lammert, Stephen A. [1 ]
Lee, Edgar D. [2 ]
Later, Douglas W. [2 ]
Lee, Milton L. [1 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
[2] Tor Technol, Amer Fork, UT USA
关键词
D O I
10.1016/j.jasms.2008.06.022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel gas chromatograph-mass spectrometer (GC-MS) based on a miniature toroidal ion trap mass analyzer (TMS) and a low thermal mass GC is described. The TMS system has an effective mass/charge (m/z) range of 50-442 with mass resolution at full-width half-maximum (FWHM) of 0.55 at m/z 91 and 0.80 at m/z 222. A solid-phase microextraction (SPME) fiber mounted in a simple syringe-style holder is used for sample collection and introduction into a specially designed low thermal mass GC injection port. This portable GC-TMS system weighs <13 kg (28 lb), including batteries and helium carrier gas cartridge, and is totally self-contained within dimensions of 47 X 36 X 18 cm (18.5 X 14 X 7 in.). System start-Lip takes about 3 min and sample analysis with library matching typically takes about 5 min, including time for column cool-down. Peak power consumption during sample analysis is about 80 W. Battery power and helium supply cartridges allow 50 and 100 consecutive analyses, respectively. Both can be easily replaced. An on-board library of target analytes is used to provide detection and identification of chemical compounds based on their characteristic retention times and mass spectra. The GC-TMS can detect 200 pg of methyl salicylate on-column. n-Butylbenzene and naphthalene can be detected at a concentration of 100 ppt in water from solid-phase microextraction (SPME) analysis of the headspace. The GC-TMS system has been designed to easily make measurements in a variety of complex and harsh environments. (J Am Soc Mass Spectrom 2008, 19, 1425-1434) (C) 2008 American Society for Mass Spectrometry
引用
收藏
页码:1425 / 1434
页数:10
相关论文
共 39 条
  • [1] Hand-Portable Gas Chromatograph-Toroidal Ion Trap Mass Spectrometer (GC-TMS) for Detection of Hazardous Compounds
    Contreras, Jesse A.
    Murray, Jacolin A.
    Tolley, Samuel E.
    Oliphant, Joseph L.
    Tolley, H. Dennis
    Lammert, Stephen A.
    Lee, Edgar D.
    Later, Douglas W.
    Lee, Milton L.
    1600, Elsevier Inc. (19):
  • [2] A hand-portable digital linear ion trap mass spectrometer
    Xue, Bing
    Sun, Lulu
    Huang, Zhengxu
    Gao, Wei
    Fan, Rongrong
    Cheng, Ping
    Ding, Li
    Ma, Li
    Zhou, Zhen
    ANALYST, 2016, 141 (19) : 5535 - 5542
  • [3] Use of a hand-portable gas chromatograph-toroidal ion trap mass spectrometer for self-chemical ionization identification of degradation products related to O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX)
    Smith, Philip A.
    Lepage, Carmela R. Jackson
    Savage, Paul B.
    Bowerbank, Christopher R.
    Lee, Edgar D.
    Lukacs, Michael J.
    ANALYTICA CHIMICA ACTA, 2011, 690 (02) : 215 - 220
  • [4] Miniaturized system of a gas chromatograph coupled with a Paul ion trap mass spectrometer
    Shortt, BJ
    Darrach, MR
    Holland, PM
    Chutjian, A
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (01): : 36 - 42
  • [5] Extraction and Identification of Volatile organic Compounds from Water in 70 s using SPME and a Hand Portable GC-TMS
    Bowerbank, Christopher R.
    Wirth, Tiffany C.
    Later, Douglas W.
    LC GC NORTH AMERICA, 2009, : 24 - 24
  • [6] Development of a portable gas chromatography linear ion trap mass spectrometer (GC-LIT-MS) for VOCs analysis in water
    Qiu, Junwei
    Xu, Kai
    Zhang, Tao
    Zhu, Huijun
    Zhang, Shuo
    Lu, Xinxin
    Li, Xiaoxu
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2024, 497
  • [7] Extraction of individual component spectra in gas chromatograph coupled with ion trap mass spectrometer by principle component analysis
    Su Yue
    Liao Yuan-Xi
    Guo Yin-Long
    ACTA CHIMICA SINICA, 2007, 65 (14) : 1377 - 1380
  • [8] Person-portable gas chromatography-toroidal ion trap mass spectrometry analysis of coffee bean volatile organic compounds
    Herron, Riley
    Lipphardt, Anna
    Euler, Luisa
    Nolvachai, Yada
    Marriott, Philip J.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2022, 473
  • [9] Miniaturized system of a gas chromatograph coupled with a Paul ion trap mass spectrometer (vol 40, pg 36, 2005)
    Shortt, BJ
    Darrach, MR
    Holland, PM
    Chutjian, A
    JOURNAL OF MASS SPECTROMETRY, 2005, 40 (04): : 549 - 549
  • [10] Methanol Detection in Transformer Oils using Gas Chromatography and Ion Trap Mass Spectrometer
    Matharage, S. Y.
    Liu, Q.
    Davenport, E.
    Wilson, G.
    Walker, D.
    Wang, Z. D.
    PROCEEDINGS OF THE 2014 IEEE 18TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL 2014), 2014,